Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1265-detailverified · printed
drawing_title
STAIR DETAILS — TYPICAL FOR STAIRS A B C D E F G & HPartial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
drawing_scale
3" = 1'-0"Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
landing_riser_applicability
TYPICAL SECTION THRU LANDING AND RISERS — FOR STAIRS B D & EPartial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: TYPICAL SECTION THRU LANDING AND RISERS — FOR STAIRS B D & E
Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
two_riser_condition
TYPICAL SECTION OF LANDINGS WHERE TWO RISERS OCCURPartial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
window_condition
TYPICAL SECTION AT WINDOWPartial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · observed
newel_conditions
Typical sections between newel posts at landings / floor levelsPartial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: Typical sections between newel posts at landings / floor levels
Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
wall_rail
WALL HAND RAIL AND BRACKETSPartial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailneeds-review · observed
handwritten_annotation
Red annotation/markup in central newel detail [unreadable]Partial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: Red annotation/markup in central newel detail [unreadable]
Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · observed
prior_report
Existing stair-w228-typical-details-first.md uses IMG_1122; source-dependent sizes not copied to IMG_1265 without crop verificationPartial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: Existing stair-w228-typical-details-first.md uses IMG_1122; source-dependent sizes not copied to IMG_1265 without crop verification
Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailunreviewed · observed
fine_dimensions
Tread/riser, plate/channel/tube, bracket, weld/bolt and rail profiles unresolved at locator sizeNumeric value unresolved
Partial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: Tread/riser, plate/channel/tube, bracket, weld/bolt and rail profiles unresolved at locator size
Partial drawing/detail evidence only; no installed geometry or count established.
closure1011z-w228-ac-window-sectionverified · printed
plate_string_gauge_designation
10 GA PLATE STRING10 gauge
Window-section leader identifies plate string as 10 gauge. No conversion to thickness: gauge standard and metal specification are unresolved.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: 10 GA PLATE STRING
Window-section leader identifies plate string as 10 gauge. No conversion to thickness: gauge standard and metal specification are unresolved.
closure1011z-w228-ac-window-sectionverified · printed
marble_string_thickness
1" THICK MARBLE STRING1 in
Printed leader specifies marble string thickness at window section, separate from plate string. Does not establish total wall/landing thickness or installed length.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: 1" THICK MARBLE STRING
Printed leader specifies marble string thickness at window section, separate from plate string. Does not establish total wall/landing thickness or installed length.
closure1011z-w228-ac-window-sectionverified · printed
channel_nominal_depth
10" CHANNEL10 in
Leader in A/C typical window section identifies nominal channel depth. Distinct from the previously recorded 10-inch channel in the two-riser landing condition; profile series, length and connections remain unknown.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: 10" CHANNEL
Leader in A/C typical window section identifies nominal channel depth. Distinct from the previously recorded 10-inch channel in the two-riser landing condition; profile series, length and connections remain unknown.
detail-w228-staira-c-upper-left-constructionverified · printed
stair_a_detail_applicability
FOR STAIR 'A' BASEMENT TO 2ND FLOORApplicability of this upper-left typical section only; does not assign all W228 generic details to Stair A.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: FOR STAIR 'A' BASEMENT TO 2ND FLOOR
Applicability of this upper-left typical section only; does not assign all W228 generic details to Stair A.
detail-w228-staira-c-upper-left-constructionverified · printed
stair_c_detail_applicability
FOR STAIR 'C' 1ST TO 2ND FLOORApplicability of same upper-left typical section to Stair C.
detail-w228-staira-c-upper-left-constructionverified · printed
wall_material
MARBLE WALLUpper-left wall callout. Storey-specific finish extent still requires Stair A/C placement drawings.
detail-w228-staira-c-upper-left-constructionverified · printed
grout_material
PLASTER GROUTLeader points toward marble/metal interface. Layer thickness and full limits unresolved.
detail-w228-staira-c-upper-left-constructionverified · printed
tread_material
MARBLEExplicit material inside tread/landing slab of upper-left section; exact thickness and extent unresolved.
detail-w228-staira-c-upper-left-constructionverified · printed
inclined_fill_material
TILEPrinted leader toward inclined stair construction; tile type, thickness and exact layer assignment unresolved.
detail-w228-staira-c-upper-left-constructionneeds-review · printed
upper_tread_horizontal_witness
10"10 in
Top horizontal dimension above marble tread zone. Nosing/face endpoint classes require verification.
stair-w228-bde-rail-profile-registerverified · printed
flight_rail_vertical_witness_independent_reading
2'-10"34 in
Independent source read of B/D/E railing witness. Its lower endpoint is above tread surface; this is not certified tread-to-handrail height.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: 2'-10"
Independent source read of B/D/E railing witness. Its lower endpoint is above tread surface; this is not certified tread-to-handrail height.
