Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1296 · Folder 187

Ornamental pendant-light elevations

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial first-pass visual review of public/archive/drawings/complete-upright/IMG_1296.webp using <=1000px quality65 JPEG locator after OCR/catalogue. Regions refer to the unchanged orientation access image; actual required reading rotation recorded. Fine notes remain unresolved when locator resolution insufficient. Partial timed visual review: Additive bounded follow-up after queue, OCR and prior packages; prior verified readings reused without duplication. No full-sheet completion or model acceptance. Partial timed visual review: Additive detailed review of selected regions following OCR and prior packages. Type-level evidence only; no installed position or quantity established. Other fine regions remain partial. Partial timed visual review: Bounded additive fine-note review of upright WebP, one sequential image inspection. Prior packages and OCR consulted first; no full coverage claim. Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: Depicted type/component, shop order or source-local assembly only. Components and grille order quantities do not create installed fixtures or establish electrical outlet-to-type assignments. Partial timed visual review: undefined Partial timed visual review: Text-only reconciliation of prior verified packages and OCR. No new measurement, region-completion claim or physical instance created. Partial timed visual review: undefined Partial timed visual review: undefined

Unresolved extraction work
  • full-sheet completeness
  • remaining fine notes, dimensions, callouts and annotations
  • element-to-floor and companion sheet registration
  • Full remaining regional note and dimension review
  • Companion installation schedule and original installed quantities
  • Source-to-installed-instance registration and as-built correspondence
  • remaining unreadable fractions and dimensional endpoints
  • complete companion installation schedule and original quantities
  • source-to-installed-instance registration
  • Remaining small fractions and profile dimensions
  • Companion installation schedule and installed quantities
  • Installed physical instances, original quantities, room/floor hosts, anchors and checked source-to-building registration unresolved.
  • Original/revision and as-built applicability require companion review; no layer selected.
  • Remaining profile dimensions, glass thickness, envelope/endpoints, notes, schedules, cutoffs and companion details remain partial; modeling unchecked.
  • Installed quantities, room/floor hosts, mounting stations, checked registration and as-built correspondence remain unresolved.
  • Revision authority, remaining fine notes, dimensions and companion schedules require review.
  • Glass thickness, physical endpoints and overall envelopes remain unestablished; no modeling/checking or architectural acceptance.
  • Type579 chain first denominator remains unresolved after earlier native crops; no higher-quality evidence found and no reopen. Right general-note lines physically clipped.
  • Full regional coverage and independent dimensional checks.
  • Installed schedule, original/as-built correspondence, floor/room hosts, stations and checked source transforms.
  • Historical issue/revision authority and whole-building modeling checks.
  • Installed source-to-element registration, actual quantities, floor/room hosts and as-built correspondence
  • Governing issue/revision authority and original versus archive annotation reconciliation
  • All residual fine profiles, dimensions, callouts, schedules, companion details and clipped margins remain partial
  • No new properties from this source; prior fine-profile and installation gaps retained
  • Remaining fine fractions, outline profiles, machining endpoints and marginal handwriting require targeted master review.
  • Full companion and revision authority audit remains open.
  • Installed instance quantities, room/floor placement, hosts and source-to-building registration are unestablished.
  • 6½in canopy,No14 B&S ring,3No8-32 screws and556glass ref reused; full profile open.
  • 9in side backplate and7in globe axis projection added; front6in plate and counts reused. Fine arms/gas fittings open.
  • Collar3No8-32 screws added. Known11in plate,10in projection,segments andtwo burners reused. Supply still schedule conditional.
  • Known5¼in ring,six¼in vents,No14 B&S,3No8-32 screws andporcelainreceptacle reused. Profile envelope open.
  • Known6½in canopy,four chains/four leaves andmaterial notes reused; width/stock added null. Chain triplets unresolved.
  • General-note endings physically cropped in this exposure. Complete companion/sheet needed; no complete specification inferred.
  • Fine drawing dimensions/profile endpoints not exhaustively extracted; no physical thickness inferred from gauges.
  • Installed fixture key, room/station assignment, quantity, host/anchor and checked registration remain unresolved.
  • Original versus annotated revision authority and clipped sheet edges require review.
  • Known canopy/plate/gauge/screw/glass properties reused; selected new component quantity/dimension only.
  • Small chain fractions, full type envelope,component profiles,glass thickness and installation schedule remain unresolved.
  • Right-edge general note lines physically truncated; do not promote incomplete clauses to full specifications.
  • Find complete sheet/neighbor exposure; governing burner/glassware conditions await complete note.
  • Remaining fine regions, notes, schedules, callouts and colored revisions require review.
  • Governing installation schedule, original quantities, room registration and as-built correspondence unresolved.
  • Modeling/checking unchecked; no accepted world coordinates.
  • Current lighting task has no newly verified outlet-to-type key in this source; retain discipline and prior source scope.
  • Installed instances, quantities, room/floor hosts, mounting and accepted source-to-building registration remain unresolved.
  • Original/revision authority and companion specifications remain unresolved.
  • Unvisited regions, dimensions, schedules, margins and notes remain partial; modeling/checking unchecked.
  • Installed quantities, floor/room hosts, mounting stations and accepted source-to-building registration remain unresolved.
  • Governing issue/revision and installed/as-built correspondence require companion schedule evidence.
  • Remaining fine dimensions, profiles, notes and margins are partial; modeling/checking unchecked.
  • Previously failed chain-length denominator not reopened without better evidence. Right general-note endings remain physically clipped; companion note needed.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

