Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1322 · Folder 186

Framing For Fan Room Roof

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial catalogue/OCR-first then sequential <=1000px JPEG65 locator review of public/archive/drawings/complete-upright/IMG_1322.webp. IMG_1322 additionally has one 250x435 post-schedule crop. Regions normalized in unrotated access-image coordinates; rotationDegrees is clockwise correction. Selected evidence only, no full extraction/modeling. Partial timed visual review: Prior-package and OCR audit only; no new image inspection or duplicate verified readings. Partial timed visual review: Text/OCR and prior-package audit only; no new image inspection and no duplicate verified measurements. Partial timed visual review: Prior evidence reused; only selected remaining source-local regions reviewed. No historical placement or accepted physical geometry. Partial timed visual review: undefined Partial timed visual review: Selected remaining printed structural regions only; source-local detail/schedule records establish no accepted physical geometry. Partial timed visual review: Source-local schedule, fabrication or connection evidence only; no installed geometry or architectural acceptance. Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: undefined

Unresolved extraction work
  • partial locator coverage; remaining individual beam/member sizes, schedules, fine fractions and dimensions outstanding
  • all notes, revisions, symbols, utility legends and companion details require reconciliation
  • historical instance locations, material grades, connection capacities and modeling checks missing
  • Remaining member, reinforcement and connection dimensions require fine-region review
  • Revision marks and historical instance placements remain unreconciled
  • Companion-sheet registration and modeling checks remain outstanding
  • Complete fine-fraction/member schedule transcription
  • Historical instance mapping and endpoint registration
  • Annotated revisions and companion notes reconciliation
  • Accepted connections and modeling checks
  • Complete member/plate/bar fraction transcription
  • Historical instance and source-to-plan registration
  • Revision authority and companion applicability
  • Connection and modeling acceptance checks
  • Prior verified P18/P26 half-inch thickness readings reused; bottom186.17 unit and installed post mappings remain open.
  • Handwritten slab/reinforcement revision questions remain separate; no new image view.
  • Complete source-to-instance registration, physical endpoints, installed quantities and revision authority remain unresolved.
  • Unreviewed regions, companion sheets, schedules and fine fractions remain open; this package is not exhaustive coverage.
  • Material grades, connection capacities, world transforms and independent model/as-built checks remain unestablished.
  • Complete fine-fraction/weight transcription and ditto-cell reconciliation
  • Revision authority and companion-sheet applicability
  • Connection capacity and modeling acceptance checks
  • Complete source-to-plan registration and installed-instance applicability remain unresolved.
  • Unreviewed sheet regions, notes, callouts, schedules and revision authority remain open.
  • Material grades, full profiles, connection capacities and independent modeling checks unresolved.
  • Post18/26 thickness fractions and colored slab/reinforcement revision authority remain open; failed same-resolution tokens not re-viewed.
  • Support labels94/95/96 and bay spans are local to depicted fan-room roof, not an accepted global coordinate placement.
  • Complete source-to-instance and endpoint registration remains unresolved.
  • Material grades, finishes, connection capacities and as-built checks remain unestablished.
  • Unreviewed regions, fine fractions, schedules, companion applicability and revision authority remain open.
  • Handwritten 4″ slab / ⅜″ diameter / 6″ O.C. note is legible; revision authority, exact field limits and installed applicability remain unknown.
  • Individual original printed member-size questions remain separate and unresolved.
  • Full source-to-instance assignment, physical endpoints, installed quantities and governing revision remain unresolved.
  • Unreviewed regions, notes, fine fractions and companion sheets remain open; this package is not exhaustive coverage.
  • No world geometry, material grade, structural capacity or model acceptance established.
  • parallel-img1322-m019 stays open: angle sections and plate thickness do not exhaust all individual sizes, lengths and connection geometry.
  • Upper elevator framing members remain untranscribed where fine labels and elevation offsets cannot be confidently separated.
  • All remaining sheet regions, notes, schedules, companion applicability and original/revision reconciliation remain incomplete.
  • Installed column assignment, revision authority and world registration unresolved.
  • Material grade, coatings, connection capacity and as-built/model checks unresolved.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

198 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1322-post26unreviewed · printed

scheduled_section_notation

1L5"x5"x[fraction unresolved]

Read from targeted source crop. Printed ditto notation retained; inheritance within schedule only, not inferred from member appearance.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 1L5"x5"x[fraction unresolved]

Read from targeted source crop. Printed ditto notation retained; inheritance within schedule only, not inferred from member appearance.

parallel-img1322-post26verified · printed

angle_leg_1

5"

5 in

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 5"

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1322-post26verified · printed

angle_leg_2

5"