stair-w228-bde-rail-profile-registerverified · observed
flight_rail_lower_witness_endpoint_class
[lower 2'-10" witness meets inclined railing base/baluster-base pitch line; separate VARIES witness continues downward to safety tread]Classifies drawing relationship only. Exact base-rail member face remains to be confirmed; variable lower offset cannot be discarded.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: [lower 2'-10" witness meets inclined railing base/baluster-base pitch line; separate VARIES witness continues downward to safety tread]
Classifies drawing relationship only. Exact base-rail member face remains to be confirmed; variable lower offset cannot be discarded.
stair-w228-bde-rail-profile-registerunreviewed · observed
flight_rail_upper_witness_endpoint_class
[upper 2'-10" witness extends to top sloping rail profile]Top rail line appears to receive extension; precise outer versus profile reference face still needs fabrication-level check.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: [upper 2'-10" witness extends to top sloping rail profile]
Top rail line appears to receive extension; precise outer versus profile reference face still needs fabrication-level check.
stair-w228-bde-rail-profile-registerunreviewed · derived
flight_tread_to_handrail_height_unresolved
2'-10" + VARIESNumeric value unresolved
Variable offset from tread to railing-base reference is undimensioned. Do not replace with universal34-in or36-in height.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: 2'-10" + VARIES
Variable offset from tread to railing-base reference is undimensioned. Do not replace with universal34-in or36-in height.
stair-w228-bde-rail-profile-registerverified · observed
landing_newel_witness_endpoint_class
[3'-0" witness from top landing tread surface to newel shoulder below cast-iron cap]Landing newel shoulder datum only; cap top is visibly above upper witness. Existing36-in reading retained; this is not a uniform rail-top height.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: [3'-0" witness from top landing tread surface to newel shoulder below cast-iron cap]
Landing newel shoulder datum only; cap top is visibly above upper witness. Existing36-in reading retained; this is not a uniform rail-top height.
stair-w228-bde-rail-profile-registerverified · printed
tubing_callout_target_class
NEWEL - [fraction] STEEL TUBING - 4" SQUARE - CAST IRON CAPVertical callout is explicitly for NEWEL, correcting prior unresolved handrail-versus-newel attribution; small thickness fraction remains uncertified.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: NEWEL - [fraction] STEEL TUBING - 4" SQUARE - CAST IRON CAP
Vertical callout is explicitly for NEWEL, correcting prior unresolved handrail-versus-newel attribution; small thickness fraction remains uncertified.
stair-w228-bde-rail-profile-registerillegible · printed
newel_tubing_wall_thickness_unresolved
NEWEL - [fraction] STEEL TUBINGNumeric value unresolved
No numeric fraction certified; review with clearer companion or dedicated rotated crop.
stair-w228-bde-rail-profile-registerverified · printed
newel_tubing_wall_thickness_resolution
NEWEL — 3/16″ STEEL TUBING — 4″ SQUARE — CAST IRON CAP0.1875 in
Both1122 and1265 native crops read3/16 at NEWEL callout. Wall thickness belongs to square newel tubing; not handrail tubing, bar side or F/G/H centreline halves. No installed member extents/quantities.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: NEWEL — 3/16″ STEEL TUBING — 4″ SQUARE — CAST IRON CAP
Both1122 and1265 native crops read3/16 at NEWEL callout. Wall thickness belongs to square newel tubing; not handrail tubing, bar side or F/G/H centreline halves. No installed member extents/quantities.
Calculated from: stair-companion1013b-img_1265-m029, stair-companion1013b-img_1265-m030
stair-w228-bde-rail-profile-registerverified · printed
newel_body_material
STEEL TUBINGBody material independently normalized from tubing leader; cap material separately recorded, nominal side reused.
Calculated from: stair-endpoint1013d-img_1265-m043, stairbuild1013f-img_1265-m022
stair-w228-bde-rail-profile-registerverified · printed
newel_cap_material
CAST IRON CAPCap material, distinct from steel tubing body and square balusters; complete ornamental cap dimensions remain open.
Calculated from: stair-endpoint1013d-img_1265-m043
stair-w228-bde-rail-profile-registerverified · observed
inclined_guard_lower_witness_reference_face
[2′10″ lower arrow lands on upper drawn edge of inclined base-rail profile]Native crop shows lower34in witness intersecting the upper boundary of bottom rail, above safety-tread plane. Separate vertical VARIES extends to tread top. Source-line classification only; no rail solid, thickness or tread-to-handrail height.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: [2′10″ lower arrow lands on upper drawn edge of inclined base-rail profile]
Native crop shows lower34in witness intersecting the upper boundary of bottom rail, above safety-tread plane. Separate vertical VARIES extends to tread top. Source-line classification only; no rail solid, thickness or tread-to-handrail height.
