Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1324 · Folder 186

Floor And Roof

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial catalogue/OCR-first then sequential <=1000px JPEG65 locator review of public/archive/drawings/complete-upright/IMG_1324.webp. IMG_1322 additionally has one 250x435 post-schedule crop. Regions normalized in unrotated access-image coordinates; rotationDegrees is clockwise correction. Selected evidence only, no full extraction/modeling. Partial timed visual review: Additive partial high-resolution access-derivative crop review following batch13-b; original printed evidence only unless explicitly marked OCR conflict. Not full image extraction. Source is 2200x1650 upright access derivative, not master; crop has no resampling or rotation. Partial timed visual review: Prior-package and OCR audit only; no new image inspection or duplicate verified readings. Partial timed visual review: Sequential access locator and two unrotated raw-master targeted crops; additive truss and girder evidence only. Tags are printed associations and do not establish accepted physical connections. Partial timed visual review: Prior evidence reused; only selected remaining source-local regions reviewed. No historical placement or accepted physical geometry. Partial timed visual review: undefined Partial timed visual review: Source-local schedule, fabrication or connection evidence only; no installed geometry or architectural acceptance. Partial timed visual review: undefined Partial timed visual review: undefined

Unresolved extraction work
  • partial locator coverage; remaining individual beam/member sizes, schedules, fine fractions and dimensions outstanding
  • all notes, revisions, symbols, utility legends and companion details require reconciliation
  • historical instance locations, material grades, connection capacities and modeling checks missing
  • Uncropped sheet regions, revisions and title-block detail not reviewed in closeout.
  • All unreadable fractions, individual connection plates/angles/rivets, material grades and instance placement remain outstanding.
  • No master-resolution comparison; access derivative limits fine-text evidence.
  • Remaining member, reinforcement and connection dimensions require fine-region review
  • Revision marks and historical instance placements remain unreconciled
  • Companion-sheet registration and modeling checks remain outstanding
  • Complete fine-fraction/member schedule transcription
  • Historical instance mapping and endpoint registration
  • Annotated revisions and companion notes reconciliation
  • Accepted connections and modeling checks
  • Complete member/plate/bar fraction transcription
  • Historical instance and source-to-plan registration
  • Revision authority and companion applicability
  • Connection and modeling acceptance checks
  • GirderB rivet fraction and flange widths/thicknesses remain unresolved; list lengths are not full girder length or world endpoints.
  • Flange plate list row2 and row3 component quantities are one each for this detail, not installed building quantities.
  • Complete source-to-instance registration, physical endpoints, installed quantities and revision authority remain unresolved.
  • Unreviewed regions, companion sheets, schedules and fine fractions remain open; this package is not exhaustive coverage.
  • Material grades, connection capacities, world transforms and independent model/as-built checks remain unestablished.
  • Complete source-to-plan registration and installed-instance applicability remain unresolved.
  • Unreviewed sheet regions, notes, callouts, schedules and revision authority remain open.
  • Material grades, full profiles, connection capacities and independent modeling checks unresolved.
  • Girder A rivet fraction resolves; Girder B fraction remains deliberately open despite candidate appearance.
  • Flange/web plate fractions, supports and load-endpoint installation mapping remain partial.
  • Complete source-to-instance and endpoint registration remains unresolved.
  • Material grades, finishes, connection capacities and as-built checks remain unestablished.
  • Unreviewed regions, fine fractions, schedules, companion applicability and revision authority remain open.
  • Girder C original rivet diameter resolves; flange widths/thicknesses, web fraction, adjacent girder details and installation remain open.
  • Full source-to-instance assignment, physical endpoints, installed quantities and governing revision remain unresolved.
  • Unreviewed regions, notes, fine fractions and companion sheets remain open; this package is not exhaustive coverage.
  • No world geometry, material grade, structural capacity or model acceptance established.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