53 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1296-assemblyverified · printed

fixture_559_type

559

559 identifier

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: 559

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_559_glass_reference

GLASSWARE LIKE ON 556

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: GLASSWARE LIKE ON 556

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_560_type

560

560 identifier

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: 560

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_560_mounting

SIDE ELEVATION OF ONE ARM FIXTURE

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: SIDE ELEVATION OF ONE ARM FIXTURE

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_576_supply_note

GAS OR ELECTRIC AS NOTED IN SCHEDULE

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: GAS OR ELECTRIC AS NOTED IN SCHEDULE

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_576_glazing

DEEP ETCHED ALABASTER GLASS RAISED ORNAMENTATION

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: DEEP ETCHED ALABASTER GLASS RAISED ORNAMENTATION

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_578_construction

CAST HAND FINISHED

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: CAST HAND FINISHED

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_578_glazing

DEEP ETCHED ALABASTER GLASS RAISED ORNAMENTATION

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: DEEP ETCHED ALABASTER GLASS RAISED ORNAMENTATION

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_579_cord

REINFORCED SILK COVERED CORD FINISH TO MATCH FIXTURE

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: REINFORCED SILK COVERED CORD FINISH TO MATCH FIXTURE

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_579_conductor_routing

SINGLE CONDUCTORS TO MATCH FINISH INTERLACED IN CHAIN

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: SINGLE CONDUCTORS TO MATCH FINISH INTERLACED IN CHAIN

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_579_socket

PORCELAIN SOCKET TO BE STANDARD SIZE UNLESS OTHERWISE NOTED IN SPECIFICATION

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: PORCELAIN SOCKET TO BE STANDARD SIZE UNLESS OTHERWISE NOTED IN SPECIFICATION

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_579_glazing

DEEP ETCHED ALABASTER GLASS RAISED ORNAMENTATION

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: DEEP ETCHED ALABASTER GLASS RAISED ORNAMENTATION

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_579_leaves_quantity

4 LEAVES

4 leaves

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: 4 LEAVES

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyverified · printed

fixture_579_bushing_material

RUBBER BUSHING

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

IMG_1296 · Locate on drawing ↗

Drawing notation: RUBBER BUSHING

Selected visually legible property; type/detail-local scope; no building quantity or room geometry inference.

parallel-img1296-assemblyunreviewed · printed

general_notes_unresolved

[general notes at lower right cropped]

OCR locator or small tentative text; withheld numeric value and crop verification required.

IMG_1296 · Locate on drawing ↗

Drawing notation: [general notes at lower right cropped]

OCR locator or small tentative text; withheld numeric value and crop verification required.

detail-lighting-img1296-560verified · printed

canopy_parent

CANOPY LIKE ON 557

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: CANOPY LIKE ON 557

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-560verified · printed

backplate_width

6"

6 in

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: 6"

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-560verified · printed

backplate_screw_quantity

4 SCREWS

4 count

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: 4 SCREWS

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-576verified · printed

backplate_height

11"

11 in

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: 11"

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-576verified · printed

horizontal_projection

10"

10 in

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: 10"

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-576verified · printed

burner_type

TWO MANTLE BURNERS NO PILOT BY PASS

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: TWO MANTLE BURNERS NO PILOT BY PASS

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-578verified · printed

receptacle_material

PORCELAIN RECEPTACLE

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: PORCELAIN RECEPTACLE

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-578verified · printed

reinforcing_ring_gauge

No.14 B.&S.

14 gauge

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: No.14 B.&S.

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-578verified · printed

screw_quantity

3 SCREWS No.8-32

3 count

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: 3 SCREWS No.8-32

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-578verified · printed

screw_designation

No.8-32

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

IMG_1296 · Locate on drawing ↗

Drawing notation: No.8-32

Selected source-access normalized region; printed/type-local property. Nominal pipe/casing sizes are not measured outside diameters. Assignment labels establish intended type use only. Source access orientation recorded at image level.

detail-lighting-img1296-559verified · printed

canopy_diameter

6 1/2"

6.5 in

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: 6 1/2"

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-559verified · printed

canopy_parent_relationship

CAST LIKE RING ON No.578

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: CAST LIKE RING ON No.578

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-559verified · printed

canopy_reinforcing_ring_gauge

No.14 B.&S. RING

14 gauge

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: No.14 B.&S. RING

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-559verified · printed

canopy_screw_quantity

3 SCREWS No 8-32

3 count

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: 3 SCREWS No 8-32

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-559verified · printed

canopy_screw_designation

No 8-32

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: No 8-32

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-576verified · printed

backplate_width_segment

3 1/2"

3.5 in

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: 3 1/2"

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-576verified · printed

upper_vertical_dimension_segment

2 1/4"

2.25 in

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: 2 1/4"

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-576verified · printed

lower_vertical_dimension_segment

5 1/2"

5.5 in

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: 5 1/2"

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-578verified · printed

upper_ring_diameter

5 1/4"

5.25 in

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: 5 1/4"

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-578verified · printed

vent_quantity

6 - 1/4" VENTS

6 count

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: 6 - 1/4" VENTS

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

detail-lighting-img1296-578verified · printed

vent_nominal_diameter

6 - 1/4" VENTS

0.25 in

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

IMG_1296 · Locate on drawing ↗

Drawing notation: 6 - 1/4" VENTS

Source-local fixture specimen evidence only. Printed marks are type designations; dimensions describe the indicated component or segment, not installed positions or whole-room geometry. Existing verified data reused; conflicts remain separate.

View all source photographs →