Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 6 · west
51.256 ft (trace)51.256 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 6 · north
55.329 ft (trace)55.329 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 7 · west
51.293 ft (trace)51.293 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 7 · north
47.226 ft (trace)47.226 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 8 · west
50.876 ft (trace)50.876 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 8 · north
47.229 ft (trace)47.229 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 9 · west
50.917 ft (trace)50.917 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 9 · north
38.07 ft (trace)38.07 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 10 · west
35.046 ft (trace)35.046 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-lobby-west-floor-regionunreviewed · traced
Boundary vertex 10 · north
38.187 ft (trace)38.187 ft · estimated uncertainty ±3.25 ft
Calculated from: f7-lobby-west-floor-region-footprint-trace
f7-door-701-Funreviewed · traced
Opening endpoint 1 · west
-74.906 ft (trace)-74.906 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-701-Funreviewed · traced
Opening endpoint 1 · north
-56.994 ft (trace)-56.994 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-701-Funreviewed · traced
Opening endpoint 2 · west
-73.078 ft (trace)-73.078 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-701-Funreviewed · traced
Opening endpoint 2 · north
-57.011 ft (trace)-57.011 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-701-Funreviewed · derived
Traced opening width
1.827 ft (not a printed door size)1.827 ft · estimated uncertainty ±1 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
Calculated from: f7-door-701-F-jamb-1-west, f7-door-701-F-jamb-1-north, f7-door-701-F-jamb-2-west, f7-door-701-F-jamb-2-north
f7-door-701-Funreviewed · observed
height
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-701-Funreviewed · observed
sill
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-701-Funreviewed · observed
printed-width
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-709-Gunreviewed · traced
Opening endpoint 1 · west
75.326 ft (trace)75.326 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-709-Gunreviewed · traced
Opening endpoint 1 · north
-57.594 ft (trace)-57.594 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-709-Gunreviewed · traced
Opening endpoint 2 · west
77.308 ft (trace)77.308 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-709-Gunreviewed · traced
Opening endpoint 2 · north
-57.613 ft (trace)-57.613 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-709-Gunreviewed · derived
Traced opening width
1.982 ft (not a printed door size)1.982 ft · estimated uncertainty ±1 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
Calculated from: f7-door-709-G-jamb-1-west, f7-door-709-G-jamb-1-north, f7-door-709-G-jamb-2-west, f7-door-709-G-jamb-2-north
f7-door-709-Gunreviewed · observed
height
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-709-Gunreviewed · observed
sill
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-709-Gunreviewed · observed
printed-width
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-703-702unreviewed · traced
Opening endpoint 1 · west
-44.483 ft (trace)-44.483 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-703-702unreviewed · traced
Opening endpoint 1 · north
-66.808 ft (trace)-66.808 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-703-702unreviewed · traced
Opening endpoint 2 · west
-41.804 ft (trace)-41.804 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-703-702unreviewed · traced
Opening endpoint 2 · north
-66.764 ft (trace)-66.764 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-703-702unreviewed · derived
Traced opening width
2.68 ft (not a printed door size)2.68 ft · estimated uncertainty ±1 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
Calculated from: f7-door-703-702-jamb-1-west, f7-door-703-702-jamb-1-north, f7-door-703-702-jamb-2-west, f7-door-703-702-jamb-2-north
f7-door-703-702unreviewed · observed
height
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-703-702unreviewed · observed
sill
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-703-702unreviewed · observed
printed-width
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-702-entryunreviewed · traced
Opening endpoint 1 · west
-45.43 ft (trace)-45.43 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-702-entryunreviewed · traced
Opening endpoint 1 · north
-43.547 ft (trace)-43.547 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-702-entryunreviewed · traced
Opening endpoint 2 · west
-42.971 ft (trace)-42.971 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-702-entryunreviewed · traced
Opening endpoint 2 · north
-43.499 ft (trace)-43.499 ft · estimated uncertainty ±3.25 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
f7-door-702-entryunreviewed · derived
Traced opening width
2.459 ft (not a printed door size)2.459 ft · estimated uncertainty ±1 ft
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.
Calculated from: f7-door-702-entry-jamb-1-west, f7-door-702-entry-jamb-1-north, f7-door-702-entry-jamb-2-west, f7-door-702-entry-jamb-2-north
f7-door-702-entryunreviewed · observed
height
UnresolvedNumeric value unresolved
IMG_1221 · Locate on drawing ↗Drawing notation: Visible door leaves/swing or landing threshold
Visible opening candidate; source-traced jamb points remain provisional.