78 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1324-trussaverified · printed

printed_mark

TRUSS A

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: TRUSS A

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-trussaunreviewed · printed

member_sizes_and_loads

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-trussbverified · printed

printed_mark

TRUSS B

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: TRUSS B

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-trussbunreviewed · printed

member_sizes_and_loads

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-trussdverified · printed

printed_mark

TRUSS D

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: TRUSS D

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-trussdunreviewed · printed

member_sizes_and_loads

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girderaverified · printed

printed_mark

GIRDER A

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: GIRDER A

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girderaunreviewed · printed

member_sizes_and_loads

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girderbverified · printed

printed_mark

GIRDER B

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: GIRDER B

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girderbunreviewed · printed

member_sizes_and_loads

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girdercverified · printed

printed_mark

GIRDER C

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: GIRDER C

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girdercunreviewed · printed

member_sizes_and_loads

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girderdverified · printed

printed_mark

GIRDER D

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: GIRDER D

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girderdunreviewed · printed

member_sizes_and_loads

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girdereverified · printed

printed_mark

GIRDER E

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: GIRDER E

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girdereunreviewed · printed

member_sizes_and_loads

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-purlinverified · printed

assignment

ROOF PURLIN CONNECTION

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: ROOF PURLIN CONNECTION

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-purlinverified · printed

ceiling_similarity

NOTE: CEILING BEAM CONNECTIONS SIMILAR

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: NOTE: CEILING BEAM CONNECTIONS SIMILAR

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-roofbraceverified · printed

assignment

ROOF TRUSS BRACING

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: ROOF TRUSS BRACING

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1324-girderaverified · printed

depicted_span_dimension

29'-0"

348 in

Original printed crop evidence; no annotation substituted. Dimension applies to depicted girder span, not building-grid measurement.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 29'-0"

Original printed crop evidence; no annotation substituted. Dimension applies to depicted girder span, not building-grid measurement.

parallel-img1324-girderaverified · printed

distributed_load

2120# PER FT.

2120 lb/ft

Original printed crop evidence; no annotation substituted.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 2120# PER FT.

Original printed crop evidence; no annotation substituted.

parallel-img1324-girderaverified · printed

unregistered_horizontal_dimension

14′-0″

168 in

Original printed crop evidence; no annotation substituted. Printed internal horizontal dimension; endpoints require detailed registration before use.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 14′-0″

Original printed crop evidence; no annotation substituted. Printed internal horizontal dimension; endpoints require detailed registration before use.

parallel-img1324-girderaunreviewed · printed

rivet_diameter

Unresolved

Numeric value unresolved

Original printed crop evidence; no annotation substituted. Rivet fraction remains ambiguous despite crop.

IMG_1324 · W-410 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. Rivet fraction remains ambiguous despite crop.

parallel-img1324-girderaunreviewed · printed

flange_plate_sizes

Unresolved

Original printed crop evidence; no annotation substituted. Plate list visible but fractions/row assignments not safely resolved.

IMG_1324 · W-410 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. Plate list visible but fractions/row assignments not safely resolved.

parallel-img1324-girderbverified · printed

depicted_span_dimension

27'-0"

324 in

Original printed crop evidence; no annotation substituted. Dimension applies to depicted girder span, not building-grid measurement.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 27'-0"

Original printed crop evidence; no annotation substituted. Dimension applies to depicted girder span, not building-grid measurement.

parallel-img1324-girderbverified · printed

distributed_load

1820# PER FT.

1820 lb/ft

Original printed crop evidence; no annotation substituted.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 1820# PER FT.

Original printed crop evidence; no annotation substituted.

parallel-img1324-girderbverified · printed

unregistered_horizontal_dimension

14′-0″

168 in

Original printed crop evidence; no annotation substituted. Printed internal horizontal dimension; endpoints require detailed registration before use.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 14′-0″

Original printed crop evidence; no annotation substituted. Printed internal horizontal dimension; endpoints require detailed registration before use.

parallel-img1324-girderbunreviewed · printed

rivet_diameter

Unresolved

Numeric value unresolved

Original printed crop evidence; no annotation substituted. Rivet fraction remains ambiguous despite crop.

