Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1316 · Folder 186

3rd Floor Framing Plan

Sheet W402

Extraction: Reviewed · extraction partial. C10/C11/C12 perimeter spans, C68/C82 connected framing paths, and C70/C72/C84 local perimeter spans. W400 includes C84/C96 terminal span. Partial timed visual review: Bounded source-reading review only; no full-source or geometry acceptance. Partial timed visual review: Text-only reuse, no new visual inspection. Partial timed visual review: Access derivative actually sideways. Recorded regions remain encoded access-image coordinates; rotate clockwise 270 degrees to read. Existing C68/C82 controls reused. Partial timed visual review: Targeted source detail only. Master orientation recorded independently from access derivatives. Region bounds are crop locators, not physical geometry. Partial timed visual review: undefined Partial timed visual review: undefined

Unresolved extraction work
  • All other framing and connections
  • Interior column center eccentricities and control-offset ties
  • Vertical column continuation
  • Whole-sheet dimensions and local exceptions
  • The source-local 7-inch lower horizontal, 1-foot2-inch upper horizontal and 5-inch floor offset witnesses do not establish the complete wall layer/material chain. detail-20261011n-img1316-wall_layer_dimensions remains open.
  • Complete source-to-instance registration, physical endpoints and installed quantities remain unresolved.
  • Unreviewed sheet regions, fine notes, schedules, companion applicability and revision authority remain open.
  • No world coordinates, member cut lengths, steel grades, physical wall geometry or architectural acceptance established.
  • Existing21-foot-span local dimensions do not close full wall-layer dimensions. Column-center offsets and framing incidence/registration remain open. No repeat native view.
  • Installed instance allocation, quantities and source-to-building registration remain unresolved.
  • All remaining dimensions, profiles, joints, finishes and companion/revision applicability need review.
  • No accepted physical geometry or whole-source completeness established.
  • All remaining small dimension chains and endpoint classifications
  • Complete profiles, quantities and installation registration
  • Companion details and original/revision reconciliation
  • Independent geometry/model check and as-built correspondence
  • Remaining dimension endpoints and layer/material assignments not yet reviewed
  • Installed instances, quantities and plan/elevation registration unresolved
  • Companion details and revisions require reconciliation
  • Independent model/as-built checks unavailable in this extraction
  • Other wall-profile fractions and layer endpoints remain unreadable or unreviewed.
  • Exact fill outline, material grade and installed quantity await fabrication/companion evidence.
  • Other sheet regions, fine notes, schedules, callouts and revisions remain unreviewed.
  • Complete source-to-instance registration, connection capacities, material grades and independent model/as-built checks remain pending.
  • Installed angle quantities and individual bay lengths not extracted
  • Material specification and fastening not established by these notes
  • Remaining framing marks, schedules, revisions and companion slab sheet W-413 require review
  • Source-to-model and as-built checks remain pending

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

51 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

control-w402-interior-68-82verified · printed

perimeter.span.C10.C11

14′0″

14 ft

Printed perimeter-support span. This does not itself dimension an interior support.

control-w402-interior-68-82verified · printed

perimeter.span.C11.C12

15′7″

15.583333 ft

Printed perimeter-support span. This does not itself dimension an interior support.

control-w402-interior-68-82verified · printed

perimeter.span.C70.C72

14′0″

14 ft

Printed perimeter-support span. This does not itself dimension an interior support.

control-w402-interior-68-82verified · printed

perimeter.span.C72.C84

14′0″

14 ft

Printed perimeter-support span. This does not itself dimension an interior support.

control-w402-interior-68-82unreviewed · observed

framing.observedLongitudinalIncidence

A connected, apparently straight beam/girder line passes through the drawn support symbols C10, C68, C82 and C94.

Observed structural incidence, not a printed zero transverse offset. Only the endpoint/support identities C10/C68/C82/C94 are assigned; intermediate marks are not transcribed in this bounded task.

