Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
control-w400-interior-68-82verified · printed
perimeter.span.C10.C11
14′0″14 ft
Printed perimeter-support span. This does not itself dimension an interior support.
control-w400-interior-68-82verified · printed
perimeter.span.C11.C12
15′7″15.583333 ft
Printed perimeter-support span. This does not itself dimension an interior support.
control-w400-interior-68-82verified · printed
perimeter.span.C70.C72
14′0″14 ft
Printed perimeter-support span. This does not itself dimension an interior support.
control-w400-interior-68-82verified · printed
perimeter.span.C72.C84
14′0″14 ft
Printed perimeter-support span. This does not itself dimension an interior support.
control-w400-interior-68-82verified · printed
perimeter.span.C84.C96
22′7″22.583333 ft
Printed perimeter-support span. This does not itself dimension an interior support.
control-w400-interior-68-82unreviewed · observed
framing.observedLongitudinalIncidence
A connected, apparently straight beam/girder line passes through the drawn support symbols C10, C68, C82 and C94.Observed structural incidence, not a printed zero transverse offset. Only the endpoint/support identities C10/C68/C82/C94 are assigned; intermediate marks are not transcribed in this bounded task.
column-68unreviewed · observed
framing.observedTransverseIncidence
A connected transverse framing line runs through C68, C69 and C70.column-82unreviewed · observed
framing.observedTransverseIncidence
A connected transverse framing line runs through C82, C83 and C84.control-w400-interior-68-82verified · derived
perimeter.referenceX.C10.C94
78′7″ − 15′7″ − 14′0″ = 49′0″49 ft
Perimeter station only. C94 assignment reuses existing registered perimeter correspondence.
Calculated from: structural-registration-origin-half-span, interior-68-82-w400-x-10-11, interior-68-82-w400-x-11-12
control-w400-interior-68-82verified · derived
perimeter.referenceZ.C84
78′7″ − 22′7″ = 56′0″56 ft
Calculated from: structural-registration-origin-half-span, interior-68-82-w400-z-84-96
control-w400-interior-68-82verified · derived
perimeter.referenceZ.C70
78′7″ − 22′7″ − 14′0″ − 14′0″ = 28′0″28 ft
Calculated from: interior-68-82-w400-perimeter-z-84, interior-68-82-w400-z-70-72, interior-68-82-w400-z-72-84
column-68unreviewed · derived
coordinationCandidate.worldX
49′0″, conditional on zero column-center offset from the C10/C94 longitudinal framing line49 ft
Calculated from: interior-68-82-w400-perimeter-x-station, interior-68-82-w402-perimeter-x-station, interior-68-82-w400-longitudinal-framing-incidence, interior-68-82-w402-longitudinal-framing-incidence, assumption-interior-longitudinal-framing-line-equals-column-control
column-68unreviewed · derived
coordinationCandidate.worldZ
28′0″, conditional on zero column-center offset from the transverse C68/C70 framing line28 ft
Calculated from: interior-68-82-w400-perimeter-z-70, interior-68-82-w402-perimeter-z-70, interior-68-82-w400-transverse-68-70, interior-68-82-w402-transverse-68-70, assumption-column-68-transverse-line-equals-column-control
column-82unreviewed · derived
coordinationCandidate.worldX
49′0″, conditional on zero column-center offset from the C10/C94 longitudinal framing line49 ft
Calculated from: interior-68-82-w400-perimeter-x-station, interior-68-82-w402-perimeter-x-station, interior-68-82-w400-longitudinal-framing-incidence, interior-68-82-w402-longitudinal-framing-incidence, assumption-interior-longitudinal-framing-line-equals-column-control
column-82unreviewed · derived
coordinationCandidate.worldZ
56′0″, conditional on zero column-center offset from the transverse C82/C84 framing line56 ft
Calculated from: interior-68-82-w400-perimeter-z-84, interior-68-82-w400-transverse-82-84, interior-68-82-w402-transverse-82-84, assumption-column-82-transverse-line-equals-column-control
column-68unreviewed · inferred
Unaccepted framing incidence assumption
The connected longitudinal framing path through C10/C68/C82/C94 coincides with the exact column-control axis without an unmarked transverse offset.The drawn beam/girder line may describe a member line or framing connection rather than the exact center of an eccentrically connected column. Schematic one-line representations do not prove zero eccentricity.
column-68unreviewed · inferred
Unaccepted framing incidence assumption
Transverse framing line through C68 and perimeter C70 supplies the same Z control to both column centers.An eccentric attachment, unrecorded local center offset or schematic beam endpoint may differ from the actual column-control center.
column-82unreviewed · inferred
Unaccepted framing incidence assumption
Transverse framing line through C82 and perimeter C84 supplies the same Z control to both column centers.An eccentric attachment, unrecorded local center offset or schematic beam endpoint may differ from the actual column-control center.
bway-F4-horizontal-placement-gateverified · observed
Physical pilot horizontal placement gate
FAIL — no accepted plan/elevation horizontal controlThe Broadway elevation and section retain candidate controls for middle bay B05, but the previously cited W-6 Rooms 401-407 plan chain is on the east/Sixth Avenue side. It cannot attach B05 to a Broadway plan bay or provide an independent horizontal plan/elevation check.
bway-F4-horizontal-placement-gateunreviewed · derived
Candidate nominal B05 bay center station
-7 ft structural candidate-7 ft
The structural support stations are exact arithmetic, but the cited W-6 Rooms 401-407 chain is on Sixth Avenue rather than Broadway. A registered page-right/west W-6 chain with exact grid names is required before B05 can be assigned.
Calculated from: column-58-registered-world-z, column-52-registered-world-z
bway-F4-horizontal-placement-gateunreviewed · observed
Accepted opening host world X
UnresolvedNumeric value unresolved
The local middle-span exterior stone-face arithmetic is verified, but its attachment to opening-broadway-F4-B05 remains conditional, and W-6 does not register or classify that exterior face.
bway-F4-horizontal-placement-gateunreviewed · observed
Accepted opening station
UnresolvedNumeric value unresolved
All available comparisons are either numeric-only, same-sheet arithmetic, conditionally keyed, or use unlike endpoint classes. The normalized elevation registration still records horizontalIndependentCheckCount = 0 and full2dCheckRmsFeet = null.
column-8verified · derived
world X
printed perimeter column bay chain21 ft
Drawing elevation where applicable. verified-column-control; no finite C8/C9 strip or C12 placed pad is accepted.
column-8verified · derived
world Z
south/Madison outer-column line-78.583333 ft
Drawing elevation where applicable. verified-column-control; no finite C8/C9 strip or C12 placed pad is accepted.