Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1236 · Folder 190

Building sections and part elevation of court wall

Sheet W105

Extraction: Reviewed · extraction partial. Full close-photograph overview plus one dimension-chain crop;30court apertures, materials and selected heights; fractional offsets unresolved. Partial timed visual review: Source-local printed/observed section controls, independent local ceiling/roof and finish scopes; no building geometry approval. Partial timed visual review: Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved. Partial timed visual review: Court-wall vertical chain follow-up only. Raw 4032 by 3024 master needs 90 degrees clockwise, yielding 3024 by 4032 upright pixels. Initial raw crop was sideways and missed the intended sill chain; no property attributed to that locator.

Unresolved extraction work
  • Fractional sill/head dimensions
  • Horizontal column-to-opening stations
  • Window widths and sash sheet210
  • Wall/coping thicknesses
  • Left cropped exhaust-louver assembly
  • Court compass assignment
  • Other walls not represented
  • Finished/rough/structural boundary classes and physical source-to-plan registration remain unaccepted.
  • Remaining fine dimensions, all material/finish schedules, notes and historical revisions need regional and companion review.
  • No installed quantity, geometry, as-built state or architectural release is accepted.
  • F8 sill/head fractions, copying thickness and all louver/roof detail extents
  • Accept masonry/frame/sash/clear-edge classification separately; exact horizontal stations unresolved
  • All full widths, type marks and accepted frame geometry
  • Cropped assembly extent, nominal width/height endpoint confirmation, full Sheet210 review
  • Exact dimensions and witness endpoints not fully extracted
  • Companion-detail, revision and floor/room registration unresolved
  • All-region review and modeling acceptance incomplete
  • Small sill/head fractions
  • Horizontal stations and widths
  • Other wall/roof/louver regions and companion details

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

57 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

wall-court-C62-C67illegible · printed

fifth/sixth-floor sill offset

2′3…″ (fractional inch remains unresolved)

Numeric value unresolved

Do not round or derive a sill from the 6′6″ opening height.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2′3…″; fraction not securely resolved

wall-court-C62-C67illegible · printed

seventh-floor regional sill offsets

4′3…″ above lower line; 2′3…″ above south line (fractions unresolved)

Numeric value unresolved

Both seventh-floor references must be retained; the 2′0″ regional step is verified separately.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 4′3…″;2′3…″;fractional inches unresolved

detail-facade-1236-court-sill-chainverified · printed

fifth_floor_reference_to_opening_sill

2′3½″

27.5 in

Lower F5 floor reference line to graphic sill witness of window5/48. Sill/frame/masonry class unresolved.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2′3½″

Lower F5 floor reference line to graphic sill witness of window5/48. Sill/frame/masonry class unresolved.

detail-facade-1236-court-sill-chainverified · printed

fifth_opening_head_to_sixth_floor_reference

2′8½″

32.5 in

Graphic head of F5 window5/48 to next/F6 floor reference. A separate head-to-floor term, not window height.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2′8½″

Graphic head of F5 window5/48 to next/F6 floor reference. A separate head-to-floor term, not window height.

detail-facade-1236-court-sill-chainverified · printed

sixth_floor_reference_to_opening_sill

2′3½″

27.5 in

F6 floor reference line to graphic sill witness of window6/48. Separate literal fraction from F5 despite repeated value.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2′3½″

F6 floor reference line to graphic sill witness of window6/48. Separate literal fraction from F5 despite repeated value.

detail-facade-1236-court-sill-chainverified · printed

sixth_opening_head_to_lower_seventh_floor_reference

2′8½″

32.5 in

Graphic F6 window6/48 head to lower/Main seventh-floor reference. Does not use higher south-end floor datum.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2′8½″

Graphic F6 window6/48 head to lower/Main seventh-floor reference. Does not use higher south-end floor datum.

detail-facade-1236-court-sill-chainverified · printed

lower_main_seventh_floor_reference_to_opening_sill

4′3½″

51.5 in

Lower/Main F7 reference to graphic sill of window7/44. Distinct witness from raised south-end floor to same sill.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 4′3½″

Lower/Main F7 reference to graphic sill of window7/44. Distinct witness from raised south-end floor to same sill.

detail-facade-1236-court-sill-chainverified · printed

raised_south_end_seventh_floor_reference_to_opening_sill

2′3½″

27.5 in

Raised south-end F7 reference to same graphic sill of window7/44. Existing2′0″ step remains independent; no regional flattening.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2′3½″

Raised south-end F7 reference to same graphic sill of window7/44. Existing2′0″ step remains independent; no regional flattening.

detail-facade-1236-court-sill-chainverified · printed

seventh_opening_head_to_eighth_floor_reference

2′8½″

32.5 in

Graphic head of window7/44 to F8 floor reference. Top of this crop excludes remaining F8 head/sill terms.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2′8½″

Graphic head of window7/44 to F8 floor reference. Top of this crop excludes remaining F8 head/sill terms.

detail-facade-1236-court-sill-chainverified · derived

fractional_step_witness_closure

4′3½″ − 2′3½″ = 2′0″

24 in

Independent printed fractions differ by24in, matching existing printed2ft regional step. This is a check of separate source witnesses; it cannot locate the floor transition in plan.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 4′3½″ − 2′3½″ = 2′0″

Independent printed fractions differ by24in, matching existing printed2ft regional step. This is a check of separate source witnesses; it cannot locate the floor transition in plan.

Calculated from: section1013j-court-f7-main-sill, section1013j-court-f7-south-sill, ms-F7-main-madison-step-printed

detail-facade-1236-exhaust-louververified · printed

exhaust-louver-width

EXHAUST LOUVERS 24" x 54"

24 in

Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: EXHAUST LOUVERS 24" x 54"

Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.

detail-facade-1236-exhaust-louververified · printed

exhaust-louver-height

EXHAUST LOUVERS 24" x 54"

54 in

Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: EXHAUST LOUVERS 24" x 54"

Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.

detail-facade-1236-court-sill-chainunreviewed · printed

fifth-floor-sill-fraction-unresolved

2'-3[small fraction unresolved]

Numeric value unresolved

Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2'-3[small fraction unresolved]

Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.

Conflicting readings: ms-court-fractional-sill-F5-unresolved

detail-facade-1236-court-sill-chainunreviewed · printed

seventh-floor-left-sill-fraction-unresolved

4'-3[small fraction unresolved]

Numeric value unresolved

Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 4'-3[small fraction unresolved]

Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved.

Conflicting readings: ms-court-fractional-sill-F7-unresolved

type-court-C62-C67-window-F5-F7unreviewed · printed

repeated_sill_head_fraction_followup

2'-3[small fraction] / 2'-8[small fraction] / 4'-3[small fraction]

Numeric value unresolved

F5/F6 sill and head witnesses and F7 stepped-floor witness now targeted at master resolution, but small stacked denominators remain insecure. Do not use an 11'-6" closure to manufacture a fractional reading. Existing 6'-6" opening heights and 2'-0" regional step reused.

IMG_1236 · sheet-W105 · Locate on drawing ↗

Drawing notation: 2'-3[small fraction] / 2'-8[small fraction] / 4'-3[small fraction]

F5/F6 sill and head witnesses and F7 stepped-floor witness now targeted at master resolution, but small stacked denominators remain insecure. Do not use an 11'-6" closure to manufacture a fractional reading. Existing 6'-6" opening heights and 2'-0" regional step reused.

View all source photographs →