Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1098 · Folder 191

SCREEN DETAILS IN LOBBY — DOORS & END WALLS

Sheet W217

Extraction: Reviewed · extraction partial. Verify the printed leaf width, door height, leaf count, push-bar count, dimension endpoints, and local material labels for the central paired glazed-metal doors in W217 Bay P without inferring profiles, concealed hardware, threshold construction, or world placement. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays. Normalized from an existing text re-audit; this import did not reopen the source image. Partial timed visual review: Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement. Partial timed visual review: Bay P directory construction and local witnesses

Highlighted reading: 31. Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.

Show every recorded property on this drawing →

Unresolved extraction work
  • W217-bay-p-null-operating-clear-width: The drawing prints two leaf-width segments, not a clear-opening dimension; swing/open position and stops are not established.
  • W217-bay-p-null-operating-clear-height: The 7'-6" value is retained by its drawn floor-to-door-head endpoints and is not relabeled operating clear height.
  • W217-bay-p-null-rough-opening: No rough-opening dimension or concealed wall/frame limit is printed in the inspected elevation.
  • W217-bay-p-null-profiles: The elevation shows the composition but does not provide securely assigned section profiles or fabrication dimensions.
  • W217-bay-p-null-glass-thickness: CLEAR PLATE GLASS is printed, but thickness, treatment, edge condition, and safety classification are not securely specified in the inspected region.
  • W217-bay-p-null-hardware: Only the printed METAL PUSH BARS and their drawn count are secure. Other hardware types, models, dimensions, and locations are not securely assigned.
  • W217-bay-p-null-push-bar-profile: The elevation securely establishes the count and metal material family, but not bar section, projection, fastening, or a dimension explicitly tied to mounting height.
  • W217-bay-p-null-threshold: No securely readable threshold note or section is assigned to the Bay P central door pair in IMG_1098.
  • W217-bay-p-null-swing: The selected source is an elevation; no securely assigned plan swing arcs were inspected.
  • W217-bay-p-null-world-placement: The Bay P elevation has not been registered to accepted W3 wall coordinates.
  • Complete drawing-note transcription
  • Every dimension and bay placement
  • Detailed hardware/fastener schedule
  • Exact cross-sheet bay correspondence
  • Cross-photo physical deduplication
  • Complete surviving-object inventory
  • Exact dimensions
  • Construction/alteration chronology
  • Condition assessment
  • P-6 component extraction
  • Installed fixture schedule and positions
  • As-built correspondence
  • Fixture finish and glass color
  • Fine fractions, witness endpoint classification, and remaining note transcription require targeted crop review
  • Companion/revision authority and installed room/floor registration remain outstanding
  • Modeling and whole-building acceptance checks not performed
  • Installed instance quantity, floor/room registration, physical transforms and as-built correspondence remain unresolved.
  • All uninspected regions, remaining notes/fractions/profiles, companion details and historical revision authority remain open.
  • Whole-building architectural acceptance has not been performed.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. The gold outline locates the selected reading. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

18 matching objects

An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.

assembly · f1-public-lobby-w217-bay-p-end-wall-assemblyModeling: not-modeled

W217 Bay P lobby end-wall assembly

Research representation: none. Architectural checks: pending.

First floor

22 recorded properties

Still to extract or check
  • Complete physical geometry
  • Accepted world placement
  • Cross-sheet registration
  • Overall Bay P run; report's roughly 24'-10" reading is not promoted to exact
  • Accepted wall placement
  • Minor offsets and ornament profiles
Inspect this object’s readings →

View source IMG_1098 ↗

fitting · f1-public-lobby-w217-bay-p-directoryModeling: not-modeled

W217 Bay P directory

Research representation: none. Architectural checks: pending.

First floor

3 recorded properties

Still to extract or check
  • Complete physical geometry
  • Accepted world placement
  • Cross-sheet registration
  • Exact width; report says about 3'-6"
  • Height and depth
  • Letter-board internal construction
  • Hardware dimensions
Inspect this object’s readings →

View source IMG_1098 ↗

opening · f1-public-lobby-w217-bay-p-elevator-no2-entranceModeling: not-modeled

W217 Bay P Elevator No. 2 entrance

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

11 recorded properties · Room f1-room-public-lobby

Still to extract or check
  • Complete physical geometry
  • Accepted physical world placement
  • Cross-sheet registration
  • Operating clear opening
  • Rough opening
  • Leaf travel
Inspect this object’s readings →

View source IMG_1098 ↗

paired-door · f1-public-lobby-w217-bay-p-door-pairModeling: not-modeled

Bay P central paired glazed-metal doors

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

33 recorded properties

Still to extract or check
  • Operating clear width and height
  • Rough opening width and height
  • Leaf, stile, rail, muntin, and frame section profiles
  • Glass thickness, treatment, edge condition, and safety classification
  • Push-bar section, diameter, projection, attachment, and exact mounting elevation
  • Hinges, pivots, closers, pulls, locks, latches, stops, and fasteners
  • Threshold material, section, dimensions, anchorage, and floor transition
  • Door swing direction and opening angle
  • Accepted physical world placement
  • Glass thickness
  • Stile/rail profiles
  • Pivot/closer models
  • Threshold section
  • Accepted world transform
Inspect this object’s readings →

