464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1267 · Folder 189

DETAIL OF ELEVATOR NO. 2

Sheet W230

Extraction: Reviewed · extraction partial. Bounded first-floor elevator audit: DETAIL OF ELEVATOR NO. 2. First-floor Elevator No. 2 plan, column marks, axis order, clear-hatch labels and local offset witnesses. Elevator detail-to-W3 physical-placement gate: DETAIL OF ELEVATOR NO. 2. W230 first-floor Elevator 2 plan: Column 83-to-east-outside-enclosure-face witness, Column 83-to-east-clear-hatch-edge witness, printed 7-foot clear width and resulting world-X clear-hatch edge pair. Elevator-front bounded gate: Elevator 2 east enclosure face and one-axis clear-hatch controls. Partial timed visual review: Text-first OCR/queue/prior-package audit only; existing verified properties reused without duplication. Orientation not rechecked where null. Partial timed visual review: Text reuse only; no fresh pixel evidence or exhaustive-review claim.

Highlighted reading: +u = +X west/Broadway.

Show every recorded property on this drawing →

Unresolved extraction work
  • Accepted world wall faces and exact shaft polygons for all three elevators
  • Registered relationship between W229/W230/W231 detail coordinates and W3 world coordinates
  • Rough-versus-finished enclosure wall planes and wall thicknesses
  • W217 title-block confirmation and exact endpoint interpretation for the 3'-6" and 6'-9 3/4" door readings
  • Exact first-floor Elevator 3 door width, height, jamb/head/sill and rough opening
  • Readable Elevator 3 vertical hatch/shaft witness
  • Car/cab/platform sizes, rail/counterweight coordinates, pit depths and overhead clearances
  • Accepted ramp length, slope and threshold build-up at Elevator 3
  • Architecturally accepted reconciliation of all floor traces, especially the fourth-floor mechanical underlay
  • World-Z clear-hatch offsets, finite enclosure-face endpoints, wall thickness and physical construction remain unresolved.
  • For W229, the west outside enclosure face is fixed at world X = -65.020833 ft and the south/north clear-hatch edges are fixed at world Z = 46/56 ft; both clear-hatch world-X edges remain unresolved. For W230, the east outside enclosure face is fixed at X = 65.020833 ft and the clear-hatch east/west edges at X = 66.083333/73.083333 ft; both clear-hatch world-Z edges remain unresolved. Both elevators still lack finite enclosure-face endpoints, opposite faces, wall thickness and complete hatch-to-wall construction.
  • For W231, an exact non-collinear column/grid frame and a complete, classified shaft or clear-hatch width/depth chain.
  • Rough-face versus finish-face classification and wall thickness for each enclosure side.
  • Independently accepted matching W3 hatch or shaft faces and a reported hold-out corner residual.
  • Pit depth, overhead, slab opening and cross-floor continuation evidence for each elevator independently.
  • World wall plane and jamb-center/inside-jamb offsets for all three entrances.
  • Operating clear width and height, rough opening, leaf overlap/travel, sill, head and wall-thickness build-up.
  • Elevator 3 first-floor entrance dimensions and endpoint classes.
  • An independent check tying each local door centerline to the corresponding W3 landing wall.
  • Cab-to-hatch origin, platform size and inside-clear dimensions.
  • Guide-rail, counterweight and bracket centerlines tied to classified hatch faces.
  • Confirmed assignment of W219 Cab E elevations to Elevator 1, 2 or 3.
  • Door operator, travel/pocket and emergency-exit geometry.
  • Dimensioned horizontal extents and wall-face endpoints for the Elevator 1 vestibule and Elevator 2 Broadway foyer thresholds.
  • Elevator 3 ramp length, slope, threshold build-up and exact landing boundary at EL. 93.25 and EL. 95.33.
  • Registered sill/head coordinates and independent correspondence to W3 landing traces.
  • As-built confirmation before accepting vertical shaft or landing continuity.
  • North and south endpoints of the accepted outside enclosure face
  • World Z coordinates of both 10-foot clear-hatch edges
  • Enclosure wall thickness and opposite wall faces
  • Floor-opening construction, vertical extent, pit and overhead continuation
  • Complete physical shaft, door, cab and landing transforms
  • A readable first-floor W217 Section E or applicable companion section with front and back faces and exact profile/depth dimensions for one named component, plus complete width and height endpoints for that same component.
  • Printed or independently checked panel extents before any ornament panels are given physical sizes; retain panel instances without fabricated dimensions until then.
  • Classified first-floor host wall face, thickness and jamb/reveal/sill/head interfaces tied to named W229 or W230 controls and the corresponding W3 wall or Bay P station.
  • An independent corresponding-face or endpoint residual within a stated tolerance for the chosen physical front, preserving conflicts and W3 trace uncertainty separately.
  • Remaining fractional dimensions and endpoint classes
  • Host wall, opening, landing and component profiles
  • Companion sheet registration and revision reconciliation
  • Independent placement/model checking
  • Complete fine dimension/profile chains, fasteners, connection details, material and finish extents remain partial.
  • Installed instances, floor applicability, governing revisions, closed landings/shaft boundaries, headroom, accepted registration and independent physical checks remain unresolved.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. The gold outline locates the selected reading. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

1 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

f1-elevator-2verified · derived

detail_u_axis_world_vector

+u = +X west/Broadway

Exact symbolic vector [1,0] retained in display metadata; the scalar value remains null.

View all source photographs →