Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
upper-envelope-curtain-madisonunreviewed · derived
Analytical ruled-envelope strip count
11 zero-thickness strips; preview only11 count
Vertically project all five registered W3 south/loading-indentation segments only to the second-floor datum, then connect matching south cardinal edges of independently registered upper-floor traces. No vertical wall face, thickness, opening cut or physical construction is implied.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: FIRST FLOOR PLAN
Existing W3 enclosed-floor outer trace reused; not reopened for this derivation. The Madison loading indentation is retained as five separate curtain segments.
IMG_1335 · Locate on drawing ↗Drawing notation: FOURTH FLOOR PLAN / HEATING AND LIGHTING
Existing provisional MEP-underlay outer trace; not reopened and not treated as an accepted architectural wall face.
Calculated from: f1-enclosed-floor-outline-footprint-trace, f2-floor-outline-footprint-trace, f3-floor-outline-footprint-trace, f4-floor-outline-footprint-trace, f5-floor-outline-footprint-trace, f6-enclosed-floor-outline-footprint-trace, f7-enclosed-floor-outline-footprint-trace, f8-enclosed-envelope-footprint-trace, frame-first-floor-finish, frame-second-floor-finish, env-sixth-F3-level, env-sixth-F4-level, env-sixth-F5-level, frame-sixth-floor-finish, env-sixth-F7-level, frame-eighth-floor-schedule-finish
upper-envelope-curtain-sixthunreviewed · derived
Analytical ruled-envelope strip count
7 zero-thickness strips; preview only7 count
Vertically project the registered W3 east segment only to the second-floor datum, then connect matching east cardinal edges of independently registered upper-floor traces. No vertical wall face, thickness, opening cut or physical construction is implied.
IMG_1202 · W3 · Locate on drawing ↗Drawing notation: FIRST FLOOR PLAN
Existing W3 enclosed-floor outer trace reused; not reopened for this derivation. The Madison loading indentation is retained as five separate curtain segments.
IMG_1335 · Locate on drawing ↗Drawing notation: FOURTH FLOOR PLAN / HEATING AND LIGHTING
Existing provisional MEP-underlay outer trace; not reopened and not treated as an accepted architectural wall face.
Calculated from: f1-enclosed-floor-outline-footprint-trace, f2-floor-outline-footprint-trace, f3-floor-outline-footprint-trace, f4-floor-outline-footprint-trace, f5-floor-outline-footprint-trace, f6-enclosed-floor-outline-footprint-trace, f7-enclosed-floor-outline-footprint-trace, f8-enclosed-envelope-footprint-trace, frame-first-floor-finish, frame-second-floor-finish, env-sixth-F3-level, env-sixth-F4-level, env-sixth-F5-level, frame-sixth-floor-finish, env-sixth-F7-level, frame-eighth-floor-schedule-finish
detail-floor4-radiator-rule-1335verified · printed
radiator-tube-count
ALL RADIATORS ON THIS FLOOR TO BE 3 TUBE3 count
Printed fourth-floor default; conditional height preserved. Does not establish per-room radiator geometry or installed quantity. Access image requires 180° clockwise correction.
IMG_1335 · Locate on drawing ↗Drawing notation: ALL RADIATORS ON THIS FLOOR TO BE 3 TUBE
Printed fourth-floor default; conditional height preserved. Does not establish per-room radiator geometry or installed quantity. Access image requires 180° clockwise correction.
detail-floor4-radiator-rule-1335verified · printed
radiator-height-unless-noted
20″ HIGH UNLESS OTHERWISE NOTED20 in
Printed fourth-floor default; conditional height preserved. Does not establish per-room radiator geometry or installed quantity. Access image requires 180° clockwise correction.
IMG_1335 · Locate on drawing ↗Drawing notation: 20″ HIGH UNLESS OTHERWISE NOTED
Printed fourth-floor default; conditional height preserved. Does not establish per-room radiator geometry or installed quantity. Access image requires 180° clockwise correction.
detail-floor4-radiator-rule-1335verified · printed
radiator-connection-relationship
ALL RADIATOR CONNECTIONS SHALL BE BROUGHT THRU WALLPrinted fourth-floor default; conditional height preserved. Does not establish per-room radiator geometry or installed quantity. Access image requires 180° clockwise correction.
IMG_1335 · Locate on drawing ↗Drawing notation: ALL RADIATOR CONNECTIONS SHALL BE BROUGHT THRU WALL
Printed fourth-floor default; conditional height preserved. Does not establish per-room radiator geometry or installed quantity. Access image requires 180° clockwise correction.
detail-floor4-electrical-junction-reference-1335verified · printed
system-caption
ELECTRICAL SYSTEMPrinted approximate elevation retained as provisional feet because elevation unit is not stated locally; center-of-travel relationship does not locate a physical installed box. Floor and vertical datum registration missing.
IMG_1335 · Locate on drawing ↗Drawing notation: ELECTRICAL SYSTEM
Printed approximate elevation retained as provisional feet because elevation unit is not stated locally; center-of-travel relationship does not locate a physical installed box. Floor and vertical datum registration missing.
detail-floor4-electrical-junction-reference-1335verified · printed
junction-box-purpose
Junction Boxes for Elevator Lights to be Placed at Center of Travel.Printed approximate elevation retained as provisional feet because elevation unit is not stated locally; center-of-travel relationship does not locate a physical installed box. Floor and vertical datum registration missing.
