Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1250 · Folder 189

DETAIL OF UPPER STORIES — BROADWAY ELEVATION

Sheet W207

Extraction: Reviewed · extraction partial. Identify and audit the next exact companion detail for the registered Broadway elevation and sectional stone-face controls, preserving printed dimensions and boundary semantics without propagating one photographed detail to every Broadway bay. W207 upper-opening elevation, Sections A-A/B-B/C-C: local dimensions, sash layout and physical authorability reviewed. Partial timed visual review: Printed specification or source-local detail only; no installed quantity, accepted room geometry, host placement or building transform established.

Highlighted reading: 1.645833333 ft.

Show every recorded property on this drawing →

Unresolved extraction work
  • Reviewed W207 cut-line/type-mark correspondence to a unique IMG_1231 Broadway bay and opening ID
  • Overall exterior stone face to interior finish face wall thickness
  • Classification and world X of the W207 interior finish face
  • Exact stone, backing, cavity and plaster layer thickness chain
  • Whether the 10 1/2-inch and 1-foot returns are jamb-specific, plane-family-specific or another local condition
  • Accepted rough-opening versus masonry-opening versus steel-sash/frame boundaries on IMG_1231
  • Lower-story wall and first-floor jamb geometry from IMG_1246/IMG_1247
  • Upper-story head/library special-condition relationship of IMG_1300 to W207
  • Independent as-built or companion-plan check
  • The steel sash lacks all finite frame/mullion/glass sections and fabrication offsets; the marble stool lacks a closed profile; the tile has thickness only, with no bounded patch; the opening lacks a classified rough width and host depth. The 4/11 building bay, wall X and checked plan/elevation station are also unresolved.
  • Remaining small dimension fractions, profile boundaries, fasteners and dense notes require targeted master/clearer companion review
  • Installed instances, quantities, room registration and revisions remain unresolved
  • All-region measured extraction and architectural acceptance remain incomplete

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. The gold outline locates the selected reading. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

1 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

bway-W207-upper-story-detail-assemblyverified · derived

masonry-opening-head-to-next-finished-floor

1.645833333 ft

1.645833 ft

Arithmetic remainder only; the small photographed head-zone label is not quoted as a separately verified printed value. Source audit state: verified-arithmetic.

IMG_1250 · sheet-W207 · Locate on drawing ↗

Drawing notation: 11'-6"; 2'-1 1/2"; 7'-8 3/4"

Calculated from: bway-W207-F3-F4-floor-to-floor, bway-W207-floor-to-masonry-opening-bottom, bway-W207-masonry-opening-height

View all source photographs →