Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1307 · Folder 187

BROADWAY FOYER — SIXTH STREET ENTRANCE — ELEVATOR CAB E — TYPICAL FLOOR ELEVATOR DOORS

Sheet W219

Extraction: Reviewed · extraction partial. Resolve W229's printed cross-reference for typical elevator doors and cab details, identify the exact archival source, and extract only securely printed or drawn local properties without transferring dimensions among elevator numbers, floors, shafts, platforms, or world coordinates. Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: Source-local regional inventory and bounded companion findings; architecture and exhaustive extraction unapproved.

Unresolved extraction work
  • W219-null-platform-width: No dimension on the reviewed region is printed as PLATFORM width; the 6'-8" and 6'-4" plan witnesses are not relabeled.
  • W219-null-platform-depth: No dimension is printed as PLATFORM depth; 4'-10 3/4" remains an outer cab-plan witness.
  • W219-null-cab-clear-width: The 6'-4" dimension is not labeled CLEAR and is not promoted to a clear dimension.
  • W219-null-cab-clear-depth: No printed clear-depth label or securely classified inner endpoint pair was found.
  • W219-null-cab-height: Small vertical dimension text could not be read securely enough for transcription.
  • W219-null-landing-door-width: No securely readable width with classified operating-clear endpoints was established.
  • W219-null-landing-door-height: The photographed dimension text/endpoints do not securely establish an operating-clear height.
  • W219-null-guide-rails: The printed BRONZE RAILING is a cab-interior handrail/railing, not a hoistway guide rail. No guide-rail section, size, spacing, bracket, or placement was printed in the reviewed W219 elevator regions.
  • W219-null-landing-sill-profile: The cab plan labels a BRONZE SILL, but that note is not transferred to the landing-door sill and no secure landing-sill profile was extracted.
  • W219-null-door-head: No securely readable printed head assembly specification or exact dimension was established.
  • W219-null-pit: W219's reviewed elevator regions contain door/cab architectural details, not a pit section.
  • W219-null-overhead: No overhead or top-clearance section is printed in the reviewed W219 elevator regions.
  • W219-null-machine-equipment: No machine, motor, sheave, governor, rope, controller, or power specification is printed in the reviewed W219 elevator regions.
  • W219-null-world-placement: No W219-to-W3 registration was attempted, and no photographed pixel distance was used as a physical measurement.
  • Text-only reuse of elevator report; clear geometry and installed registration questions need independent evidence.
  • Remaining uninspected notes, dimensions, schedules, details and companion sheets require separate review.
  • Original versus revision authority, installed instance correspondence and source-to-building registration remain unresolved.
  • No closed physical profile or architectural/model acceptance established.
  • Unmeasured curve radii, moulding endpoints and closed physical profiles remain null; photographic tracing is not a dimension.
  • Original versus revision authority, installed quantities and source-to-room/bay registration remain unresolved.
  • Companion details, fixing schedules, actual installed finishes and as-built correspondence remain open.
  • No floor assignment inferred for generic cornice/grille details from adjacent views.
  • Remaining dimensions, fine fractions, notes, schedules and companion details are not exhaustively extracted.
  • Installed quantities, accepted room/bay placement and source-to-building registration remain unresolved.
  • Original/revision authority, actual finish and physical profile applicability remain unresolved; modeling/checking unchecked.
  • South-wall small chain fractions and complete envelope remain unextracted. No elevator-clear dimensions, cab height, pit, overhead, machine or world-placement questions closed.
  • Remaining fine dimension fractions and witness endpoint classes require targeted master crops; standard inventory does not certify exhaustive extraction.
  • All notes, material-code keys, schedules, approval/date/revision fields and companion references need complete transcription and reconciliation.
  • Exact installed quantities, room/bay placement, source-to-building registration, physical layer/profiles and as-built correspondence remain unresolved.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

54 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

type-W219-typical-landing-doorverified · printed

applicability

TYPICAL FOR ALL OPENINGS TO ELEVATOR #3; FOR BASEMENT OPENINGS TO ELEVATORS #1 & #2; & FOR ALL OPENINGS ABOVE FIRST FLOOR TO ELEVATORS #1 & #2 UNLESS OTHERWISE SHOWN.

