Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
stair-w228-typical-detail-registerverified · printed
material_code_marble
MARBLEPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: MARBLE
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-typical-detail-registerverified · printed
material_code_concrete
CONCRETEPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: CONCRETE
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-typical-detail-registerverified · printed
material_code_terra_cotta
TERRA COTTAPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: TERRA COTTA
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-typical-detail-registerverified · printed
material_code_plaster
PLASTERPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: PLASTER
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-typical-detail-registerverified · printed
material_code_wood
WOODPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: WOOD
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-typical-detail-registerverified · printed
material_code_metal
METALPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: METAL
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-typical-detail-registerverified · printed
material_code_cement_finish
CEMENT FINISHPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: CEMENT FINISH
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-typical-detail-registerverified · printed
material_code_terrazzo
TERRAZZOPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: TERRAZZO
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-typical-detail-registerverified · printed
material_code_tile
TILEPrinted source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: TILE
Printed source material-code legend entry only. Pattern-to-component assignments require matching each actual drawn hatch/leader and governing section; no installation material or quantity inferred.
stair-w228-bde-rail-profile-registerverified · printed
newel_cap_lower_stepped_segment_vertical_source_witness
2″2 in
Short printed vertical witness adjacent lower stepped cap/newel region; extension stations establish a2in local span. It is neither overall cap-tip height nor installed rail height; fabrication-piece boundaries remain open.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: 2″
Short printed vertical witness adjacent lower stepped cap/newel region; extension stations establish a2in local span. It is neither overall cap-tip height nor installed rail height; fabrication-piece boundaries remain open.
Calculated from: stairprofile1013o-img_1122-m001, stairbuild1013f-img_1122-m017
stair-w228-bde-rail-profile-registerverified · printed
lower_isolated_string_profile_inner_moulding_source_span
1½″1.5 in
Lower isolated string profile:1½in inner left moulding control between separate extension stations alongside10in middle face. No overall string depth, gauge, tread nosing, upper-profile equality or installation transfer.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: 1½″
Lower isolated string profile:1½in inner left moulding control between separate extension stations alongside10in middle face. No overall string depth, gauge, tread nosing, upper-profile equality or installation transfer.
Calculated from: stairbuild1013f-img_1265-m027, stairbuild1013f-img_1265-m028
stair-w228-bde-rail-profile-registerillegible · printed
upper_isolated_string_profile_left_offset_fraction_unresolved
1[small fraction not certified]″Numeric value unresolved
Upper isolated string profile left small offset fraction remains uncertified. Lower isolated profile1½in is a different witness and cannot resolve this token.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: 1[small fraction not certified]″
Upper isolated string profile left small offset fraction remains uncertified. Lower isolated profile1½in is a different witness and cannot resolve this token.
Calculated from: stairbuild1013f-img_1265-m028
stair-w228-bde-rail-profile-registerillegible · printed
upper_isolated_string_profile_right_trim_fraction_unresolved
[small right fraction]″Numeric value unresolved
Upper profile narrow right return fraction beside10in middle face remains illegible; no metal gauge or rail tubing wall dimension inferred.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: [small right fraction]″
Upper profile narrow right return fraction beside10in middle face remains illegible; no metal gauge or rail tubing wall dimension inferred.
Calculated from: stairbuild1013f-img_1265-m028
stair-w228-bde-rail-profile-registerillegible · printed
lower_isolated_string_profile_outer_left_fraction_unresolved
[small outer-left fraction]″Numeric value unresolved
Lower isolated profile outer-left narrow segment before1½in moulding control remains separate and unreadable. No overall profile sum.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: [small outer-left fraction]″
Lower isolated profile outer-left narrow segment before1½in moulding control remains separate and unreadable. No overall profile sum.
Calculated from: stairbuild1013f-img_1265-m028
stair-w228-bde-rail-profile-registerillegible · printed
lower_isolated_string_profile_right_trim_fraction_unresolved
[small right fraction]″Numeric value unresolved
Lower profile narrow right return fraction not certified. Do not select a gauge or borrow a neighboring profile fraction.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: [small right fraction]″
Lower profile narrow right return fraction not certified. Do not select a gauge or borrow a neighboring profile fraction.
Calculated from: stairbuild1013f-img_1265-m028
stair-w228-bde-rail-profile-registerverified · observed
single_tread_support_depicted_circular_joint_positions
[two open circular joint symbols beneath selected horizontal tread support]2 count
Two circular symbols beneath one selected horizontal tread support are depicted type joint positions only. Symbols do not establish bolt/screw type, diameter, pitch, material, substrate, anchorage or installed count.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: [two open circular joint symbols beneath selected horizontal tread support]
Two circular symbols beneath one selected horizontal tread support are depicted type joint positions only. Symbols do not establish bolt/screw type, diameter, pitch, material, substrate, anchorage or installed count.
stair-w228-bde-rail-profile-registerverified · observed
single_riser_support_depicted_circular_joint_positions
[two open circular joint symbols on selected vertical riser support]2 count
Two circular symbols on selected vertical support above landing are depicted type positions only. No size, metal gauge, fastener type or installation quantity established.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: [two open circular joint symbols on selected vertical riser support]
Two circular symbols on selected vertical support above landing are depicted type positions only. No size, metal gauge, fastener type or installation quantity established.
stair-w228-bde-rail-profile-registerverified · printed
newel_square_nominal_side
4″ SQ NEWEL4 in
Same lower B/D/E newel square leader as prior non-null candidate, original white drawing layer. Nominal square source section only; tubing wall, cast cap, installed quantities and neighboring handrail dimensions separate.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: 4″ SQ NEWEL
Same lower B/D/E newel square leader as prior non-null candidate, original white drawing layer. Nominal square source section only; tubing wall, cast cap, installed quantities and neighboring handrail dimensions separate.
stair-w228-bde-rail-profile-registerverified · printed
upper_isolated_string_profile_left_offset_resolution
1¼″1.25 in
Original white drawing layer, upper isolated string profile immediately below the inclined B/D/E panel. Correct125-degree clockwise crop shows left segment before10in body as1¼in. Separate from lower isolated profile1½in and narrow outer/trim segments. Whole crop rectangle is provenance, not trace or complete profile acceptance.
IMG_1122 · W-228 · Locate on drawing ↗Drawing notation: 1¼″
Original white drawing layer, upper isolated string profile immediately below the inclined B/D/E panel. Correct125-degree clockwise crop shows left segment before10in body as1¼in. Separate from lower isolated profile1½in and narrow outer/trim segments. Whole crop rectangle is provenance, not trace or complete profile acceptance.