Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1211 · Folder 190

Third-floor office plan

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial: Third floor plan boundaries, room identities, opening candidates and printed control chains. Third-floor outer trace reused only as a parent of the analytical registration curtain. Confirmed Stair D identity, source handedness, third-floor elevation title, and candidate C68/C82-to-perimeter alignments. Existing third-floor door topology reused only. Reused the provisional level-3 Stair E plan envelope as one input to a cross-floor median diagnostic envelope. Partial timed visual review: Bounded text-first follow-up; ten sequential inspections total across nine derivatives including one W-6 same-source core crop. No accepted physical geometry. Existing verified readings omitted. IMG_1209 uses prior closeout text only. Partial timed visual review: Prior verified extraction reused without duplication; selected new properties only. No full-coverage or physical geometry claim. Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: Third-floor source-local Men's339/adjacent janitor and service annotations. Raw0; access WebP's270-degree orientation not used. Partial timed visual review: Text reuse only: floors-2-3 topology records B/D/E only on third floor and explains access WebP rotation 270° from upright raw master. No whole plan reopened.

Hide coordinated geometry overlay →
Registration: provisional · 4 independent checks · maximum residual 0.567 ft.

Unresolved extraction work
  • Printed sheet number
  • Small anteroom and janitor subdivisions
  • Complete door and finish schedules
  • Room ceiling heights
  • Precise stair openings and landing levels
  • Mail-chute and small service penetrations
  • Window instances
  • All wall thicknesses
  • Court roof relationship below and open-to-sky limits
  • No A/C continuation inferred above second floor
  • Exact outside wall face, wall thickness, openings and local facade projections
  • Exact C68/C82 station transfer
  • Local line/face interpretation
  • Third-floor sheet number
  • Complete third-floor architectural extraction
  • No new third-floor geometry extraction.
  • Accepted wall faces
  • Exact stair opening
  • Held-out registration checks
  • All unreviewed local dimensions, exact faces/jambs, room applicability, schedules and companion details remain pending; no full-image extraction claim.
  • Full room/opening/fixture inventory and property extraction
  • Exact witness endpoints, wall faces and closed polygons
  • Companion details, schedules and revision authority
  • Installed quantities, materials and accepted building registration
  • Exact finished/rough/structural/clear face classification and closed boundaries
  • Complete local dimension, door/window/type/detail inventory
  • Applicable companion construction, finish exceptions and chronology
  • Checked physical registration and installed quantities
  • Men's339 east-side symbols/cubicles, fine fixture keys and complete source-to-plumbing crosswalk
  • Accepted source-to-building transform and like-for-like finished/rough/structural face classification
  • Exact closed slab opening, landing perimeter and headroom
  • Construction/rail/nosing detail and revision/as-built reconciliation
  • All remaining unreviewed regions, notes, schedules and companion details
  • Each physical wall/room/opening still needs classified finish/rough/structural faces, closed boundaries, build-up, levels, installed quantity and checked building registration; source glyph closure does not supply these.
  • Exact finished/rough/structural/clear endpoint classes, closed boundaries and physical dimensions remain unresolved.
  • Installed quantities, construction build-up, fixture/material schedules, original/revision authority and companion applicability remain unresolved.
  • Source-to-building registration, datum continuity, independent checks and architectural acceptance remain unaccepted.
  • All remaining unreviewed notes, regions, callouts and schedules require further review.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Blue: printed controls. Gold: provisional geometry. Pink: held-out check residuals. An overlay is a comparison, not certification. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

1115 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

f3-stair-dverified · printed

third_floor_original_finish_elevation

FIN. FL. ELEV. 125.75

125.75 ft

Drawing datum, not a claim about sea-level datum. No local stair-floor step is read.

IMG_1211 · Locate on drawing ↗

Drawing notation: THIRD FLOOR PLAN / FIN. FL. ELEV.125.75

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Read at the plan title in the overview. Corroborates frame-third-floor-schedule-finish and ms-frame-third-floor-schedule-finish-printed.

f3-stair-dverified · derived

third_floor_finish_above_first_floor_zero

125.75 − 93.25 = 32.5 ft

32.5 ft

IMG_1211 · Locate on drawing ↗

Drawing notation: FIN. FL. ELEV.125.75

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference.