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C10 to C68 longitudinal framing path

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C68, C82, C94 framing path

column-68unreviewed · derived

coordinationCandidate.worldX

49′0″, conditional on zero column-center offset from the C10/C94 longitudinal framing line

49 ft

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C10–C68 framing path

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C68–C82–C94 framing path

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C68–C82–C94 framing path

Calculated from: interior-68-82-w400-perimeter-x-station, interior-68-82-w402-perimeter-x-station, interior-68-82-w400-longitudinal-framing-incidence, interior-68-82-w402-longitudinal-framing-incidence, assumption-interior-longitudinal-framing-line-equals-column-control

column-68unreviewed · derived

coordinationCandidate.worldZ

28′0″, conditional on zero column-center offset from the transverse C68/C70 framing line

28 ft

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C68 transverse line

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C68 transverse line

Calculated from: interior-68-82-w400-perimeter-z-70, interior-68-82-w402-perimeter-z-70, interior-68-82-w400-transverse-68-70, interior-68-82-w402-transverse-68-70, assumption-column-68-transverse-line-equals-column-control

column-68unreviewed · observed

columnCenter.offsetFromFramingReferenceX

Unresolved column-control X offset from the nominal framing reference

Numeric value unresolved

No numeric offset is inferred from image pixels or from the foundation trace. Null does not mean zero.

column-68unreviewed · observed

columnCenter.offsetFromFramingReferenceZ

Unresolved column-control Z offset from the nominal framing reference

Numeric value unresolved

No numeric offset is inferred from image pixels or from the foundation trace. Null does not mean zero.

column-82unreviewed · derived

coordinationCandidate.worldX

49′0″, conditional on zero column-center offset from the C10/C94 longitudinal framing line

49 ft

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C10–C68 framing path

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C68–C82–C94 framing path

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C68–C82–C94 framing path

Calculated from: interior-68-82-w400-perimeter-x-station, interior-68-82-w402-perimeter-x-station, interior-68-82-w400-longitudinal-framing-incidence, interior-68-82-w402-longitudinal-framing-incidence, assumption-interior-longitudinal-framing-line-equals-column-control

column-82unreviewed · derived

coordinationCandidate.worldZ

56′0″, conditional on zero column-center offset from the transverse C82/C84 framing line

56 ft

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C82 transverse line

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C82 transverse line

Calculated from: interior-68-82-w400-perimeter-z-84, interior-68-82-w400-transverse-82-84, interior-68-82-w402-transverse-82-84, assumption-column-82-transverse-line-equals-column-control

column-82unreviewed · observed

columnCenter.offsetFromFramingReferenceX

Unresolved column-control X offset from the nominal framing reference

Numeric value unresolved

No numeric offset is inferred from image pixels or from the foundation trace. Null does not mean zero.

column-82unreviewed · observed

columnCenter.offsetFromFramingReferenceZ

Unresolved column-control Z offset from the nominal framing reference

Numeric value unresolved

No numeric offset is inferred from image pixels or from the foundation trace. Null does not mean zero.

column-68unreviewed · inferred

Unaccepted framing incidence assumption

The connected longitudinal framing path through C10/C68/C82/C94 coincides with the exact column-control axis without an unmarked transverse offset.

The drawn beam/girder line may describe a member line or framing connection rather than the exact center of an eccentrically connected column. Schematic one-line representations do not prove zero eccentricity.

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C10–C68 framing path

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C68–C82–C94 framing path

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C68–C82–C94 framing path

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C10–C68 framing path

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C68–C82–C94 framing path

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C68–C82–C94 framing path

column-68unreviewed · inferred

Unaccepted framing incidence assumption

Transverse framing line through C68 and perimeter C70 supplies the same Z control to both column centers.

An eccentric attachment, unrecorded local center offset or schematic beam endpoint may differ from the actual column-control center.

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C68 transverse line

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C68 transverse line

column-82unreviewed · inferred

Unaccepted framing incidence assumption

Transverse framing line through C82 and perimeter C84 supplies the same Z control to both column centers.

An eccentric attachment, unrecorded local center offset or schematic beam endpoint may differ from the actual column-control center.