IMG_1324 · W-410 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. Rivet fraction remains ambiguous despite crop.

parallel-img1324-girderbunreviewed · printed

flange_plate_sizes

Unresolved

Original printed crop evidence; no annotation substituted. Plate list visible but fractions/row assignments not safely resolved.

IMG_1324 · W-410 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. Plate list visible but fractions/row assignments not safely resolved.

parallel-img1324-girdercverified · printed

depicted_span_dimension

29'-0"

348 in

Original printed crop evidence; no annotation substituted. Dimension applies to depicted girder span, not building-grid measurement.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 29'-0"

Original printed crop evidence; no annotation substituted. Dimension applies to depicted girder span, not building-grid measurement.

parallel-img1324-girdercverified · printed

distributed_load

2120# PER FT.

2120 lb/ft

Original printed crop evidence; no annotation substituted.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 2120# PER FT.

Original printed crop evidence; no annotation substituted.

parallel-img1324-girdercverified · printed

unregistered_horizontal_dimension

14′-0″

168 in

Original printed crop evidence; no annotation substituted. Printed internal horizontal dimension; endpoints require detailed registration before use.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 14′-0″

Original printed crop evidence; no annotation substituted. Printed internal horizontal dimension; endpoints require detailed registration before use.

parallel-img1324-girdercunreviewed · printed

rivet_diameter

Unresolved

Numeric value unresolved

Original printed crop evidence; no annotation substituted. Rivet fraction remains ambiguous despite crop.

IMG_1324 · W-410 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. Rivet fraction remains ambiguous despite crop.

parallel-img1324-girdercunreviewed · printed

flange_plate_sizes

Unresolved

Original printed crop evidence; no annotation substituted. Plate list visible but fractions/row assignments not safely resolved.

IMG_1324 · W-410 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. Plate list visible but fractions/row assignments not safely resolved.

parallel-img1324-girderdverified · printed

depicted_span_dimension

29'-0"

348 in

Original printed crop evidence; no annotation substituted. Dimension applies to depicted girder span, not building-grid measurement.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 29'-0"

Original printed crop evidence; no annotation substituted. Dimension applies to depicted girder span, not building-grid measurement.

parallel-img1324-girderdverified · printed

distributed_load

1775# PER FT.

1775 lb/ft

Original printed crop evidence; no annotation substituted.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 1775# PER FT.

Original printed crop evidence; no annotation substituted.

parallel-img1324-girderdverified · printed

unregistered_horizontal_dimension

14′-0″

168 in

Original printed crop evidence; no annotation substituted. Printed internal horizontal dimension; endpoints require detailed registration before use.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: 14′-0″

Original printed crop evidence; no annotation substituted. Printed internal horizontal dimension; endpoints require detailed registration before use.

parallel-img1324-girderdunreviewed · printed

rivet_diameter

Unresolved

Numeric value unresolved

Original printed crop evidence; no annotation substituted. Rivet fraction remains ambiguous despite crop.

IMG_1324 · W-410 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. Rivet fraction remains ambiguous despite crop.

parallel-img1324-girderdunreviewed · printed

flange_plate_sizes

Unresolved

Original printed crop evidence; no annotation substituted. Plate list visible but fractions/row assignments not safely resolved.

IMG_1324 · W-410 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. Plate list visible but fractions/row assignments not safely resolved.

parallel-img1324-girderdverified · printed

fireproofing_companion_note

SEE 2ND FLOOR FRAMING PLAN FOR FIREPROOFING AROUND GIRDERS.

Original printed crop evidence; no annotation substituted.

IMG_1324 · W-410 · Locate on drawing ↗

Drawing notation: SEE 2ND FLOOR FRAMING PLAN FOR FIREPROOFING AROUND GIRDERS.

Original printed crop evidence; no annotation substituted.

View all source photographs →