Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1077-truckverified · printed
plan_finished_grade_label_right_bumper
EL. 90.5090.5 unknown
Leader at right bumper return. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: EL. 90.50
Leader at right bumper return. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
parallel-img1077-truckverified · printed
plan_finished_grade_label_front_right_middle
EL. 90.3690.36 unknown
Middle of three leaders on right ramp front line. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: EL. 90.36
Middle of three leaders on right ramp front line. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
parallel-img1077-truckverified · printed
plan_finished_grade_label_front_right_outer
EL. 90.4290.42 unknown
Outer of three leaders on right ramp front line. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: EL. 90.42
Outer of three leaders on right ramp front line. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
parallel-img1077-truckverified · printed
plan_finished_grade_label_right_gutter
GUTTER EL. 89.7089.7 unknown
GUTTER label and outer right ramp leader. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: GUTTER EL. 89.70
GUTTER label and outer right ramp leader. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
parallel-img1077-truckverified · printed
plan_finished_grade_label_front_left_middle
EL. 92.1592.15 unknown
Middle left-ramp front-line leader. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: EL. 92.15
Middle left-ramp front-line leader. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
parallel-img1077-truckverified · printed
plan_finished_grade_label_left_gutter
GUTTER EL. 91.9491.94 unknown
GUTTER label at left ramp curb line. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: GUTTER EL. 91.94
GUTTER label at left ramp curb line. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
parallel-img1077-truckverified · printed
plan_finished_grade_label_center_gutter
GUTTER EL. 90.7690.76 unknown
GUTTER label at central front line. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: GUTTER EL. 90.76
GUTTER label at central front line. Source-local numeric glyph; no unit, benchmark, conversion, accepted datum, installation or geometry inferred.
parallel-img1077-truckverified · printed
plan_transverse_expansion_joint_width
½″ EXPANSION JOINT0.5 in
Transverse joint between bumper returns; no installed joint length or location established. Source-local only; endpoint boundary class, installed applicability and geometry remain unaccepted.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: ½″ EXPANSION JOINT
Transverse joint between bumper returns; no installed joint length or location established. Source-local only; endpoint boundary class, installed applicability and geometry remain unaccepted.
parallel-img1077-truckverified · printed
plan_left_half_front_transverse_span
17′-9″213 in
Left half of the transverse front witness chain; independent of doorway rough/clear width. Source-local only; endpoint boundary class, installed applicability and geometry remain unaccepted.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: 17′-9″
Left half of the transverse front witness chain; independent of doorway rough/clear width. Source-local only; endpoint boundary class, installed applicability and geometry remain unaccepted.
parallel-img1077-platformverified · printed
platform-door-plan-selected-horizontal-span
3′-2″38 in
Printed selected plan segment ends on centre witness; not a total opening width. Source-local detail/type only; no installed quantity or physical placement.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: 3′-2″
Printed selected plan segment ends on centre witness; not a total opening width. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1077-platformverified · printed
platform-transom-grilles-companion-sheet
SEE SHEET #220 FOR DETAIL OF TRANSOM & GRILLES220 sheet-number
Source-local detail/type only; no installed quantity or physical placement.
parallel-img1077-truckverified · printed
section-nn-floor-metal-tile-thickness
⅛″ THICK METAL TILES0.125 in
Printed N-N floor covering is tiles; separate from prior unresolved plate note. Source-local detail/type only; no installed quantity or physical placement.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: ⅛″ THICK METAL TILES
Printed N-N floor covering is tiles; separate from prior unresolved plate note. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1077-truckverified · printed
section-nn-floor-covering-material
METAL TILES Source-local detail/type only; no installed quantity or physical placement.
parallel-img1077-truckunreviewed · printed
section-nn-floor-tile-joint-method
[BUTT…] JOINTS [joint adjective unresolved]Unusual printed spelling retained; interpretation butt joints not silently substituted. Source-local detail/type only; no installed quantity or physical placement.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: [BUTT…] JOINTS [joint adjective unresolved]
Unusual printed spelling retained; interpretation butt joints not silently substituted. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1077-truckverified · printed
section-nn-floor-tile-fixing
COUNTERSUNK SCREWS Source-local detail/type only; no installed quantity or physical placement.
parallel-img1077-truckverified · printed
section-mm-wainscot-metal-thickness
⅛″ THICK METAL WAINSCOT0.125 in
Separate wall covering from floor tile. Source-local detail/type only; no installed quantity or physical placement.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: ⅛″ THICK METAL WAINSCOT
Separate wall covering from floor tile. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1077-truckverified · printed
section-mm-ceiling-furring-material
METAL FURRING & LATHDistinct supporting construction beneath already recorded cement-plaster ceiling. Source-local detail/type only; no installed quantity or physical placement.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: METAL FURRING & LATH
Distinct supporting construction beneath already recorded cement-plaster ceiling. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1077-truckillegible · printed
wainscot-anchor-size-unresolved
[fractional anchor and angle notation not fully resolved]Numeric value unresolved
High-resolution crop still leaves tiny sizes/witnesses ambiguous. Source-local detail/type only; no installed quantity or physical placement.
IMG_1077 · W-206 · Locate on drawing ↗Drawing notation: [fractional anchor and angle notation not fully resolved]
High-resolution crop still leaves tiny sizes/witnesses ambiguous. Source-local detail/type only; no installed quantity or physical placement.