IMG_1314 · sheet-W400 · Locate on drawing ↗

Drawing notation: FLOOR ELEVATION 93.25

Reused existing verified frame-first-floor-finish record; image not reopened.

Calculated from: f3-stair-d-placement-third-floor-datum, frame-first-floor-finish

column-82unreviewed · observed

observed_alignment_with_main_perimeter_column94

C82 appears on the C94 transverse station

Candidate alignment, not an accepted equality of canonical X coordinates.

IMG_1211 · Locate on drawing ↗

Drawing notation: 82 / 94

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Support symbols are visually aligned through the office partition. No independent numeric offset or securely identified continuous centerline witness was verified.

column-82unreviewed · observed

observed_alignment_with_broadway_perimeter_column84

C82 appears in the C83–C84 corridor-side row

Candidate alignment, not an accepted equality of canonical Z coordinates.

IMG_1211 · Locate on drawing ↗

Drawing notation: 82 / 83 / 84

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. The wall and structural-rod graphics overlap the row; a verified column-center witness line or dimension chain is still needed.

f3-stair-dunreviewed · observed

exact_horizontal_offset_wall_face

Unresolved

Determine whether the 1′4″ witness terminates at the finished inner boundary used by the prototype.

IMG_1114 · sheet-W224 · Locate on drawing ↗

Determine whether the 1′4″ witness terminates at the finished inner boundary used by the prototype.

IMG_1211 · Locate on drawing ↗

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Determine whether the 1′4″ witness terminates at the finished inner boundary used by the prototype.

f3-stair-dunreviewed · observed

exact_north_offset_wall_face

Unresolved

Determine which lower wall line the 9′0″ ordinate references, including any wall/finish thickness.

IMG_1114 · sheet-W224 · Locate on drawing ↗

Determine which lower wall line the 9′0″ ordinate references, including any wall/finish thickness.

IMG_1211 · Locate on drawing ↗

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Determine which lower wall line the 9′0″ ordinate references, including any wall/finish thickness.

column-82unreviewed · observed

accepted_third_floor_world_x

Unresolved

Numeric value unresolved

Existing interior-column coordinates are foundation traces; candidate C94 alignment not accepted.

IMG_1114 · sheet-W224 · Locate on drawing ↗

Existing interior-column coordinates are foundation traces; candidate C94 alignment not accepted.

IMG_1211 · Locate on drawing ↗

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Existing interior-column coordinates are foundation traces; candidate C94 alignment not accepted.

column-82unreviewed · observed

accepted_third_floor_world_z

Unresolved

Numeric value unresolved

Existing interior-column coordinates are foundation traces; candidate C84 alignment not accepted.

IMG_1114 · sheet-W224 · Locate on drawing ↗

Existing interior-column coordinates are foundation traces; candidate C84 alignment not accepted.

IMG_1211 · Locate on drawing ↗

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Existing interior-column coordinates are foundation traces; candidate C84 alignment not accepted.

column-68unreviewed · observed

accepted_third_floor_world_x

Unresolved

Numeric value unresolved

Common W224 axis with C82 is known but its absolute X is not yet established.

IMG_1114 · sheet-W224 · Locate on drawing ↗

Common W224 axis with C82 is known but its absolute X is not yet established.

IMG_1211 · Locate on drawing ↗

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Common W224 axis with C82 is known but its absolute X is not yet established.

f3-stair-dunreviewed · observed

accepted_type_origin_world_x

Unresolved

Numeric value unresolved

Requires verified interior support station and exact wall-face endpoint.

IMG_1114 · sheet-W224 · Locate on drawing ↗

Requires verified interior support station and exact wall-face endpoint.

IMG_1211 · Locate on drawing ↗

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Requires verified interior support station and exact wall-face endpoint.

f3-stair-dunreviewed · observed

accepted_type_origin_world_z

Unresolved

Numeric value unresolved

Requires verified C82 station and exact 9′0″ wall-reference endpoint.

IMG_1114 · sheet-W224 · Locate on drawing ↗

Requires verified C82 station and exact 9′0″ wall-reference endpoint.

IMG_1211 · Locate on drawing ↗

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Requires verified C82 station and exact 9′0″ wall-reference endpoint.

f3-stair-dunreviewed · observed

accepted_door_jamb_world_station

Unresolved

Numeric value unresolved

Door is a handedness locator; precise jamb/host offsets not extracted.