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: C82 transverse line

IMG_1316 · sheet-W402 · Locate on drawing ↗

Drawing notation: C82 transverse line

detail-img1316-light-court-wall-sectionverified · printed

span21_lower_horizontal_witness

7″

7 in

Lower horizontal dimension witness in right SECTION FOR 21′ SPANS, between depicted lower member-side and vertical reference extensions. Not full wall thickness or accepted profile.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: 7″

Lower horizontal dimension witness in right SECTION FOR 21′ SPANS, between depicted lower member-side and vertical reference extensions. Not full wall thickness or accepted profile.

detail-img1316-light-court-wall-sectionverified · printed

span21_upper_horizontal_witness

1′-2″

14 in

Upper horizontal dimension witness in right SECTION FOR 21′ SPANS. Physical layer boundaries and full wall construction remain unresolved.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: 1′-2″

Upper horizontal dimension witness in right SECTION FOR 21′ SPANS. Physical layer boundaries and full wall construction remain unresolved.

detail-img1316-light-court-wall-sectionverified · printed

span21_floor_level_offset_witness

5″

5 in

Vertical source witness immediately below printed 3D.FL.LEVEL in right 21-foot-span section; no universal slab depth or room elevation inferred.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: 5″

Vertical source witness immediately below printed 3D.FL.LEVEL in right 21-foot-span section; no universal slab depth or room elevation inferred.

detail-img1316-light-court-wall-sectionverified · printed

section_application_span

SECTION FOR 21′ SPANS

21 ft

Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: SECTION FOR 21′ SPANS

Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.

detail-img1316-light-court-wall-sectionunreviewed · printed

wall_layer_dimensions

[wall layer/profile dimensions require targeted master crop]

Numeric value unresolved

Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: [wall layer/profile dimensions require targeted master crop]

Printed detail-local property; no accepted building placement, historical quantity or exact room geometry inferred.

detail-img1316-outside-wall-typicalverified · printed

face_stone_to_column_axis

1′-10″

22 in

Named FACE OF STONE to C.L. OF COL. dimension; does not establish interior wall face or total wall thickness.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: 1′-10″

Named FACE OF STONE to C.L. OF COL. dimension; does not establish interior wall face or total wall thickness.

detail-img1316-outside-wall-typicalverified · printed

bracket_spacing

L-BRACKETS ABT. 2′-6″ O.C.

30 in

Explicit approximate spacing (ABT.); not exact installed quantity.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: L-BRACKETS ABT. 2′-6″ O.C.

Explicit approximate spacing (ABT.); not exact installed quantity.

detail-img1316-outside-wall-typicalverified · printed

bracket_section_family

L-BRACKETS

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: L-BRACKETS

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

detail-img1316-outside-wall-22ft7verified · printed

section_application_span

SECTION FOR 22′-7″ SPANS

271 in

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: SECTION FOR 22′-7″ SPANS

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

detail-img1316-outside-wall-22ft7verified · printed

face_stone_to_column_axis

1′-10″

22 in

Named FACE OF STONE to C.L. OF COL. dimension; does not establish interior wall face or total wall thickness.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: 1′-10″

Named FACE OF STONE to C.L. OF COL. dimension; does not establish interior wall face or total wall thickness.

detail-img1316-outside-wall-22ft7verified · printed

bracket_spacing

L-BRACKETS ABT. 3′-0″ O.C.

36 in

Explicit approximate spacing (ABT.); not exact installed quantity.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: L-BRACKETS ABT. 3′-0″ O.C.

Explicit approximate spacing (ABT.); not exact installed quantity.

detail-img1316-outside-wall-22ft7verified · printed

bracket_section_family

L-BRACKETS

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: L-BRACKETS

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

detail-img1316-outside-wall-15ft7verified · printed

section_application_span

SECTION FOR 15′-7″ SPANS

187 in

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: SECTION FOR 15′-7″ SPANS

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

detail-img1316-outside-wall-15ft7verified · printed

face_stone_to_column_axis

1′-10″

22 in

Named FACE OF STONE to C.L. OF COL. dimension; does not establish interior wall face or total wall thickness.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: 1′-10″

Named FACE OF STONE to C.L. OF COL. dimension; does not establish interior wall face or total wall thickness.

detail-img1316-outside-wall-15ft7verified · printed

bracket_spacing

L-BRACKETS ABT. 2′-6″ O.C.

30 in

Explicit approximate spacing (ABT.); not exact installed quantity.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: L-BRACKETS ABT. 2′-6″ O.C.

Explicit approximate spacing (ABT.); not exact installed quantity.

detail-img1316-outside-wall-15ft7verified · printed

bracket_section_family

L-BRACKETS

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

IMG_1316 · W-402 · Locate on drawing ↗

Drawing notation: L-BRACKETS

Printed detail-local property; installation assignment and physical endpoint registration remain unresolved.

View all source photographs →