side perimeter column interval 1
22′7″22.583333 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 22′7″
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Original sheet identity has not yet been reconciled.
Extraction: Reviewed · extraction partial. Coarse room, court, shaft, stair and visible-door topology with independent provisional registration. 31nominal rooms/circulation regions,4shafts (3elevators plus steel stack),8stair envelopes and27selected openings. Seventh-floor outer trace reused only as a parent of the analytical registration curtain. Reused the provisional level-7 Stair E plan envelope and independently read DOWN 22 / UP 20 labels as cross-floor diagnostic inputs. Existing seventh-floor plan room-number evidence reused for cross-source identity correlation. Bounded W-235 to seventh-floor-plan registration gate; component identities remain valid while all source-to-building placements are withheld. Partial timed visual review: Existing appeals audit reused; no image reopened and no duplicate platform records. Partial timed visual review: Sequential full derivative and targeted Court717/716 crop review. Additive source-local relationship verification; existing room dimensions, traced polygons and printed levels are retained without duplication. Geographic directions derive from IMG_1222 compass. No accepted geometry changed. Partial timed visual review: Additional source-local room identity and dimension endpoint review only; no geometry acceptance. Partial timed visual review: Text-only reuse checkpoint; no image reopened. Prior evidence and unresolved work retained. Partial timed visual review: Seventh-floor F/G terminal host sides and west regional short-flight direction. Upright master is raw rotated90° clockwise; access file already upright. Partial timed visual review: Selected source questions and verified prior property crosswalk only; no exhaustive region or source completion claimed. Partial timed visual review: Full architectural region inventory by existing object/property sources, with explicit pending work. Reused bounding regions do not certify exhaustive visual coverage.
Hide coordinated geometry overlay →
Registration: provisional · 4 independent checks · maximum residual 1.312 ft.
Loading the selected drawing…
Scroll or pinch to inspect this drawing. Blue: printed controls. Gold: provisional geometry. Pink: held-out check residuals. An overlay is a comparison, not certification. Archival drawing photograph · Oregon Historical Society research collections.
Open source image separately ↗Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
22.583333 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 22′7″
14 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 14′0″
14 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 14′0″
14 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 14′0″
14 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 14′0″
14 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 14′0″
14 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 14′0″
14 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 14′0″
14 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 14′0″
22.583333 ft
South-to-north order along side; end bays22′7″ and eight14′ intermediate bays.
Drawing notation: 22′7″
157.166667 ft
Drawing notation: 157′2″ (sum of printed bay chain)
Calculated from: f7-side-column-bay-01, f7-side-column-bay-02, f7-side-column-bay-03, f7-side-column-bay-04, f7-side-column-bay-05, f7-side-column-bay-06, f7-side-column-bay-07, f7-side-column-bay-08, f7-side-column-bay-09, f7-side-column-bay-10
1.833333 ft
Endpoint offset, not wall thickness. Together with two offsets the157′2″ column chain closes to160′10″.
Drawing notation: 1′10″
171.75 ft
Printed within Court717; corroborated by Main-region section control. Local dais excluded.
Drawing notation: FIN.FL. EL.171.75
173.75 ft
Printed in south room707/corridor region; corroborated by section's Madison label.
Drawing notation: FIN.FL. EL.173.75
Numeric value unresolved
Last digit not securely read. Apparent173.86 remains a candidate, not an accepted numeric value or the Madison173.75 regional floor.
Drawing notation: FIN.FL. EL.173.8[?]
12 ft
Between the indicated lobby boundary lines; local projections and corridor widening remain.
Drawing notation: 12′0″
20 count
Count only; actual riser height, run and landing geometry need the stair detail.
Drawing notation: DOWN20R
20 count
Count only; actual riser height, run and landing geometry need the stair detail.
Drawing notation: DOWN20R
22 count
Count only; actual riser height, run and landing geometry need the stair detail.
Drawing notation: DOWN22R
20 count
Count only; actual riser height, run and landing geometry need the stair detail.
Drawing notation: UP20R
22 count
Count only; actual riser height, run and landing geometry need the stair detail.
Drawing notation: DOWN22R
22 count
Count only; actual riser height, run and landing geometry need the stair detail.
Drawing notation: DOWN22R
Does not establish penthouse landing elevation.
Drawing notation: TO PENT HOUSE
Drawing notation: SEE SHEETS240,241
Drawing notation: RUBBER TILE FL.
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 701
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 703
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 702
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 704
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 705
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 706
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 707
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 708
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 709
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 719
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 718
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 721
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 720
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 711
Room number separate from column/window marks; footprint geometry remains traced.
Drawing notation: 712