Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1303 · Folder 187

Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks

Sheet W-215

Extraction: Reviewed · extraction partial. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks. Normalized from an existing text re-audit; this import did not reopen the source image. Partial timed visual review: undefined Partial timed visual review: Printed source-local specification/detail only. No installed quantity, accepted room geometry or building transform established; no cross-sheet revision equivalence assumed. Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: Source-local regional inventory and bounded companion findings; architecture and exhaustive extraction unapproved.

Highlighted reading: 10′-2½″. Lower long horizontal witness between the two drawn endpoint extension lines in Bay B plan; no operating-clear or overall installed screen classification. Source-local evidence only; no accepted installed geometry, quantity, revision precedence or world placement.

Show every recorded property on this drawing →

Unresolved extraction work
  • Complete drawing-note transcription
  • Every dimension and bay placement
  • Detailed hardware/fastener schedule
  • Exact cross-sheet bay correspondence
  • Cross-photo physical deduplication
  • Complete surviving-object inventory
  • Exact dimensions
  • Construction/alteration chronology
  • Condition assessment
  • P-6 component extraction
  • Installed fixture schedule and positions
  • As-built correspondence
  • Fixture finish and glass color
  • Text-only reuse; no new evidence selected for shared material/world-transform questions.
  • Remaining uninspected notes, dimensions, schedules, details and companion sheets require separate review.
  • Original versus revision authority, installed instance correspondence and source-to-building registration remain unresolved.
  • No closed physical profile or architectural/model acceptance established.
  • All other fine dimensions and endpoint classes remain to be reviewed
  • Installed instance quantity, exact room/bay coordinates and source-to-building registration unresolved
  • Original approval/revision fields and cleaner companion captures require separate reconciliation
  • Unmeasured curve radii, moulding endpoints and closed physical profiles remain null; photographic tracing is not a dimension.
  • Original versus revision authority, installed quantities and source-to-room/bay registration remain unresolved.
  • Companion details, fixing schedules, actual installed finishes and as-built correspondence remain open.
  • Remaining dimensions, fine fractions, notes, schedules and companion details are not exhaustively extracted.
  • Installed quantities, accepted room/bay placement and source-to-building registration remain unresolved.
  • Original/revision authority, actual finish and physical profile applicability remain unresolved; modeling/checking unchecked.
  • Small Bay K flap-hinge/fastening, bracing and blocking note text still requires targeted review; exact material sizes and all endpoint chains remain incomplete.
  • Remaining fine dimension fractions and witness endpoint classes require targeted master crops; standard inventory does not certify exhaustive extraction.
  • All notes, material-code keys, schedules, approval/date/revision fields and companion references need complete transcription and reconciliation.
  • Exact installed quantities, room/bay placement, source-to-building registration, physical layer/profiles and as-built correspondence remain unresolved.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. The gold outline locates the selected reading. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

1 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

lobbyenv1014x-w215-bay-b-counterverified · printed

plan_outer_witness_span

10′-2½″

122.5 in

Lower long horizontal witness between the two drawn endpoint extension lines in Bay B plan; no operating-clear or overall installed screen classification. Source-local evidence only; no accepted installed geometry, quantity, revision precedence or world placement.

IMG_1303 · W-215 · Locate on drawing ↗

Drawing notation: 10′-2½″

Lower long horizontal witness between the two drawn endpoint extension lines in Bay B plan; no operating-clear or overall installed screen classification. Source-local evidence only; no accepted installed geometry, quantity, revision precedence or world placement.

View all source photographs →