IMG_1114 · sheet-W224 · Locate on drawing ↗

Door is a handedness locator; precise jamb/host offsets not extracted.

IMG_1211 · Locate on drawing ↗

Raw master upright; rotate the stored 1650×2200 access WebP 90° clockwise to match this reference. Door is a handedness locator; precise jamb/host offsets not extracted.

f3-door-stair-dverified · observed

candidate_host_boundary

Right-hand entry partition of Stair D; local +u / canonical west side

Relational host only. New analytic host identity has no accepted endpoints or thickness of its finished assembly.

IMG_1211 · Locate on drawing ↗

Drawing notation: Visible core threshold or landing door

Reused existing third-floor topology observation; this source was not reopened in the present pass.

stair-e-upper-diagnostic-envelopeunreviewed · calculated

Median west enclosure face

X = -33.275 ft (median provisional trace)

-33.275 ft

Median of the minimum X extents for levels 2, 3, 5, 6 and 7; exact wall face is not accepted.

IMG_1211 · Locate on drawing ↗

Drawing notation: STAIR E

IMG_1221 · Locate on drawing ↗

Drawing notation: STAIR E

Calculated from: f2-stair-e-vertex-1-west, f3-stair-e-vertex-1-west, f5-stair-e-vertex-1-west, f6-stair-e-vertex-1-west, f7-stair-e-vertex-1-west

stair-e-upper-diagnostic-envelopeunreviewed · calculated

Median east enclosure face

X = -24.115 ft (median provisional trace)

-24.115 ft

Median of the maximum X extents for levels 2, 3, 5, 6 and 7; exact wall face is not accepted.

IMG_1211 · Locate on drawing ↗

Drawing notation: STAIR E

IMG_1221 · Locate on drawing ↗

Drawing notation: STAIR E

Calculated from: f2-stair-e-vertex-3-west, f3-stair-e-vertex-3-west, f5-stair-e-vertex-3-west, f6-stair-e-vertex-3-west, f7-stair-e-vertex-3-west

stair-e-upper-diagnostic-envelopeunreviewed · calculated

Median south enclosure face

Z = -71.628 ft (median provisional trace)

-71.628 ft

Median of the minimum Z extents for levels 2, 3, 5, 6 and 7; exact wall face is not accepted.

IMG_1211 · Locate on drawing ↗

Drawing notation: STAIR E

IMG_1221 · Locate on drawing ↗

Drawing notation: STAIR E

Calculated from: f2-stair-e-vertex-1-north, f3-stair-e-vertex-1-north, f5-stair-e-vertex-1-north, f6-stair-e-vertex-1-north, f7-stair-e-vertex-1-north

stair-e-upper-diagnostic-envelopeunreviewed · calculated

Median north enclosure face

Z = -54.971 ft (median provisional trace)

-54.971 ft

Median of the maximum Z extents for levels 2, 3, 5, 6 and 7; exact wall face is not accepted.

IMG_1211 · Locate on drawing ↗

Drawing notation: STAIR E

IMG_1221 · Locate on drawing ↗

Drawing notation: STAIR E

Calculated from: f2-stair-e-vertex-3-north, f3-stair-e-vertex-3-north, f5-stair-e-vertex-3-north, f6-stair-e-vertex-3-north, f7-stair-e-vertex-3-north

stair-e-upper-diagnostic-envelopeunreviewed · calculated

Diagnostic envelope width

9.160 ft (calculated)

9.16 ft

Difference of median X extents; not an accepted clear width.

IMG_1211 · Locate on drawing ↗

Drawing notation: STAIR E

IMG_1221 · Locate on drawing ↗

Drawing notation: STAIR E

Calculated from: stair-e-upper-diagnostic-min-x, stair-e-upper-diagnostic-max-x

stair-e-upper-diagnostic-envelopeunreviewed · calculated

Diagnostic envelope depth

16.657 ft (calculated)

16.657 ft

Difference of median Z extents; not an accepted clear dimension.