5 in

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 5"

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1322-post26unreviewed · printed

angle_thickness

Unresolved

Numeric value unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1322 · W-408 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1322-post26verified · printed

bottom_level_notation

186.17

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 186.17

Selected visible source evidence only; partial review, applies to depicted assembly.

struct-gap-img1322-elevator1-referenceverified · printed

beam_elevation_reference_face

ELEVATIONS TO TOP OF BEAMS

Printed local annotation; registration and applicability remain unaccepted.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: ELEVATIONS TO TOP OF BEAMS

Printed local annotation; registration and applicability remain unaccepted.

struct-gap-img1322-elevator1-referenceverified · printed

beam_elevation_reference_datum

RELATIVE TO H.P. OF ROOF — ELEV. 195.42

195.42 ft

Repeated source-local roof high-point reference; does not establish beam top elevations, slab planes or correspondence to architectural roof fields.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: RELATIVE TO H.P. OF ROOF — ELEV. 195.42

Repeated source-local roof high-point reference; does not establish beam top elevations, slab planes or correspondence to architectural roof fields.

struct-gap-img1322-elevator3-referenceverified · printed

beam_elevation_reference_face

ELEVATIONS TO TOP OF BEAMS

Printed local annotation; registration and applicability remain unaccepted.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: ELEVATIONS TO TOP OF BEAMS

Printed local annotation; registration and applicability remain unaccepted.

struct-gap-img1322-elevator3-referenceverified · printed

beam_elevation_reference_datum

RELATIVE TO H.P. OF ROOF — ELEV. 195.42

195.42 ft

Repeated source-local roof high-point reference; does not establish beam top elevations, slab planes or correspondence to architectural roof fields.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: RELATIVE TO H.P. OF ROOF — ELEV. 195.42

Repeated source-local roof high-point reference; does not establish beam top elevations, slab planes or correspondence to architectural roof fields.

struct-gap-img1322-elevator2-machine-referenceverified · printed

beam_elevation_reference_face

ELEVATIONS TO TOP OF BEAMS

Printed local annotation; registration and applicability remain unaccepted.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: ELEVATIONS TO TOP OF BEAMS

Printed local annotation; registration and applicability remain unaccepted.

struct-gap-img1322-elevator2-machine-referenceverified · printed

beam_elevation_reference_datum

RELATIVE TO H.P. OF ROOF — ELEV. 195.42

195.42 ft

Repeated source-local roof high-point reference; does not establish beam top elevations, slab planes or correspondence to architectural roof fields.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: RELATIVE TO H.P. OF ROOF — ELEV. 195.42

Repeated source-local roof high-point reference; does not establish beam top elevations, slab planes or correspondence to architectural roof fields.

struct-gap-img1322-elevator2-floor-referenceverified · printed

beam_elevation_reference_face

ELEVATIONS TO TOP OF BEAMS

Printed local annotation; registration and applicability remain unaccepted.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: ELEVATIONS TO TOP OF BEAMS

Printed local annotation; registration and applicability remain unaccepted.

struct-gap-img1322-elevator2-floor-referenceverified · printed

beam_elevation_reference_datum

RELATIVE TO H.P. OF ROOF — ELEV. 195.42

195.42 ft

Printed local annotation; registration and applicability remain unaccepted.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: RELATIVE TO H.P. OF ROOF — ELEV. 195.42

Printed local annotation; registration and applicability remain unaccepted.

struct-gap-img1322-elevator2-floor-referenceverified · printed

omitted_framing_companion_reference

NOTE: FOR FRAMING OF FAN ROOM AND ELEVATOR MACHINE ROOM NOT SHOWN ON THIS DRAWING SEE DRAWINGS NOS. 406 & 407 AND ARCHITECTS DETAILS.

Printed local annotation; registration and applicability remain unaccepted.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: NOTE: FOR FRAMING OF FAN ROOM AND ELEVATOR MACHINE ROOM NOT SHOWN ON THIS DRAWING SEE DRAWINGS NOS. 406 & 407 AND ARCHITECTS DETAILS.

Printed local annotation; registration and applicability remain unaccepted.

struct-gap-img1322-elevator2-floor-revisionneeds-review · observed

annotated_slab_thickness

4″ SLAB

4 in

Observed colored handwritten annotation kept separate from original printed requirements. Historical revision authority and exact field extent unknown.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 4″ SLAB

Observed colored handwritten annotation kept separate from original printed requirements. Historical revision authority and exact field extent unknown.

struct-gap-img1322-elevator2-floor-revisionneeds-review · observed

annotated_reinforcement_spacing

[⅜?] φ 6″ O.C.