IMG_1335 · Locate on drawing ↗Drawing notation: Junction Boxes for Elevator Lights to be Placed at Center of Travel.
Printed approximate elevation retained as provisional feet because elevation unit is not stated locally; center-of-travel relationship does not locate a physical installed box. Floor and vertical datum registration missing.
detail-floor4-electrical-junction-reference-1335provisional · printed
approximate-elevation
Approx El 129.00129 ft
Printed approximate elevation retained as provisional feet because elevation unit is not stated locally; center-of-travel relationship does not locate a physical installed box. Floor and vertical datum registration missing.
IMG_1335 · Locate on drawing ↗Drawing notation: Approx El 129.00
Printed approximate elevation retained as provisional feet because elevation unit is not stated locally; center-of-travel relationship does not locate a physical installed box. Floor and vertical datum registration missing.
lighting1013d-img1335-room405-two-stations-station-01verified · observed
drawn_outlet_station_presence
One plain circular electrical outlet symbol1 count
Source-local drawn evidence only; not accepted installed geometry, quantity, lamp wattage or P-type mapping.
IMG_1335 · Locate on drawing ↗Drawing notation: One plain circular electrical outlet symbol
Source-local drawn evidence only; not accepted installed geometry, quantity, lamp wattage or P-type mapping.
lighting1013d-img1335-room405-two-stations-station-01verified · printed
printed_station_number
300300 number
Printed number beside station; no local W suffix or governing P-type correlation certified. Number is neither historical instance ID nor installed quantity.
IMG_1335 · Locate on drawing ↗Drawing notation: 300
Printed number beside station; no local W suffix or governing P-type correlation certified. Number is neither historical instance ID nor installed quantity.
lighting1013d-img1335-room405-two-stations-station-01unreviewed · observed
luminaire_type_mapping
UnresolvedNo governing fixture/P-type key verified in this bounded station crop; not evidence that no key survives elsewhere.
lighting1013d-img1335-room405-two-stations-station-02verified · observed
drawn_outlet_station_presence
One plain circular electrical outlet symbol1 count
Source-local drawn evidence only; not accepted installed geometry, quantity, lamp wattage or P-type mapping.
IMG_1335 · Locate on drawing ↗Drawing notation: One plain circular electrical outlet symbol
Source-local drawn evidence only; not accepted installed geometry, quantity, lamp wattage or P-type mapping.
lighting1013d-img1335-room405-two-stations-station-02verified · printed
printed_station_number
300300 number
Printed number beside station; no local W suffix or governing P-type correlation certified. Number is neither historical instance ID nor installed quantity.
IMG_1335 · Locate on drawing ↗Drawing notation: 300
Printed number beside station; no local W suffix or governing P-type correlation certified. Number is neither historical instance ID nor installed quantity.
lighting1013d-img1335-room405-two-stations-station-02unreviewed · observed
luminaire_type_mapping
UnresolvedNo governing fixture/P-type key verified in this bounded station crop; not evidence that no key survives elsewhere.
lighting1013d-img1335-room405-two-stationsverified · derived
drawn_regional_station_count
2 individually recorded plain circular outlet stations2 count
Sum of the separately recorded drawn stations in this bounded group only. Excludes adjacent symbol families, routes and unreviewed stations; does not establish installed count.
IMG_1335 · Locate on drawing ↗Drawing notation: 2 individually recorded plain circular outlet stations
Sum of the separately recorded drawn stations in this bounded group only. Excludes adjacent symbol families, routes and unreviewed stations; does not establish installed count.
Calculated from: lighting1013d-img1335-050-drawn_outlet_station_presence, lighting1013d-img1335-053-drawn_outlet_station_presence
lighting1013d-img1335-room405-two-stationsverified · printed
printed_room_number_witness
405405 identifier
Printed room witness inside the outlined source-local bay containing these stations; architectural-room registration and historical installation remain unaccepted.
IMG_1335 · Locate on drawing ↗Drawing notation: 405
Printed room witness inside the outlined source-local bay containing these stations; architectural-room registration and historical installation remain unaccepted.
f4-room-429verified · printed
printed_room_number
429429 identifier
Fourth-floor printed room label, not dimensions or installation.
f4-room-430verified · printed
printed_room_number
430430 identifier
Fourth-floor printed room label, not dimensions or installation.
f4-room-431verified · printed
printed_room_number
431431 identifier
Fourth-floor printed room label, not dimensions or installation.
f4-room-432verified · printed
printed_room_number
432432 identifier
Fourth-floor printed room label, not dimensions or installation.
f4-room-433verified · printed
printed_room_number
433433 identifier
Fourth-floor printed room label, not dimensions or installation.
f4-room-434verified · printed
printed_room_number
434434 identifier
Fourth-floor printed room label, not dimensions or installation.
f4-room-435verified · printed
printed_room_number
435435 identifier
Fourth-floor printed room label, not dimensions or installation.
f4-room-436verified · printed
printed_room_number
436436 identifier
Fourth-floor printed room label, not dimensions or installation.
f4-room-437verified · printed
printed_room_number
437437 identifier
Fourth-floor printed room label, not dimensions or installation.