IMG_1211 · Locate on drawing ↗

Drawing notation: STAIR E

IMG_1221 · Locate on drawing ↗

Drawing notation: STAIR E

Calculated from: stair-e-upper-diagnostic-min-z, stair-e-upper-diagnostic-max-z

detail1010-img1211-orientationverified · observed

reading_rotation

Reading requires 90 degrees clockwise from access raster

90 deg

THIRD FLOOR PLAN baseline and office labels upright after clockwise 90 degrees. Source coordinates remain pre-rotation. Title-block sheet number still not securely readable in this exposure.

IMG_1211 · Locate on drawing ↗

Drawing notation: Reading requires 90 degrees clockwise from access raster

THIRD FLOOR PLAN baseline and office labels upright after clockwise 90 degrees. Source coordinates remain pre-rotation. Title-block sheet number still not securely readable in this exposure.

f3-room-339verified · printed

local_finish_mark

MENS TOILET / FIN. NO.4

4 finish-mark

Finish mark tied to printed Men's339 region; material scope still controlled by W4 exceptions. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: MENS TOILET / FIN. NO.4

Finish mark tied to printed Men's339 region; material scope still controlled by W4 exceptions. Source-local extraction only; no accepted physical geometry, installation count or world transform.

f3-room-janitor-eastverified · printed

local_finish_mark

JAN. / FIN. NO.6

6 finish-mark

Adjacent Stair B janitor identity reused; do not invent a printed room number. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: JAN. / FIN. NO.6

Adjacent Stair B janitor identity reused; do not invent a printed room number. Source-local extraction only; no accepted physical geometry, installation count or world transform.

middleplan1013h-f3-janitor-east-drawn-basinverified · observed

drawn_symbol_identity

[one rectangular basin-like glyph inside JAN.]

One individual drawing glyph; sanitary/slop-sink type remains unclassified. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: [one rectangular basin-like glyph inside JAN.]

One individual drawing glyph; sanitary/slop-sink type remains unclassified. Source-local extraction only; no accepted physical geometry, installation count or world transform.

middleplan1013h-f3-339-north-row-glyph-1verified · observed

drawn_station_identity

[oval within rectangular frame]

Individual page-left-to-right station in bounded north row; not classified as a lavatory and not an installed count. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: [oval within rectangular frame]

Individual page-left-to-right station in bounded north row; not classified as a lavatory and not an installed count. Source-local extraction only; no accepted physical geometry, installation count or world transform.

middleplan1013h-f3-339-north-row-glyph-2verified · observed

drawn_station_identity

[oval within rectangular frame]

Individual page-left-to-right station in bounded north row; not classified as a lavatory and not an installed count. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: [oval within rectangular frame]

Individual page-left-to-right station in bounded north row; not classified as a lavatory and not an installed count. Source-local extraction only; no accepted physical geometry, installation count or world transform.

middleplan1013h-f3-339-north-row-glyph-3verified · observed

drawn_station_identity

[oval within rectangular frame]

Individual page-left-to-right station in bounded north row; not classified as a lavatory and not an installed count. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: [oval within rectangular frame]

Individual page-left-to-right station in bounded north row; not classified as a lavatory and not an installed count. Source-local extraction only; no accepted physical geometry, installation count or world transform.

middleplan1013h-f3-339-north-row-glyph-4verified · observed

drawn_station_identity

[oval within rectangular frame]

Individual page-left-to-right station in bounded north row; not classified as a lavatory and not an installed count. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: [oval within rectangular frame]

Individual page-left-to-right station in bounded north row; not classified as a lavatory and not an installed count. Source-local extraction only; no accepted physical geometry, installation count or world transform.

middleplan1013h-f3-corridor-drinking-fountainverified · printed

printed_service_identity

DRINKING FOUNTAIN

Leader at corridor side below Men's339 boundary; no equipment type or location transform. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: DRINKING FOUNTAIN

Leader at corridor side below Men's339 boundary; no equipment type or location transform. Source-local extraction only; no accepted physical geometry, installation count or world transform.

middleplan1013h-f3-corridor-directory-boardverified · printed

printed_service_identity

DIRECTORY BOARD

At Main corridor wall opposite Men's339/Stair B; exact board extents/material remain pending. Source-local extraction only; no accepted physical geometry, installation count or world transform.

IMG_1211 · Locate on drawing ↗

Drawing notation: DIRECTORY BOARD

At Main corridor wall opposite Men's339/Stair B; exact board extents/material remain pending. Source-local extraction only; no accepted physical geometry, installation count or world transform.