6 in

Observed handwritten spacing appears 6 inches; leading bar fraction/glyph remains a candidate and requires independent confirmation.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: [⅜?] φ 6″ O.C.

Observed handwritten spacing appears 6 inches; leading bar fraction/glyph remains a candidate and requires independent confirmation.

struct-gap-img1322-elevator2-floor-revisionneeds-review · observed

annotated_reinforcement_diameter

[⅜?] φ 6″ O.C.

Numeric value unresolved

Observed handwritten bar fraction not independently established; no numeric diameter accepted.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: [⅜?] φ 6″ O.C.

Observed handwritten bar fraction not independently established; no numeric diameter accepted.

parallel-img1322-galleryverified · printed

floor_reference_line

LINE OF FINISH 7TH FLOOR

Local upper hanger detail reference face; no world elevation derived.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: LINE OF FINISH 7TH FLOOR

Local upper hanger detail reference face; no world elevation derived.

parallel-img1322-galleryverified · printed

channel_crosswise_anchor_method

METHOD OF ANCHORING WHEN 4″ CHANNELS RUN CROSSWISE TO SUPPORTS

Applies to illustrated crosswise-channel branch only, separate from floor-beam anchoring and basement-gallery branch.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: METHOD OF ANCHORING WHEN 4″ CHANNELS RUN CROSSWISE TO SUPPORTS

Applies to illustrated crosswise-channel branch only, separate from floor-beam anchoring and basement-gallery branch.

parallel-img1322-galleryverified · printed

floor_beam_anchor_method

METHOD OF ANCHORING HANGER AT FLOOR BEAMS

Distinct upper-right anchoring branch; no installed instances inferred.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: METHOD OF ANCHORING HANGER AT FLOOR BEAMS

Distinct upper-right anchoring branch; no installed instances inferred.

parallel-img1322-galleryverified · printed

basement_anchor_method

METHOD OF ANCHORING BASEMENT FLOOR GALLERY

Distinct lower-right anchoring branch; column-axis witness belongs to basement detail.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: METHOD OF ANCHORING BASEMENT FLOOR GALLERY

Distinct lower-right anchoring branch; column-axis witness belongs to basement detail.

structsched1013g-img1322-gallery-hangerverified · printed

section_notation

2½ × ⅜″ HANGER

Explicit flat profile in gallery elevation/anchor detail; endpoints and installed length unresolved.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 2½ × ⅜″ HANGER

Explicit flat profile in gallery elevation/anchor detail; endpoints and installed length unresolved.

structsched1013g-img1322-gallery-hangerverified · printed

flat_width

2½

2.5 in

Gallery hanger profile width, drawing-local section notation.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 2½

Gallery hanger profile width, drawing-local section notation.

structsched1013g-img1322-gallery-hangerverified · printed

flat_thickness

⅜″

0.375 in

Gallery hanger profile thickness, not plate thickness of other parts.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: ⅜″

Gallery hanger profile thickness, not plate thickness of other parts.

structsched1013g-img1322-gallery-anchor-flatverified · printed

flat_width

3″ × ¼″ FLAT

3 in

Upper-right floor-beam anchor transverse flat width.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 3″ × ¼″ FLAT

Upper-right floor-beam anchor transverse flat width.

structsched1013g-img1322-gallery-anchor-flatverified · printed

flat_thickness

3″ × ¼″ FLAT

0.25 in

Upper-right floor-beam anchor transverse flat thickness.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 3″ × ¼″ FLAT

Upper-right floor-beam anchor transverse flat thickness.

parallel-img1322-galleryverified · printed

crosswise_anchor_rivet_diameter

¾″ RIVET

0.75 in

Rivet in crosswise-channel anchoring detail only.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: ¾″ RIVET

Rivet in crosswise-channel anchoring detail only.

parallel-img1322-galleryverified · printed

transverse_witness

5¼″

5.25 in

Local horizontal witness across illustrated hanger/angle projection; not gallery clear width.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 5¼″

Local horizontal witness across illustrated hanger/angle projection; not gallery clear width.

parallel-img1322-galleryverified · printed

basement_anchor_lower_vertical_witness

1′-0″

12 in

Basement anchoring lower vertical witness from upper stepped horizontal edge to bent-angle lower line.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 1′-0″

Basement anchoring lower vertical witness from upper stepped horizontal edge to bent-angle lower line.

parallel-img1322-post8verified · printed

scheduled_section_notation_resolution

6″ H @25

W408 penthouse-post row P8, explicit 6″ H @25 cell. Same row as earlier source record; no revision line/color intervention.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 6″ H @25

W408 penthouse-post row P8, explicit 6″ H @25 cell. Same row as earlier source record; no revision line/color intervention.

parallel-img1322-post8verified · printed

section_depth_resolution

6″ H @25

6 in

W408 penthouse-post row P8, explicit 6″ H @25 cell. Same row as earlier source record; no revision line/color intervention. Inch mark explicitly printed at governing P8 cell.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: 6″ H @25

W408 penthouse-post row P8, explicit 6″ H @25 cell. Same row as earlier source record; no revision line/color intervention. Inch mark explicitly printed at governing P8 cell.