Calculated from: stair-companion1013b-img_1265-m025, stair-endpoint1013d-img_1265-m041, stair-fine1013e-img_1122-m025
stair-w228-bde-rail-profile-registerverified · observed
inclined_guard_upper_witness_reference_face
[2′10″ upper arrow reaches outer upper line of profiled inclined handrail]Source upper line reference is visible in native crop; round/ornamental end cross-section still lacks fully certified face dimensions. Not universal installed guard height.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: [2′10″ upper arrow reaches outer upper line of profiled inclined handrail]
Source upper line reference is visible in native crop; round/ornamental end cross-section still lacks fully certified face dimensions. Not universal installed guard height.
Calculated from: stair-companion1013b-img_1265-m026
stair-w228-bde-rail-profile-registerverified · printed
inclined_string_profile_middle_face_source_witness
10″10 in
Isolated inclined string section beside B/D/E flight has10in witness along central flat face between moulding transitions. Not overall string depth, flight width or metal gauge; full cap/base offset fractions not certified.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: 10″
Isolated inclined string section beside B/D/E flight has10in witness along central flat face between moulding transitions. Not overall string depth, flight width or metal gauge; full cap/base offset fractions not certified.
stair-w228-bde-rail-profile-registerillegible · printed
inclined_string_profile_cap_and_base_offsets_unresolved
[small offset fractions beside10″ middle face]Numeric value unresolved
Native crop does not confidently certify both offset fractions; no overall profile depth calculated.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: [small offset fractions beside10″ middle face]
Native crop does not confidently certify both offset fractions; no overall profile depth calculated.
stair-w228-bde-rail-profile-registerverified · printed
panelled_riser_component_relationship
PANELLED RISERS / REPLACEABLE SAFETY TREADSSeparate arrows identify vertical panelled risers and removable top safety-tread components. Material/product, thickness, fastening and replacement clearance remain unresolved.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: PANELLED RISERS / REPLACEABLE SAFETY TREADS
Separate arrows identify vertical panelled risers and removable top safety-tread components. Material/product, thickness, fastening and replacement clearance remain unresolved.
Calculated from: w228-intermediate-landing-finish-rule
stair-w228-bde-rail-profile-registerverified · printed
square_bar_nominal_side_w228_bde
⅝″ SQ BARS0.625 in
B/D/E typical rail bar callout only. W225/IMG1116 has separate3/4-in E bar evidence; do not select one for all E floors or replace either source.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: ⅝″ SQ BARS
B/D/E typical rail bar callout only. W225/IMG1116 has separate3/4-in E bar evidence; do not select one for all E floors or replace either source.
stair-w228-bde-rail-profile-registerunreviewed · printed
cross_source_bar_size_applicability_unresolved
W228⅝″ SQ BARS / W225 E indicated first-to-second¾″ square barsDifferent source scopes retained separately pending component and floor applicability; no silent overwrite or installation count.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: W228⅝″ SQ BARS / W225 E indicated first-to-second¾″ square bars
Different source scopes retained separately pending component and floor applicability; no silent overwrite or installation count.
Calculated from: stair-endpoint1013d-img_1265-m038, stairs1012a-1116-m001
Conflicting readings: stairs1012a-1116-m001
stair-w228-bde-rail-profile-registerunreviewed · printed
newel_shoulder_to_rail_attachment_vertical_source_witness
2″2 in
Printed2-in local span near shoulder and rail profile attachment in landing newel elevation. Exact profile face/centre endpoint remains unreviewed; not additional universal guard height.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: 2″
Printed2-in local span near shoulder and rail profile attachment in landing newel elevation. Exact profile face/centre endpoint remains unreviewed; not additional universal guard height.
stair-w228-bde-rail-profile-registerunreviewed · observed
base_rail_profile_and_varies_endpoint_relationship
[inclined base rail has distinct paired profile edges; VARIES vertical leg links its reference region to the safety-tread surface]Refines local profile topology without certifying which base-rail face carries the height extension. Existing34-in/36-in witnesses reused, never promoted to tread-to-rail height.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: [inclined base rail has distinct paired profile edges; VARIES vertical leg links its reference region to the safety-tread surface]
Refines local profile topology without certifying which base-rail face carries the height extension. Existing34-in/36-in witnesses reused, never promoted to tread-to-rail height.
Calculated from: stair-companion1013b-img_1265-m025, stair-companion1013b-img_1265-m027
stair-w228-bde-rail-profile-registerunreviewed · printed
base_rail_to_tread_variable_offset_unresolved
VARIESNumeric value unresolved
Drawing supplies variable-offset notation without numeric value or station. Exact tread/nosing and base-rail face relation remains open; retain as actual-unit numeric null.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: VARIES
Drawing supplies variable-offset notation without numeric value or station. Exact tread/nosing and base-rail face relation remains open; retain as actual-unit numeric null.