Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1228 · Folder 190

Roof Plan

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial text-first sequential locator review using <=1000px JPEG derivative of public/archive/drawings/complete-upright/IMG_1228.webp. Access-image normalized regions before rotation; rotationDegrees is clockwise turn required for primary lettering. Locator coverage does not mean complete regional extraction. No modeling. Partial timed visual review: Sequential 2200px WebP review; additive selected remaining properties only. No geometry acceptance. Partial timed visual review: Selected additional source-local property review; normalized regions reference unrotated access derivative; no metric transform. Partial timed visual review: Full architectural region inventory by existing object/property sources, with explicit pending work. Reused bounding regions do not certify exhaustive visual coverage.

Unresolved extraction work
  • full review of all regions, dimensions, schedules, callouts and notes
  • floor/object registration
  • cropped or faint evidence and companion sheets
  • Remaining dimensions and endpoint classification
  • Materials, schedules and companion details not yet completely reconciled
  • Accepted source registration and geometry checking
  • Closed geometry and finish/rough/structural endpoint classification
  • Complete quantities, schedules, companion details and revision reconciliation
  • Accepted source registration and held-out geometry checks
  • All remaining fine dimensions, notes, callouts, schedules and revision authority need regional review.
  • Accepted finished/rough/structural faces, material extents and closed physical bounds remain unresolved.
  • Source registration, held-out checks, companion applicability and installed quantities remain unaccepted.
  • Remaining cap-roof inset identities, full intake section chain, lower-right roof region and exact layer/roof field applicability are not closed.
  • Screen material species unresolved after MESH note reread; do not infer Monel.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

52 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

upperplan1013h-roof-boardwalk-detailverified · printed

support_bolt_diameter

½″ φ BOLT

0.5 in

Printed boardwalk construction control. Nominal lumber sizes, clear plank gap, width witness, support pitch and bolt designation remain separate; no installed run count or actual outside lumber dimension.

IMG_1228 · Locate on drawing ↗

Drawing notation: ½″ φ BOLT

Printed boardwalk construction control. Nominal lumber sizes, clear plank gap, width witness, support pitch and bolt designation remain separate; no installed run count or actual outside lumber dimension.

upperplan1013h-roof-boardwalk-detailverified · printed

flashing_relationship

FLASH & COUNTER FLASH

Local boardwalk support attachment has flashing/counterflashing; material and thickness not printed in this token.

IMG_1228 · Locate on drawing ↗

Drawing notation: FLASH & COUNTER FLASH

Local boardwalk support attachment has flashing/counterflashing; material and thickness not printed in this token.

upperplan1013h-roof-boardwalk-detailverified · printed

roof_layer_covering

COMP. ROOFING

Roof covering is separately identified in local support section; thickness and applicability to whole field unknown.

IMG_1228 · Locate on drawing ↗

Drawing notation: COMP. ROOFING

Roof covering is separately identified in local support section; thickness and applicability to whole field unknown.

upperplan1013h-roof-boardwalk-detailverified · printed

roof_layer_insulation

INSULATION

Distinct insulation layer at support section; product and thickness unresolved.

IMG_1228 · Locate on drawing ↗

Drawing notation: INSULATION

Distinct insulation layer at support section; product and thickness unresolved.

upperplan1013h-roof-boardwalk-detailverified · printed

roof_layer_slab

ROOF SLAB

Distinct roof slab at support section; structural thickness, concrete specification and underside level unestablished.

IMG_1228 · Locate on drawing ↗

Drawing notation: ROOF SLAB

Distinct roof slab at support section; structural thickness, concrete specification and underside level unestablished.

upperplan1013h-roof-boardwalk-detailunreviewed · printed

roof_layer_insulation_thickness

Unresolved

Numeric value unresolved

No readable thickness token in selected support section; cannot reuse unrelated floor-fill thickness.

IMG_1228 · Locate on drawing ↗

No readable thickness token in selected support section; cannot reuse unrelated floor-fill thickness.

upperplan1013h-roof-boardwalk-detailunreviewed · printed

roof_slab_thickness

Unresolved

Numeric value unresolved

No readable slab-thickness token in selected support section; physical roof gate remains open.

IMG_1228 · Locate on drawing ↗

No readable slab-thickness token in selected support section; physical roof gate remains open.

upperplan1013h-roof-cap-inset-square-img1228verified · printed

gutter_material

COPPER GUTTER AND D.S.

Copper gutter attached to this square inset cap roof. Inset-to-headhouse relationship unresolved.

IMG_1228 · Locate on drawing ↗

Drawing notation: COPPER GUTTER AND D.S.

Copper gutter attached to this square inset cap roof. Inset-to-headhouse relationship unresolved.

upperplan1013h-roof-cap-inset-square-img1228verified · printed

downspout_material

COPPER GUTTER AND D.S.

Copper downspout in same inset annotation; no diameter adopted from another detail.

IMG_1228 · Locate on drawing ↗

Drawing notation: COPPER GUTTER AND D.S.

Copper downspout in same inset annotation; no diameter adopted from another detail.

upperplan1013h-roof-cap-inset-square-img1228verified · printed

covering_material

COMPOSITION ROOF

Printed cap-roof covering, separate from main roof fields.

IMG_1228 · Locate on drawing ↗

Drawing notation: COMPOSITION ROOF

Printed cap-roof covering, separate from main roof fields.

upperplan1013h-roof-cap-inset-square-img1228verified · observed

drainage_direction_depiction

[four arrows and diagonals to cap perimeter]

Observed drainage direction sketch; no numeric pitch or faceted physical surface.

IMG_1228 · Locate on drawing ↗

Drawing notation: [four arrows and diagonals to cap perimeter]

Observed drainage direction sketch; no numeric pitch or faceted physical surface.

upperplan1013h-roof-cap-inset-square-img1228unreviewed · printed

numeric_roof_pitch

Unresolved

Numeric value unresolved

No numerical slope token in selected cap inset; drainage arrows do not establish slope.

IMG_1228 · Locate on drawing ↗

No numerical slope token in selected cap inset; drainage arrows do not establish slope.

View all source photographs →