Calculated from: structsched1013g-img1322-013-scheduled_section_notation_resolution

parallel-img1322-post8unreviewed · inferred

section_linear_weight_candidate

@25

25 lb/ft

W408 penthouse-post row P8, explicit 6″ H @25 cell. Same row as earlier source record; no revision line/color intervention. lb/ft is conventional @-weight interpretation; no governing weight unit found in this crop.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: @25

W408 penthouse-post row P8, explicit 6″ H @25 cell. Same row as earlier source record; no revision line/color intervention. lb/ft is conventional @-weight interpretation; no governing weight unit found in this crop.

Calculated from: structsched1013g-img1322-013-scheduled_section_notation_resolution

parallel-img1322-post9verified · printed

scheduled_section_notation_resolution

do

W408 penthouse-post row P9, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: do

W408 penthouse-post row P9, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention.

Calculated from: structsched1013g-img1322-013-scheduled_section_notation_resolution

parallel-img1322-post9verified · printed

section_depth_resolution

do

6 in

W408 penthouse-post row P9, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. Inch mark explicitly printed at governing P8 cell.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: do

W408 penthouse-post row P9, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. Inch mark explicitly printed at governing P8 cell.

Calculated from: structsched1013g-img1322-016-scheduled_section_notation_resolution, structsched1013g-img1322-013-scheduled_section_notation_resolution, structsched1013g-img1322-014-section_depth_resolution

parallel-img1322-post9unreviewed · inferred

section_linear_weight_candidate

do

25 lb/ft

W408 penthouse-post row P9, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. lb/ft is conventional @-weight interpretation; no governing weight unit found in this crop.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: do

W408 penthouse-post row P9, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. lb/ft is conventional @-weight interpretation; no governing weight unit found in this crop.

Calculated from: structsched1013g-img1322-016-scheduled_section_notation_resolution, structsched1013g-img1322-015-section_linear_weight_candidate

parallel-img1322-post10verified · printed

scheduled_section_notation_resolution

do

W408 penthouse-post row P10, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: do

W408 penthouse-post row P10, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention.

Calculated from: structsched1013g-img1322-013-scheduled_section_notation_resolution

parallel-img1322-post10verified · printed

section_depth_resolution

do

6 in

W408 penthouse-post row P10, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. Inch mark explicitly printed at governing P8 cell.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: do

W408 penthouse-post row P10, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. Inch mark explicitly printed at governing P8 cell.

Calculated from: structsched1013g-img1322-019-scheduled_section_notation_resolution, structsched1013g-img1322-013-scheduled_section_notation_resolution, structsched1013g-img1322-014-section_depth_resolution

parallel-img1322-post10unreviewed · inferred

section_linear_weight_candidate

do

25 lb/ft

W408 penthouse-post row P10, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. lb/ft is conventional @-weight interpretation; no governing weight unit found in this crop.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: do

W408 penthouse-post row P10, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. lb/ft is conventional @-weight interpretation; no governing weight unit found in this crop.

Calculated from: structsched1013g-img1322-019-scheduled_section_notation_resolution, structsched1013g-img1322-015-section_linear_weight_candidate

parallel-img1322-post11verified · printed

scheduled_section_notation_resolution

do

W408 penthouse-post row P11, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: do

W408 penthouse-post row P11, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention.

Calculated from: structsched1013g-img1322-013-scheduled_section_notation_resolution

parallel-img1322-post11verified · printed

section_depth_resolution

do

6 in

W408 penthouse-post row P11, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. Inch mark explicitly printed at governing P8 cell.

IMG_1322 · W-408 · Locate on drawing ↗

Drawing notation: do

W408 penthouse-post row P11, printed do cell inherits 6″ H @25 from P8; no intervening non-ditto size before P17. Same row as earlier source record; no revision line/color intervention. Inch mark explicitly printed at governing P8 cell.

Calculated from: structsched1013g-img1322-022-scheduled_section_notation_resolution, structsched1013g-img1322-013-scheduled_section_notation_resolution, structsched1013g-img1322-014-section_depth_resolution

View all source photographs →