An identified object is not a fully modeled object. Missing dimensions, locations and relationships remain explicit.
assembly · parallel-img1084-skylightModeling: not-modeled
Skylights and division bars
Research representation: none. Architectural checks: pending.
Floor assignment pending
12 recorded properties
Still to extract or check- close review of remaining dimension chains, fractions, specifications and notes
- revision history, material-code schedule and companion-sheet reconciliation
- instance quantities and building placement/room/floor registration
Inspect this object’s readings →View source IMG_1084 ↗
assembly · parallel-img1084-drainModeling: not-modeled
Roof drain
Research representation: none. Architectural checks: pending.
Floor assignment pending
1 recorded properties
Still to extract or check- close review of remaining dimension chains, fractions, specifications and notes
- revision history, material-code schedule and companion-sheet reconciliation
- instance quantities and building placement/room/floor registration
Inspect this object’s readings →View source IMG_1084 ↗
assembly · parallel-img1084-ventModeling: not-modeled
Roof vents
Research representation: none. Architectural checks: pending.
Floor assignment pending
1 recorded properties
Still to extract or check- close review of remaining dimension chains, fractions, specifications and notes
- revision history, material-code schedule and companion-sheet reconciliation
- instance quantities and building placement/room/floor registration
Inspect this object’s readings →View source IMG_1084 ↗
assembly · parallel-img1084-corniceModeling: not-modeled
Penthouse copper cornice
Research representation: none. Architectural checks: pending.
Floor assignment pending
1 recorded properties
Still to extract or check- close review of remaining dimension chains, fractions, specifications and notes
- revision history, material-code schedule and companion-sheet reconciliation
- instance quantities and building placement/room/floor registration
Inspect this object’s readings →View source IMG_1084 ↗
assembly · parallel-img1084-outletModeling: not-modeled
Roof outlets
Research representation: none. Architectural checks: pending.
Floor assignment pending
1 recorded properties
Still to extract or check- close review of remaining dimension chains, fractions, specifications and notes
- revision history, material-code schedule and companion-sheet reconciliation
- instance quantities and building placement/room/floor registration
Inspect this object’s readings →View source IMG_1084 ↗
assembly · metal1012h-img1084-jointModeling: not-modeled
Three-way armored-wire-glass expansion-joint detail
Research representation: none. Architectural checks: pending.
Floor assignment pending · Original mark: CONSTRUCTION NO.14
10 recorded properties
Still to extract or check- Glass shield section thickness and full dimensions
- Strip width and solder-joint witness endpoints
- Gauge/weight standard and installed layout/revision authority
Inspect this object’s readings →View source IMG_1084 ↗
assembly · metalenv1014t-img1084-ee-sectionModeling: not-modeled
Rooflight section E-E
Research representation: none. Architectural checks: pending.
Floor assignment pending
4 recorded properties
Still to extract or check- Remaining rooflight-plan grids, sections, levels, member profiles and full dimensions remain open.
- Remaining regional dimensions, notes, schedules, companion details and original/revision authority require review.
- Installed instances, quantities, floor/room registration and continuous physical geometry remain unestablished; no architectural acceptance.
Inspect this object’s readings →View source IMG_1084 ↗