View source IMG_1098 ↗

room-assembly · f1-public-lobby-architectural-envelopeModeling: not-modeled

First-floor public postal lobby architectural envelope

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

4 recorded properties

Still to extract or check
  • Controlling lobby ceiling height because 18'-3" and 18'-9" readings conflict
  • Accepted wall-bay positions and widths
  • Coffer-panel dimensions and exact motif assignment
  • Cornice and beam profiles
  • As-built deviations and alteration chronology
Inspect this object’s readings →

View source IMG_1202 ↗

assembly-system · f1-public-lobby-postal-wall-systemModeling: not-modeled

Continuous public postal service and lockbox wall system

Research representation: none. Architectural checks: pending.

First floor

Source relationships · not a verified physical connection

1 recorded properties

Still to extract or check
  • Complete bay-by-bay sequence and correspondence between drawing bays and surviving 1983 modules
  • Original installed lockbox and depository quantities
  • Individual box sizes, row/column counts and numbering ranges
  • Module widths, heights, depths and corner-return geometry
  • Exact staff-side casework dimensions
  • As-built phase of plain/infilled panels
Inspect this object’s readings →

View source IMG_1202 ↗

wall-clock · f1-public-lobby-w217-bay-p-clockModeling: not-modeled

Bay P wall clock

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Clock diameter
  • Face material and color
  • Movement
  • Mounting depth
  • Correspondence to distant clock-like fitting in HABS 13
Inspect this object’s readings →

View source IMG_1095 ↗

paired-door-type · type-w217-bay-p-glazed-door-pairModeling: not-modeled

W-217 Bay P central paired glazed-metal doors

Research representation: none. Architectural checks: pending.

First floor · Original mark: P

0 recorded properties

Still to extract or check
  • Complete measured geometry
  • Verified installed instances
  • Accepted building placement
  • As-built correspondence
Inspect this object’s readings →

View source IMG_1095 ↗

directory-case-type · type-w217-bay-p-directoryModeling: not-modeled

W-217 Bay P bronze-framed DIRECTORY case

Research representation: none. Architectural checks: pending.

First floor · Original mark: DIRECTORY

0 recorded properties

Still to extract or check
  • Complete measured geometry
  • Verified installed instances
  • Accepted building placement
  • As-built correspondence
Inspect this object’s readings →

View source IMG_1095 ↗

wall-clock-type · type-w217-bay-p-clockModeling: not-modeled

W-217 Bay P wall clock with separate metal Roman numerals and hands

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Complete measured geometry
  • Verified installed instances
  • Accepted building placement
  • As-built correspondence
Inspect this object’s readings →

View source IMG_1095 ↗

assembly-system · postal-workroom-casework-system-unextractedModeling: not-modeled

Postal workroom staff-side casework system — extraction pending

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Measured boundary
  • Complete contents
  • World placement
  • Cross-sheet coordination
Inspect this object’s readings →

View source IMG_1202 ↗

room-zone · registry-box-parcel-post-alcovesModeling: not-modeled

Registry, box and parcel-post alcove group

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Measured boundary
  • Complete contents
  • World placement
  • Cross-sheet coordination
Inspect this object’s readings →

View source IMG_1202 ↗

room-zone · lockbox-zoneModeling: not-modeled

Public lobby lockbox zone

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Measured boundary
  • Complete contents
  • World placement
  • Cross-sheet coordination
Inspect this object’s readings →

View source IMG_1202 ↗

room-zone · staffed-service-and-depository-zoneModeling: not-modeled

Public lobby staffed-service and depository zone

Research representation: none. Architectural checks: pending.

First floor

0 recorded properties

Still to extract or check
  • Measured boundary
  • Complete contents
  • World placement
  • Cross-sheet coordination
Inspect this object’s readings →

View source IMG_1202 ↗

material · material-postal-screen-plate-glassModeling: not-modeled

Plate glass in postal and door-screen assemblies

Research representation: none. Architectural checks: pending.

First floor

1 recorded properties

Still to extract or check
  • Thickness
  • Safety treatment
  • Replacement chronology
  • Exact clear/obscure assignment outside explicitly described details
Inspect this object’s readings →

View source IMG_1090 ↗

assembly · parallel-img1098-directoryModeling: not-modeled

Bay P directory and adjoining trim

Research representation: none. Architectural checks: pending.

Floor assignment pending

12 recorded properties

Still to extract or check
  • Fine fractions, witness endpoint classification, and remaining note transcription require targeted crop review
  • Companion/revision authority and installed room/floor registration remain outstanding
  • Modeling and whole-building acceptance checks not performed
Inspect this object’s readings →

View source IMG_1098 ↗

View all source photographs →