printed ceiling height
CEILING HEIGHT 17′-0″17 ft
Drawing notation: CEILING HEIGHT 17′-0″
Read with the superintendent-of-mails label in the Broadway-edge crop and at the top of the west-core crop. Approximate locator, not geometry.
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Sheet W3
Extraction: Reviewed · extraction partial. Initial control subset: two exterior overall spans, two column-bay chains with end offsets and arithmetic closure, named spaces, three elevator/stair identities, selected heights and scale-pit dimensions. Provisional registration; coarse footprint trace of named rooms, three elevators, stairs A/C/E, Registry storage stair, loading recess, platform, scale pit and visible door relationships. Partial W3 first-floor core host-boundary and landing audit. Main foyer, immediately adjacent Public Lobby screen row, and opposite Main Street door row only Public-lobby furniture band reviewed for printed DESK symbols, count, relative position, orientation and room containment. Four candidate centers were picked and transformed through the existing provisional registration. Reused verified W3 public-lobby DESK count, room containment, horizontal-axis alignment, east-west long axes and provisional registered centers; no drawing reopened. Bounded W218 plate type and W3 plan-candidate gate; not an installed desk placement. Independent W3 confirmation of Q–Y identities, order, host wall, terminal anchors and handedness. Bounded first-floor elevator audit: FIRST FLOOR PLAN. Bounded first-floor elevator audit: FIRST FLOOR PLAN. Bounded first-floor elevator audit: FIRST FLOOR PLAN. Column identities, first-floor elevator contexts and terminal Main dimension-chain controls only. Elevator detail-to-W3 physical-placement gate: FIRST FLOOR PLAN. Partial entrance-registration review: The prior W3 trace is retained as a provisional entrance-center witness with 2-foot uncertainty. Its traced 4.602-foot length is not used as the finished or operating width. First-floor enclosed outer trace reused only as a parent of the analytical first-story registration curtain. Reuse of existing text/registered property data only; no new image review. Named PUBLIC LOBBY and printed ceiling-height reading. Normalized from an existing text re-audit; this import did not reopen the source image. Partial W3 review: Bay P wall endpoints, label/handedness and independent doorway-center check. Main entrance stair plan only: centerline, upper run endpoint, lower run endpoint, rear landing reference and lower outside-edge width witnesses. Reused registered Main entrance stair centerline, run axis, and endpoints for rail-axis placement. prior text package reused; image not reopened; bounded source review. Center entrance bronze-leaf physical placement gate; one IMG_1298 region checked against prior entrance packages. Center entrance bronze-leaf physical placement gate; one IMG_1298 region checked against prior entrance packages. Elevator-front bounded gate: Elevator 1 entrance center and orientation diagnostic; 2 ft trace uncertainty. Elevator-front bounded gate: Elevator 2 Bay P analytical station; 2 ft trace uncertainty. W3 Main foyer/public lobby screen physical-polygon gate; source group review remains partial. W3 Main foyer/public lobby screen physical-polygon gate; source group review remains partial. W3 Main foyer/public lobby screen physical-polygon gate; source group review remains partial. Elevator No. 1 first-floor cross-sheet physical placement gate; one-axis controls only. Elevator No. 1 first-floor cross-sheet physical placement gate; one-axis controls only. Public lobby W-214/W-4 marble finish-floor gate; typical-bay and room-boundary review partial. Public lobby W-214/W-4 marble finish-floor gate; typical-bay and room-boundary review partial. Public lobby W-214/W-4 marble finish-floor gate; typical-bay and room-boundary review partial. Public lobby W-214/W-4 marble finish-floor gate; typical-bay and room-boundary review partial. W3 first-floor finish note MAIN ENTRANCE FOYER; material identities only. W3 first-floor finish note MAIN POST OFFICE LOBBY; material identities only. W3 first-floor finish note BROADWAY ENTRANCE FOYER; material identities only. W3 first-floor finish note MAIN STAIRS 'A' AND 'C' - 1ST TO 2ND FLOOR; material identities only. W3 first-floor finish note SUPT. OF MAILS; material identities only. W3 first-floor finish note REGISTRY - C.O.D. POSTAL SAVINGS - M.O. AND STAMPS; material identities only. W3 first-floor finish note VAULTS; material identities only. W3 first-floor finish note POST OFFICE WORK ROOM; material identities only. W3 first-floor finish note MAILING VESTIBULE; material identities only. W3 first-floor finish note MAILING PLATFORM AND TRUCK ENTRANCE; material identities only. W3 first-floor finish note ELEVATOR HALL NO. 3; material identities only. W3 first-floor finish note TOILET ROOMS; material identities only. W3 first-floor finish note STAIR HALL 'E'; material identities only. W3 millwork finish schedule; named exceptions and cross-floor default rules transcribed. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Conditional Q-Y central-axis/printed-chain comparison against held-out W3 trace. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Main/foyer-lobby Bay U screen physical-segment gate; no finite solid authorized. Stair A first-floor flight/landing/slab-cut physical gate; no solid authorized. Stair A first-floor flight/landing/slab-cut physical gate; no solid authorized. Stair A first-floor flight/landing/slab-cut physical gate; no solid authorized. Stair A first-floor flight/landing/slab-cut physical gate; no solid authorized. Stair A first-floor flight/landing/slab-cut physical gate; no solid authorized. Main exterior center framed-entrance physical gate; no finite frame or host-wall cut authorized. Main exterior center framed-entrance physical gate; no finite frame or host-wall cut authorized. Main exterior center framed-entrance physical gate; no finite frame or host-wall cut authorized. Main exterior center framed-entrance physical gate; no finite frame or host-wall cut authorized. Main exterior center framed-entrance physical gate; no finite frame or host-wall cut authorized. Main exterior center framed-entrance physical gate; no finite frame or host-wall cut authorized. W214 P5/P6 ceiling-panel/light installation gate; physical fixture position unresolved. W214 P5/P6 ceiling-panel/light installation gate; physical fixture position unresolved. W214 P5/P6 ceiling-panel/light installation gate; physical fixture position unresolved. Partial timed visual review: Additive bounded follow-up; coordinates normalized to unrotated access raster. Original plan/topology records retained. No model acceptance or complete-sheet claim. Partial timed visual review: undefined Partial timed visual review: Source-local partial review; no physical coordinates accepted. Partial timed visual review: undefined Partial timed visual review: First-floor C wrapper / Elevator2 interface; prior count/flight-chain evidence retained.
Show coordinated geometry overlay →
Registration: provisional · 4 independent checks · maximum residual 0.985 ft.
Loading the selected drawing…
Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.
Open source image separately ↗Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
17 ft
Drawing notation: CEILING HEIGHT 17′-0″
Read with the superintendent-of-mails label in the Broadway-edge crop and at the top of the west-core crop. Approximate locator, not geometry.
93.25 ft
Drawing notation: FIN. FL. ELEV. 93.25
Drawing datum only. Independently corroborated by first-floor-finish in datums-frame.json; external vertical benchmark is unresolved.
161.666667 ft
Drawing notation: 161′-8″
Overall dimension witness lines at the Main facade terminals. Exact masonry face/finish and projecting steps must be registered before using this as a polygon.
161.666667 ft
Drawing notation: 161′-8″
Vertical dimension in upright master. Read after rotating crop +90° clockwise. Exact masonry face/finish endpoint registration remains outstanding.
15.583333 ft
Drawing notation: 15′-7″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
14 ft
Drawing notation: 14′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
15 ft
Drawing notation: 15′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
13 ft
Drawing notation: 13′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
14 ft
Drawing notation: 14′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
14 ft
Drawing notation: 14′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
14 ft
Drawing notation: 14′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
13 ft
Drawing notation: 13′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
15 ft
Drawing notation: 15′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
14 ft
Drawing notation: 14′-0″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
15.583333 ft
Drawing notation: 15′-7″
Main dimension chain ordered page left→right, geographic east/Sixth→west/Broadway. Not a room-width measurement. Cross-sheet column correspondence still requires registration.
2.25 ft
Drawing notation: 2′-3″
Short printed terminal offset between the outer column-chain witness and overall witness. It is not a wall thickness.
2.25 ft
Drawing notation: 2′-3″
Short printed terminal offset between the outer column-chain witness and overall witness. It is not a wall thickness.
22.583333 ft
Drawing notation: 22′-7″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
14 ft
Drawing notation: 14′-0″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
14 ft
Drawing notation: 14′-0″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
14 ft
Drawing notation: 14′-0″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
14 ft
Drawing notation: 14′-0″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
14 ft
Drawing notation: 14′-0″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
14 ft
Drawing notation: 14′-0″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
14 ft
Drawing notation: 14′-0″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
14 ft
Drawing notation: 14′-0″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
22.583333 ft
Drawing notation: 22′-7″
Broadway dimension chain ordered north/Main→south/Madison, bottom→top on upright master. Read from +90°-rotated crop; locator is broad. Not a room-width measurement.
2.25 ft
Drawing notation: 2′-3″
Short printed terminal offset. Not a wall thickness.
2.25 ft
Drawing notation: 2′-3″
Short printed terminal offset. Not a wall thickness.
157.166667 ft
Drawing notation: 15′7″ + 14′ + 15′ + 13′ + 14′ + 14′ + 14′ + 13′ + 15′ + 14′ + 15′7″
Arithmetic only; agrees with W400's 157′2″ outer-column-centerline width. Does not establish a photo registration.
Calculated from: f1-control-main-bay-01, f1-control-main-bay-02, f1-control-main-bay-03, f1-control-main-bay-04, f1-control-main-bay-05, f1-control-main-bay-06, f1-control-main-bay-07, f1-control-main-bay-08, f1-control-main-bay-09, f1-control-main-bay-10, f1-control-main-bay-11
157.166667 ft
Drawing notation: 22′7″ + 8 × 14′0″ + 22′7″
Arithmetic only; agrees with W400's 157′2″ outer-column-centerline depth.
Calculated from: f1-control-broadway-bay-01, f1-control-broadway-bay-02, f1-control-broadway-bay-03, f1-control-broadway-bay-04, f1-control-broadway-bay-05, f1-control-broadway-bay-06, f1-control-broadway-bay-07, f1-control-broadway-bay-08, f1-control-broadway-bay-09, f1-control-broadway-bay-10
161.666667 ft
Drawing notation: 157′2″ + 2′3″ + 2′3″ = 161′8″
Zero arithmetic residual against f1-control-main-overall. Orthorectification and physical wall-face identification remain unresolved.
Calculated from: f1-control-main-chain-sum, f1-control-main-east-offset, f1-control-main-west-offset
161.666667 ft
Drawing notation: 157′2″ + 2′3″ + 2′3″ = 161′8″
Zero arithmetic residual against f1-control-broadway-overall. Not a completed exterior outline.
Calculated from: f1-control-broadway-chain-sum, f1-control-broadway-north-offset, f1-control-broadway-south-offset
17 ft
Drawing notation: CEILING HEIGHT 17′-0″
Printed ceiling height applies to this named area; it does not prove a uniform ceiling throughout every recess or adjoining space.
18 ft
Drawing notation: CEILING HEIGHT 18′-0″
Printed ceiling height applies to this named area; it does not prove a uniform ceiling throughout every recess or adjoining space.
18 ft
Drawing notation: CEILING HEIGHT 18′-0″
Printed ceiling height applies to this named area; it does not prove a uniform ceiling throughout every recess or adjoining space.
18.75 ft
Drawing notation: CEILING HEIGHT 18′-9″
Printed ceiling height applies to this named area; it does not prove a uniform ceiling throughout every recess or adjoining space.
18.416667 ft
Drawing notation: CEILING HEIGHT 18′-5″
Printed ceiling height applies to this named area; it does not prove a uniform ceiling throughout every recess or adjoining space.
Numeric value unresolved
Drawing notation: CEILING HEIGHT 18′-[?]″
Final inches digit not confidently transcribed; do not substitute a plausible height.
Numeric value unresolved
Drawing notation: CEILING HEIGHT 10′-[?]″
Final inches digit not confidently transcribed; do not substitute a plausible height.