Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1097 · Folder 191

First-floor elevator door elevation close-up

Sheet W217

Extraction: Reviewed · extraction partial. Bounded first-floor elevator audit: First-floor elevator door elevation close-up. Bounded W217 confirmation: Printed entrance dimensions and their extension-line endpoints. This photograph is a crop and contains no title block. Bounded source-first extraction of printed jamb widths, door-panel controls, position-indicator identity, model-number tags and named materials in the W217 entrance elevation, beyond the previously accepted 3'-6" by 6'-9 3/4" finished entrance envelope. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays. Normalized from an existing text re-audit; this import did not reopen the source image. Elevator-front bounded gate: Finished entrance and ornamental jamb face-width chains, panel offsets and material labels. Elevator No. 1 first-floor cross-sheet physical placement gate; one-axis controls only. Elevator No. 1 first-floor cross-sheet physical placement gate; one-axis controls only. Partial timed visual review: Source-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established. Partial timed visual review: undefined

Highlighted reading: metal elevator doors with cast ornament.

Show every recorded property on this drawing →

Unresolved extraction work
  • Accepted world wall faces and exact shaft polygons for all three elevators
  • Registered relationship between W229/W230/W231 detail coordinates and W3 world coordinates
  • Rough-versus-finished enclosure wall planes and wall thicknesses
  • W217 title-block confirmation and exact endpoint interpretation for the 3'-6" and 6'-9 3/4" door readings
  • Exact first-floor Elevator 3 door width, height, jamb/head/sill and rough opening
  • Readable Elevator 3 vertical hatch/shaft witness
  • Car/cab/platform sizes, rail/counterweight coordinates, pit depths and overhead clearances
  • Accepted ramp length, slope and threshold build-up at Elevator 3
  • Architecturally accepted reconciliation of all floor traces, especially the fourth-floor mechanical underlay
  • Operating clear width and height after door travel
  • Rough opening width and height
  • Sill, threshold and head sections/build-up
  • Individual leaf widths, thicknesses, overlap and travel
  • Outer ornamental-surround dimensions
  • Wall-face assignment and wall thickness
  • Registered world position and orientation
  • w217-entrance-missing-leaf-mechanics: The elevation shows two graphic door-face fields and a centerline but no equipment-side mechanics or travel diagram.
  • w217-entrance-missing-jamb-depth: The 6-inch values are elevation face widths only; Section E is not present in the reviewed close-up as readable construction geometry.
  • w217-entrance-missing-head-depth: No readable section dimensions establish depth.
  • w217-entrance-missing-ornament-geometry: The elevation and material callouts establish visible ornament and generic cast construction, not exact three-dimensional ornament.
  • w217-entrance-missing-panel-sizes: Only selected offsets are printed. Panel sizes may not be derived from pixels or by subtracting visually symmetric gaps from the finished envelope.
  • w217-entrance-missing-indicator-geometry: Only the printed identity and B/1-7 legend are secure.
  • w217-entrance-missing-model-32-scope: The number is clear but no unambiguous leader fixes its scope.
  • w217-entrance-missing-model-tag-propagation: Visual pattern matching alone does not establish printed model-number applicability.
  • w217-entrance-missing-plinth-geometry: MARBLE PLINTH is legible, but no securely assigned plinth dimension is printed in the reviewed region.
  • w217-entrance-missing-rough-opening: The accepted 3'-6" by 6'-9 3/4" envelope is bounded by finished entrance faces, not rough construction.
  • w217-entrance-missing-placement: No side-chain token was promoted to placement, and no detail-to-plan registration was performed in this package.
  • w217-entrance-unassigned-left-side-chain: These segments extend left of the ornamental jamb into adjacent Bay P work; their complete endpoints and component assignments are outside the close-up. They are not entrance placement controls.
  • w217-entrance-unassigned-right-side-chain: These segments run from the right ornamental jamb into adjacent vertical profile work. The close-up does not securely assign them to entrance components or placement datums.
  • w217-entrance-unassigned-right-witness: The token is legible, but its extension line and endpoints do not securely identify an entrance component or axis. It is retained as a witness, not a physical property.
  • Complete drawing-note transcription
  • Every dimension and bay placement
  • Detailed hardware/fastener schedule
  • Exact cross-sheet bay correspondence
  • Cross-photo physical deduplication
  • Complete surviving-object inventory
  • Exact dimensions
  • Construction/alteration chronology
  • Condition assessment
  • P-6 component extraction
  • Installed fixture schedule and positions
  • As-built correspondence
  • Fixture finish and glass color
  • A readable first-floor W217 Section E or applicable companion section with front and back faces and exact profile/depth dimensions for one named component, plus complete width and height endpoints for that same component.
  • Printed or independently checked panel extents before any ornament panels are given physical sizes; retain panel instances without fabricated dimensions until then.
  • Classified first-floor host wall face, thickness and jamb/reveal/sill/head interfaces tied to named W229 or W230 controls and the corresponding W3 wall or Bay P station.
  • An independent corresponding-face or endpoint residual within a stated tolerance for the chosen physical front, preserving conflicts and W3 trace uncertainty separately.
  • Fine fractions and complete witness endpoints require targeted high-resolution crops
  • Companion captures, material code and revision authority require reconciliation
  • Installed floor/room registration, exact depths and modeling checks outstanding
  • Complete adjoining chain, outer endpoints, component classification and physical registration remain unassigned; fine far-right fractions are still ambiguous.
  • Installed instance mapping, world placement, companion/revision authority and whole-building acceptance remain unresolved.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. The gold outline locates the selected reading. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

1 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

f1-elevator-doors-1-2-w217-detailverified · printed

door_material_description

metal elevator doors with cast ornament

Metal is generic; the sheet does not name an alloy, gauge, finish, backing construction or leaf thickness.

IMG_1097 · sheet-W217 · Locate on drawing ↗

Drawing notation: METAL ELEVATOR DOORS; CAST ORNAMENT.

View all source photographs →