Printed relational scope only; floor IDs are not expanded from this sheet. landing-door type only Authoring eligibility: eligible-only-with-the-printed-elevator-and-floor-scope.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FOR ALL OPENINGS TO ELEVATOR #3; FOR BASEMENT OPENINGS TO ELEVATORS #1 & #2; & FOR ALL OPENINGS ABOVE FIRST FLOOR TO ELEVATORS #1 & #2 UNLESS OTHERWISE SHOWN.

type-W219-typical-landing-doorverified · observed

leaf_count

Two door leaves drawn in the typical elevation

2 count

per W219-landing-door-applicability type-W219-typical-landing-door Authoring eligibility: eligible-local-type-composition.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: Two door leaves drawn in the typical elevation

type-W219-typical-landing-doorverified · observed

recessed_square_panel_count_per_leaf

Five square recessed/relief panels drawn vertically on each leaf

5 count

per W219-landing-door-applicability each of the two landing-door leaves Authoring eligibility: eligible-local-type-composition.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: Five square recessed/relief panels drawn vertically on each leaf

type-W219-typical-landing-doorverified · printed

door_material

METAL ELEVATOR DOORS

per W219-landing-door-applicability landing-door leaves Authoring eligibility: eligible-material-only.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: METAL ELEVATOR DOORS

type-W219-typical-landing-doorverified · printed

trim_material

METAL TRIM

per W219-landing-door-applicability typical landing-door surround Authoring eligibility: eligible-material-only.

type-W219-typical-landing-doorverified · printed

plinth_material

MARBLE PLINTH

per W219-landing-door-applicability typical landing-door surround Authoring eligibility: eligible-material-only.

type-W219-metal-cab-planverified · printed

applicability

TYPICAL FOR ELEVATORS 1 & 2 & 3

cab plan only Authoring eligibility: eligible-for-plan-properties-only.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FOR ELEVATORS 1 & 2 & 3

type-W219-metal-cab-planverified · printed

outer_horizontal_plan_witness

6'-8"

6.666667 ft

The extension lines bound the outer plan envelope. The sheet does not name this value platform width, car clear width, or hoistway width. outer horizontal dimension line over the metal-cab plan Authoring eligibility: eligible-as-local-witness-only.

type-W219-metal-cab-planverified · printed

inner_horizontal_plan_witness

6'-4"

6.333333 ft

The value is retained as a distinct inner plan witness. It is not renamed cab clear width or platform width. inner horizontal dimension line over the metal-cab plan Authoring eligibility: eligible-as-local-witness-only.

type-W219-metal-cab-planverified · printed

left outer-to-inner horizontal side segment

2"

2 in

left and right horizontal chain segments between the 6'-8" and 6'-4" witnesses. Authoring eligibility: eligible-as-local-witness-only. The segment is not a wall or platform thickness.

type-W219-metal-cab-planverified · printed

right outer-to-inner horizontal side segment

2"

2 in

left and right horizontal chain segments between the 6'-8" and 6'-4" witnesses. Authoring eligibility: eligible-as-local-witness-only. The segment is not a wall or platform thickness.

type-W219-metal-cab-planverified · printed

outer_vertical_plan_witness

4'-10 3/4"

4.895833 ft

The value is not promoted to platform depth or inside-clear cab depth. right-side vertical dimension line at the cab body, excluding the separately chained front projection Authoring eligibility: eligible-as-local-witness-only.

type-W219-metal-cab-planverified · printed

floor_finish

[thickness unreadable] RUBBER TILE FLOOR

cab floor plan Authoring eligibility: eligible-material-only. Missing: Tile thickness.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: [thickness unreadable] RUBBER TILE FLOOR

type-W219-metal-cab-planverified · printed

ceiling_emergency_exit_presence

EMERGENCY EXIT

1 count

half ceiling plan Authoring eligibility: eligible-presence-only. Missing: Emergency-exit clear dimensions. Missing: Hinge, latch, and access direction.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: EMERGENCY EXIT

type-W219-metal-cab-planverified · printed

cab_sill_material

BRONZE SILL

cab entrance sill Authoring eligibility: eligible-material-only. Missing: Sill width, depth, profile, groove, and attachment.

