Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
beam-W404-main-95-96-inner-1verified · derived
support span
15.583333333333343 ft15.583333 ft
Distance between named support axes, not physical cut length or clear span.
Calculated from: column-95-registered-world-x, column-95-registered-world-z, column-96-registered-world-x, column-96-registered-world-z
beam-W404-main-95-96-inner-1verified · printed
top steel offset
-6 in-6 in
beam-W404-main-95-96-inner-1verified · derived
top steel elevation
159.75 ft159.75 ft
Applies to this member's printed steel tag only; not a slab elevation.
Calculated from: beam-W404-main-95-96-inner-1-top-steel-offset, frame-sixth-floor-finish
beam-W404-main-95-96-inner-1unreviewed · observed
cut length
UnresolvedNumeric value unresolved
beam-W404-main-95-96-inner-1unreviewed · observed
steel grade
Unresolvedbeam-W404-main-95-96-inner-2verified · observed
material
steelExplicit steel-elevation convention and drawn rolled-metal profiles; grade is not stated.
beam-W404-main-95-96-inner-2illegible · observed
profile symbol
Unresolvedbeam-W404-main-95-96-inner-2verified · printed
nominal depth
10 in10 in
beam-W404-main-95-96-inner-2unreviewed · inferred
weight per length
25.4 lb/ft25.4 lb/ft
Numeric mark following @ is read directly; pounds per foot is the conventional interpretation of historic rolled-beam notation, not an explicitly printed unit in the inspected region.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: 2 10″ [section symbol unresolved] @ 25.4 −6″
Numeric mark following @ is read directly; pounds per foot is the conventional interpretation of historic rolled-beam notation, not an explicitly printed unit in the inspected region.
beam-W404-main-95-96-inner-2verified · derived
support span
15.583333333333343 ft15.583333 ft
Distance between named support axes, not physical cut length or clear span.
Calculated from: column-95-registered-world-x, column-95-registered-world-z, column-96-registered-world-x, column-96-registered-world-z
beam-W404-main-95-96-inner-2verified · printed
top steel offset
-6 in-6 in
beam-W404-main-95-96-inner-2verified · derived
top steel elevation
159.75 ft159.75 ft
Applies to this member's printed steel tag only; not a slab elevation.
Calculated from: beam-W404-main-95-96-inner-2-top-steel-offset, frame-sixth-floor-finish
beam-W404-main-95-96-inner-2unreviewed · observed
cut length
UnresolvedNumeric value unresolved
beam-W404-main-95-96-inner-2unreviewed · observed
steel grade
Unresolvedbeam-W404-main-95-96-outerverified · observed
material
steelExplicit steel-elevation convention and drawn rolled-metal profiles; grade is not stated.
beam-W404-main-95-96-outerverified · printed
profile symbol
Ibeam-W404-main-95-96-outerverified · printed
nominal depth
12 in12 in
beam-W404-main-95-96-outerunreviewed · inferred
weight per length
40.8 lb/ft40.8 lb/ft
Numeric mark following @ is read directly; pounds per foot is the conventional interpretation of historic rolled-beam notation, not an explicitly printed unit in the inspected region.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: 12″ I @ 40.8 -5″; 12 × 5/16 PL.
Numeric mark following @ is read directly; pounds per foot is the conventional interpretation of historic rolled-beam notation, not an explicitly printed unit in the inspected region.
beam-W404-main-95-96-outerverified · derived
support span
15.583333333333343 ft15.583333 ft
Distance between named support axes, not physical cut length or clear span.
Calculated from: column-95-registered-world-x, column-95-registered-world-z, column-96-registered-world-x, column-96-registered-world-z
beam-W404-main-95-96-outerverified · printed
top steel offset
-5 in-5 in
beam-W404-main-95-96-outerverified · derived
top steel elevation
159.83333333333334 ft159.833333 ft
Applies to this member's printed steel tag only; not a slab elevation.
Calculated from: beam-W404-main-95-96-outer-top-steel-offset, frame-sixth-floor-finish
beam-W404-main-95-96-outerunreviewed · observed
cut length
UnresolvedNumeric value unresolved
beam-W404-main-95-96-outerunreviewed · observed
steel grade
Unresolvedplate-W404-main-95-96verified · printed
width
12 in12 in
plate-W404-main-95-96verified · printed
thickness
0.3125 in0.3125 in
plate-W404-main-95-96illegible · observed
length
UnresolvedNumeric value unresolved
floor-assembly-W404verified · printed
finish floor elevation
160.25 ft160.25 ft
floor-assembly-W404verified · printed
floor fill thickness
4 in4 in
floor-assembly-W404verified · printed
lower slab thickness
3.5 in3.5 in
detail-W404-exterior-wall-14ftverified · printed
stone face to column axis offset
10 in10 in
Section-local offset; no automatic application to corner or Main/Madison frontages.
detail-W404-exterior-wall-22ft7verified · printed
stone face to column axis offset
22 in22 in
Different local outside-wall/steel assembly from the 14-foot-span section; its profile/plate details are not generalized.
IMG_1318 · sheet-W404 · Locate on drawing ↗Drawing notation: SECTION THRU 22′7″ SPAN FROM COL84 TO96
Different local outside-wall/steel assembly from the 14-foot-span section; its profile/plate details are not generalized.
broadway-wall-face-middle-w404verified · printed
stoneFace.outwardOffsetFromColumnCenterline
10″10 in
Explicit section applicability to14-foot spans from C26 toC70.
broadway-wall-face-middle-w404verified · derived
stoneFace.sectionReferenceWorldX
78′7″ + 10″ = 79′5″79.416667 ft
Exact arithmetic for the identified local section reference. Acceptance does not extend to a full-height plane, a pier projection or an opening reveal.
Calculated from: structural-registration-origin-half-span, bway-plane-w404-middle-offset
broadway-wall-face-middle-w404verified · printed
exteriorReference.material
FACE OF STONEStone type, finish and bed thickness are not established.
broadway-wall-face-middle-w404unreviewed · observed
wall.thickness
Full masonry wall thickness not dimensioned in this beam sectionNumeric value unresolved
broadway-wall-face-middle-w404unreviewed · observed
wall.interiorFaceWorldX
Interior wall/finish face not resolvedNumeric value unresolved
broadway-wall-face-middle-w404unreviewed · observed
opening.revealDepth
Window/reveal depth not resolvedNumeric value unresolved
broadway-wall-face-middle-w404unreviewed · observed
wall.verticalExtentBottom
Section does not define the bottom of a whole-height facade faceNumeric value unresolved
broadway-wall-face-middle-w404unreviewed · observed
wall.verticalExtentTop
Section does not define the top of a whole-height facade faceNumeric value unresolved
broadway-wall-face-north-w404verified · printed
stoneFace.outwardOffsetFromColumnCenterline
1′10″22 in
Explicit section applicability to22′7″ span C84–C96.