Opening frame material
DOF3 row only; repeated DO notes refer to steel sash. No thickness/profile established.
Drawing notation: DO
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Original sheet identity has not yet been reconciled.
Extraction: Reviewed · extraction partial. Partial: façade opening identities/counts and selected printed datums. Drawing number, registration and opening dimensions still unresolved. Reuse of existing text/registered property data only; no new image review. Main upper wall corners and visible floor datum courses. 69 previously identified Broadway opening instances, individually repicked visible envelopes. Main coping/parapet/cornice/frieze/F3 belt envelopes. Basement dashed windows, sidewalk/finish-grade guide lines, visible boiler reference. Text-first physical-pilot gate 3 audit; existing reviewed plan, elevation and section records reused without reopening an archival image. Page-right 4/11 metric/cardinal conflict audit; Existing B02 visible elevation envelope, master pixels about x1199–1298/y1311–1437; opening mark was not independently decoded from this elevation. Page-right 4/11 metric/cardinal conflict audit; Existing B09 visible envelope, master pixels x2763–2864/y1318–1444; metric alternative only, not a confirmed key match. Page-right 4/11 metric/cardinal conflict audit; Right-end street label fixes right as south/Madison. Partial timed visual review: Text-only prior evidence inventory; catalogue labels are discovery-only and prior verified identity retained. Partial timed visual review: Source-local architectural evidence only; no physical registration, installed quantity or accepted geometry. Existing verified measurements omitted; conflicting locator readings preserved. Partial timed visual review: Bounded target crop inspection; source-local printed/observed evidence only.
Loading the selected drawing…
Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.
Open source image separately ↗Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
F3 row only; repeated DO notes refer to steel sash. No thickness/profile established.
Drawing notation: DO
66.5155 ft · estimated uncertainty ±2 ft
6.272 ft · estimated uncertainty ±2 ft
135.1784 ft · estimated uncertainty ±1.25 ft
127.6237 ft · estimated uncertainty ±1.25 ft
7.5547 ft · estimated uncertainty ±1.75 ft
Numeric value unresolved
Masonry/frame/clear-width distinction not resolved; do not use visible envelope as clear opening.
Circled mark visible, but exact numerator/denominator/type glyph not reliably read in this bounded review.
F3 row only; repeated DO notes refer to steel sash. No thickness/profile established.
Drawing notation: DO
-66.3767 ft · estimated uncertainty ±2 ft
6.245 ft · estimated uncertainty ±2 ft
146.9989 ft · estimated uncertainty ±1.25 ft
139.3891 ft · estimated uncertainty ±1.25 ft
7.6099 ft · estimated uncertainty ±1.75 ft
Numeric value unresolved
Masonry/frame/clear-width distinction not resolved; do not use visible envelope as clear opening.
Circled mark visible, but exact numerator/denominator/type glyph not reliably read in this bounded review.
Material not established by outline or grille name.
-48.4776 ft · estimated uncertainty ±2 ft
6.0595 ft · estimated uncertainty ±2 ft
146.9234 ft · estimated uncertainty ±1.25 ft
139.222 ft · estimated uncertainty ±1.25 ft
7.7014 ft · estimated uncertainty ±1.75 ft
Numeric value unresolved
Masonry/frame/clear-width distinction not resolved; do not use visible envelope as clear opening.
Circled mark visible, but exact numerator/denominator/type glyph not reliably read in this bounded review.
Material not established by outline or grille name.
-34.3236 ft · estimated uncertainty ±2 ft
6.0291 ft · estimated uncertainty ±2 ft
146.8071 ft · estimated uncertainty ±1.25 ft
139.137 ft · estimated uncertainty ±1.25 ft
7.6701 ft · estimated uncertainty ±1.75 ft
Numeric value unresolved
Masonry/frame/clear-width distinction not resolved; do not use visible envelope as clear opening.
Circled mark visible, but exact numerator/denominator/type glyph not reliably read in this bounded review.
Material not established by outline or grille name.
-20.5906 ft · estimated uncertainty ±2 ft
6.0278 ft · estimated uncertainty ±2 ft