type-W219-metal-cab-planverified · printed

cab_door_material

HOLLOW METAL CAB DOORS

cab doors in the metal-cab plan Authoring eligibility: eligible-material-only.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: HOLLOW METAL CAB DOORS

type-W219-cab-E-elevation-assemblyverified · printed

view_relationship

HALF REAR; HALF FRONT; FRONT & REAR ELEVATIONS OF ELEVATOR CABS; SIDE ELEVATIONS SIMILAR TO REAR

Cab E elevation assembly Authoring eligibility: eligible-local-composition-only.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: HALF REAR; HALF FRONT; FRONT & REAR ELEVATIONS OF ELEVATOR CABS; SIDE ELEVATIONS SIMILAR TO REAR

type-W219-cab-E-elevation-assemblyverified · printed

head_grille_material

CAST BRONZE GRILLE

cab elevation head/frieze grille Authoring eligibility: eligible-material-and-location-only.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: CAST BRONZE GRILLE

type-W219-cab-E-elevation-assemblyverified · printed

interior_railing_material

[size unreadable] BRONZE RAILING

This is an interior cab railing, not a hoistway guide rail. cab interior railing Authoring eligibility: eligible-material-only. Missing: Rail section size. Missing: Railing height. Missing: Exact return geometry.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: [size unreadable] BRONZE RAILING

type-W219-cab-E-elevation-assemblyverified · printed

railing_bracket_material

CAST BRONZE BRACKETS

cab interior railing brackets Authoring eligibility: eligible-material-only.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: CAST BRONZE BRACKETS

type-W219-cab-E-elevation-assemblyverified · printed

front_door_material

HOLLOW METAL DOOR

front half-elevation of Cab E Authoring eligibility: eligible-material-only.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: HOLLOW METAL DOOR

type-W219-metal-cab-planunreviewed · observed

platform_width

Unresolved

Numeric value unresolved

No dimension on the reviewed region is printed as PLATFORM width; the 6'-8" and 6'-4" plan witnesses are not relabeled.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

type-W219-metal-cab-planunreviewed · observed

platform_depth

Unresolved

Numeric value unresolved

No dimension is printed as PLATFORM depth; 4'-10 3/4" remains an outer cab-plan witness.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

type-W219-metal-cab-planunreviewed · observed

inside_clear_width

Unresolved

Numeric value unresolved

The 6'-4" dimension is not labeled CLEAR and is not promoted to a clear dimension.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

type-W219-metal-cab-planunreviewed · observed

inside_clear_depth

Unresolved

Numeric value unresolved

No printed clear-depth label or securely classified inner endpoint pair was found.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

type-W219-cab-E-elevation-assemblyunreviewed · observed

cab_height

Unresolved

Numeric value unresolved

Small vertical dimension text could not be read securely enough for transcription.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: HALF REAR; HALF FRONT; FRONT & REAR ELEVATIONS OF ELEVATOR CABS; SIDE ELEVATIONS SIMILAR TO REAR; CAST BRONZE GRILLE; BRONZE RAILING; CAST BRONZE BRACKETS; HOLLOW METAL DOOR

type-W219-typical-landing-doorunreviewed · observed

landing_door_clear_width

Unresolved

Numeric value unresolved

No securely readable width with classified operating-clear endpoints was established.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FLOOR ELEVATOR DOORS; METAL ELEVATOR DOORS; METAL TRIM; MARBLE PLINTH

type-W219-typical-landing-doorunreviewed · observed

landing_door_clear_height

Unresolved

Numeric value unresolved

The photographed dimension text/endpoints do not securely establish an operating-clear height.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FLOOR ELEVATOR DOORS; METAL ELEVATOR DOORS; METAL TRIM; MARBLE PLINTH

type-W219-hoistway-equipment-unresolvedunreviewed · observed

car_and_counterweight_guide_rails

Unresolved

The printed BRONZE RAILING is a cab-interior handrail/railing, not a hoistway guide rail. No guide-rail section, size, spacing, bracket, or placement was printed in the reviewed W219 elevator regions.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FLOOR ELEVATOR DOORS; METAL ELEVATOR DOORS; METAL TRIM; MARBLE PLINTH

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: HALF REAR; HALF FRONT; FRONT & REAR ELEVATIONS OF ELEVATOR CABS; SIDE ELEVATIONS SIMILAR TO REAR; CAST BRONZE GRILLE; BRONZE RAILING; CAST BRONZE BRACKETS; HOLLOW METAL DOOR

