Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1200 · Folder 190

Basement plan—Post Office storage and court exhibits

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Independent registration, named and numbered room/core locations, coarse boundary traces and selected visible door relationships. Partial timed visual review: Additive bounded follow-up; coordinates normalized to unrotated access raster. Original plan/topology records retained. No model acceptance or complete-sheet claim. Partial timed visual review: undefined Partial timed visual review: Source-local partial review; no physical coordinates accepted. Partial timed visual review: undefined Partial timed visual review: Basement Stair C / Elevator 2 wrapper and selected local witness, not a complete basement extraction.

Hide coordinated geometry overlay →
Registration: provisional · 6 independent checks · maximum residual 1.621 ft.

Unresolved extraction work
  • All dimensions and notes
  • All wall thicknesses/materials
  • Door/window schedules
  • Physical slab edges and openings
  • Every room clear dimension
  • All stair/shaft vertical details
  • Regional levels and complete cross-sheet coordination
  • Every remaining dimension, schedule, callout and companion detail needs region review; no accepted physical/world geometry.
  • Source-local applicability, construction thicknesses, complete object inventory and as-built correspondence remain unresolved.
  • Exact installed quantities and type-to-instance assignment
  • Rough/finished/structural endpoint classes, complete host outline and source-to-building registration
  • Governing original/revision and companion-detail authority; no accepted physical geometry
  • All uninspected source regions, notes, schedules and companion details; whole source remains partial
  • Accepted finish/rough/structural endpoint classes and source-to-building transform absent
  • All physical construction layers, exact material limits, installed quantities and as-built correspondence unresolved
  • Remaining fine chains, schedules, callouts, revisions and companion details require review; exhaustive extraction not certified
  • Classified finish/rough/structural faces, closed boundaries and source-to-building registration
  • Original/revision authority, companion details and as-built correspondence
  • All unreviewed regions, notes, schedules and callouts; no whole-source completeness
  • Full basement room/opening dimensions, boundaries and levels remain unresolved; no generic glyph can close these.
  • Accepted source-to-building transform and like-for-like finished/rough/structural face classification
  • Exact closed slab opening, landing perimeter and headroom
  • Construction/rail/nosing detail and revision/as-built reconciliation
  • All remaining unreviewed regions, notes, schedules and companion details

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Blue: printed controls. Gold: provisional geometry. Pink: held-out check residuals. An overlay is a comparison, not certification. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

759 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

b-elevator-3illegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: ELEVATOR No.3

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-dumbwaiterillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: DUMB WAITER

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-stackillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: Stack/chimney enclosure

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-coal-chuteillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: Coal-chute / service enclosure

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-stair-aillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: STAIR A

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-stair-cillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: STAIR C

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-stair-eillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: STAIR E

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-stair-hillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: STAIR H

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-stair-averified · printed

up-riser-count

UP22R

22 count

Visible marked flight only; do not infer tread, riser height or connected level from count.

IMG_1200 · Locate on drawing ↗

Drawing notation: STAIR A

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-stair-cverified · printed

up-riser-count

UP22R

22 count

Visible marked flight only; do not infer tread, riser height or connected level from count.

IMG_1200 · Locate on drawing ↗

Drawing notation: STAIR C

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-toilet-entry-level-changeillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: Swing-room / toilet entry level-change candidate

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-oil-tank-locationillegible · observed

clear-height

Not read

Numeric value unresolved

IMG_1200 · Locate on drawing ↗

Drawing notation: OIL TANK

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-3-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.115 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-4-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.763 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-5-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.907 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-6-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.052 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-16-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.881 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-17-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.303 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-13-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.238 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-14-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.95 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-15-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.747 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-18-corridor-northunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.96 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-18-corridor-southunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.005 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-19-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.674 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-20-corridor-northunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.114 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-20-corridor-southunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.015 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-21-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.491 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-22-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.559 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-23-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.991 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-24-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.991 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-25-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.983 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-foyer-lobbyunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.366 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-lobby-corridorunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

3.934 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-door-26-accessunreviewed · traced

opening-width-trace

Width from provisional traced jamb interval

4.488 ft · estimated uncertainty ±1.25 ft

IMG_1200 · Locate on drawing ↗

Drawing notation: Visible door leaf and swing

Manual source location in the explicitly stated upright reference. Metric geometry is a provisional trace, not a printed dimension.

b-stair-cverified · observed

flight_host_sides

[flight strips at page-bottom and page-right of ELEVATOR NO.2]

Unsigned plan directions: horizontal strip lies Main/north/page-bottom of Elevator2; perpendicular strip lies Broadway/west/page-right. Source-side relationship only, without a fitted transform.

IMG_1200 · Locate on drawing ↗

Drawing notation: [flight strips at page-bottom and page-right of ELEVATOR NO.2]

Unsigned plan directions: horizontal strip lies Main/north/page-bottom of Elevator2; perpendicular strip lies Broadway/west/page-right. