Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
struct-gap-img1321-cornice-row-5needs-review · printed
beam_d_section_notation
12 I @[40.8?]I-section glyph normalized as I; section weight and grouped-count uncertainties retained literally. No individual installed beam identity established.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: 12 I @[40.8?]
I-section glyph normalized as I; section weight and grouped-count uncertainties retained literally. No individual installed beam identity established.
struct-gap-img1321-lightcourt-short-detailverified · printed
depicted_span_applicability
SECTION FOR 13′, 14′ AND 15′ SPANSPrinted local annotation; registration and applicability remain unaccepted.
struct-gap-img1321-lightcourt-short-detailunreviewed · printed
connection_rivet_spacing
3″ O.C. TWO RIVETS AT EA. POINT CSK OUTSIDE3 in
Printed local annotation; registration and applicability remain unaccepted. Review correction review-correction-20261013m-struct-gap-20261012k-1321-m035: Same W407 light-court section fastener/fill-point line explicitly prints 3′-0″ O.C.; prior transcription recorded 3 in. Crop preserves the foot mark, zero-inch component and two-rivet instruction. This is a same-image notation/unit correction candidate only; prior reading retained and no historical revision or physical geometry selected.
struct-gap-img1321-lightcourt-short-detailverified · printed
connection_rivets_per_point
TWO RIVETS AT EA. POINT2 count
Printed local annotation; registration and applicability remain unaccepted.
struct-gap-img1321-lightcourt-short-detailverified · printed
connection_rivet_head_treatment
CSK OUTSIDEPrinted local annotation; registration and applicability remain unaccepted.
struct-gap-img1321-lightcourt-short-detailverified · printed
lower_horizontal_witness
7″7 in
Printed local annotation; registration and applicability remain unaccepted.
struct-gap-img1321-lightcourt-short-detailneeds-review · printed
connection_angle_fraction
7 × 3½ × [fraction unresolved] LAngle first and second legs appear 7 and 3½; thickness remains unreadable and dimensions not assigned independently.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: 7 × 3½ × [fraction unresolved] L
Angle first and second legs appear 7 and 3½; thickness remains unreadable and dimensions not assigned independently.
struct-gap-img1321-lightcourt-long-detailverified · printed
depicted_span_applicability
SECTION FOR 21′ SPANS21 ft
Printed caption conflicts in apparent span grouping with cornice schedule row 22′7″. Do not collapse or match the two regions.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: SECTION FOR 21′ SPANS
Printed caption conflicts in apparent span grouping with cornice schedule row 22′7″. Do not collapse or match the two regions.
struct-gap-img1321-lightcourt-long-detailunreviewed · printed
connection_rivet_spacing
3″ O.C. TWO RIVETS AT EA. POINT CSK OUTSIDE3 in
Printed local annotation; registration and applicability remain unaccepted. Review correction review-correction-20261013m-struct-gap-20261012k-1321-m041: Same W407 light-court section fastener/fill-point line explicitly prints 3′-0″ O.C.; prior transcription recorded 3 in. Crop preserves the foot mark, zero-inch component and two-rivet instruction. This is a same-image notation/unit correction candidate only; prior reading retained and no historical revision or physical geometry selected.
struct-gap-img1321-lightcourt-long-detailverified · printed
connection_rivets_per_point
TWO RIVETS AT EA. POINT2 count
Printed local annotation; registration and applicability remain unaccepted.
struct-gap-img1321-lightcourt-long-detailverified · printed
connection_rivet_head_treatment
CSK OUTSIDEPrinted local annotation; registration and applicability remain unaccepted.
struct-gap-img1321-lightcourt-long-detailverified · printed
lower_horizontal_witness
7″7 in
Printed local annotation; registration and applicability remain unaccepted.
struct-gap-img1321-companion-noteverified · printed
omitted_framing_companion_reference
NOTE: FOR FRAMING OF FAN ROOM AND ELEVATOR MACHINE ROOM NOT SHOWN ON THIS DRAWING SEE DRAWINGS NOS. 406 & 408Printed local annotation; registration and applicability remain unaccepted.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: NOTE: FOR FRAMING OF FAN ROOM AND ELEVATOR MACHINE ROOM NOT SHOWN ON THIS DRAWING SEE DRAWINGS NOS. 406 & 408
Printed local annotation; registration and applicability remain unaccepted.
struct-gap-img1321-cornice-row-4verified · printed
beam_a_section_notation_resolution
2 12″ I @20.7Literal scheduled designation only. @ suffix has no printed unit in this crop; do not infer a modern section, placed beam or governing steel grade.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: 2 12″ I @20.7
Literal scheduled designation only. @ suffix has no printed unit in this crop; do not infer a modern section, placed beam or governing steel grade.
struct-gap-img1321-cornice-row-5verified · printed
beam_b_section_notation_resolution
15″ I @42.9Literal scheduled designation only. @ suffix has no printed unit in this crop; do not infer a modern section, placed beam or governing steel grade.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: 15″ I @42.9
Literal scheduled designation only. @ suffix has no printed unit in this crop; do not infer a modern section, placed beam or governing steel grade.
struct-gap-img1321-cornice-row-5verified · printed
beam_c_section_notation_resolution
12″ I @40.8Literal scheduled designation only. @ suffix has no printed unit in this crop; do not infer a modern section, placed beam or governing steel grade.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: 12″ I @40.8
Literal scheduled designation only. @ suffix has no printed unit in this crop; do not infer a modern section, placed beam or governing steel grade.
struct-gap-img1321-cornice-row-5verified · printed
beam_d_section_notation_resolution
12″ I @40.8Literal scheduled designation only. @ suffix has no printed unit in this crop; do not infer a modern section, placed beam or governing steel grade.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: 12″ I @40.8
Literal scheduled designation only. @ suffix has no printed unit in this crop; do not infer a modern section, placed beam or governing steel grade.
structsched1013g-img1321-cornice-sectionverified · printed
upper_vertical_witness
3′-10″46 in
Section-local vertical witness from upper reference line at high-of-roof line to intermediate B-beam line. Not accepted member length or roof datum transform.
IMG_1321 · W-407 · Locate on drawing ↗Drawing notation: 3′-10″
Section-local vertical witness from upper reference line at high-of-roof line to intermediate B-beam line. Not accepted member length or roof datum transform.
structsched1013g-img1321-cornice-sectionverified · printed
anchor_spacing_notation
¾ φ ANCHORS 6′-0″ O.C.Lower C-beam anchor note; nominal round bar notation, not installed quantity.
structsched1013g-img1321-cornice-sectionverified · printed
anchor_spacing
6′-0″ O.C.72 in
Lower C-beam anchors, printed section spacing only.