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

type-W219-typical-landing-doorunreviewed · observed

landing_sill_profile_and_dimensions

Unresolved

The cab plan labels a BRONZE SILL, but that note is not transferred to the landing-door sill and no secure landing-sill profile was extracted.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FLOOR ELEVATOR DOORS; METAL ELEVATOR DOORS; METAL TRIM; MARBLE PLINTH

type-W219-typical-landing-doorunreviewed · observed

landing_door_head_construction_and_dimensions

Unresolved

No securely readable printed head assembly specification or exact dimension was established.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FLOOR ELEVATOR DOORS; METAL ELEVATOR DOORS; METAL TRIM; MARBLE PLINTH

type-W219-hoistway-equipment-unresolvedunreviewed · observed

pit_depth_and_equipment

Unresolved

W219's reviewed elevator regions contain door/cab architectural details, not a pit section.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FLOOR ELEVATOR DOORS; METAL ELEVATOR DOORS; METAL TRIM; MARBLE PLINTH

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: HALF REAR; HALF FRONT; FRONT & REAR ELEVATIONS OF ELEVATOR CABS; SIDE ELEVATIONS SIMILAR TO REAR; CAST BRONZE GRILLE; BRONZE RAILING; CAST BRONZE BRACKETS; HOLLOW METAL DOOR

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

type-W219-hoistway-equipment-unresolvedunreviewed · observed

overhead_height_and_clearances

Unresolved

No overhead or top-clearance section is printed in the reviewed W219 elevator regions.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FLOOR ELEVATOR DOORS; METAL ELEVATOR DOORS; METAL TRIM; MARBLE PLINTH

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: HALF REAR; HALF FRONT; FRONT & REAR ELEVATIONS OF ELEVATOR CABS; SIDE ELEVATIONS SIMILAR TO REAR; CAST BRONZE GRILLE; BRONZE RAILING; CAST BRONZE BRACKETS; HOLLOW METAL DOOR

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

type-W219-hoistway-equipment-unresolvedunreviewed · observed

machine_and_drive_equipment

Unresolved

No machine, motor, sheave, governor, rope, controller, or power specification is printed in the reviewed W219 elevator regions.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: TYPICAL FLOOR ELEVATOR DOORS; METAL ELEVATOR DOORS; METAL TRIM; MARBLE PLINTH

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: HALF REAR; HALF FRONT; FRONT & REAR ELEVATIONS OF ELEVATOR CABS; SIDE ELEVATIONS SIMILAR TO REAR; CAST BRONZE GRILLE; BRONZE RAILING; CAST BRONZE BRACKETS; HOLLOW METAL DOOR

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

type-W219-metal-cab-planunreviewed · observed

world_placement

Unresolved

No W219-to-W3 registration was attempted, and no photographed pixel distance was used as a physical measurement.

IMG_1307 · sheet-W219 · Locate on drawing ↗

Drawing notation: PLAN OF METAL ELEVATOR CABS; TYPICAL FOR ELEVATORS 1 & 2 & 3; 6'-8"; 6'-4"; 2"; 2"; 4'-10 3/4"; RUBBER TILE FLOOR; EMERGENCY EXIT; BRONZE SILL; HOLLOW METAL CAB DOORS

lobbyprofiles1013q-w219-ceiling-grille-typeverified · printed

grille-material

CAST PLASTER GRILLE

Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.

IMG_1307 · W-219 · Locate on drawing ↗

Drawing notation: CAST PLASTER GRILLE

Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.

lobbyprofiles1013q-w219-ceiling-grille-typeverified · printed

screen-relationship

WALL SCREEN BEHIND

Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.

IMG_1307 · W-219 · Locate on drawing ↗

Drawing notation: WALL SCREEN BEHIND

Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.

lobbyprofiles1013q-w219-cornice-model47-typeverified · printed

model-mark

MODEL NO. 47

47 model-number

Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.

IMG_1307 · W-219 · Locate on drawing ↗

Drawing notation: MODEL NO. 47

Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.

lobbyprofiles1013q-w219-cornice-model47-typeverified · observed

complete-drawn-rosettes-in-cropped-view

Three complete rosettes visible in the bounded cornice view

3 drawn-detail-count

Three complete drawn motifs in this bounded source view, not installed quantity or full-run component count.

IMG_1307 · W-219 · Locate on drawing ↗

Drawing notation: Three complete rosettes visible in the bounded cornice view

Three complete drawn motifs in this bounded source view, not installed quantity or full-run component count.

lobbyprofiles1013q-w219-cornice-model47-typeverified · printed

drawing-scale

1½″ SCALE DETAIL OF CORNICE

Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.

IMG_1307 · W-219 · Locate on drawing ↗

Drawing notation: 1½″ SCALE DETAIL OF CORNICE

Printed source-local original photographic layer only. Endpoints remain those of the drawn witness; no operating-clear size, accepted world transform, installed count, revision equivalence or closed profile inferred.

View all source photographs →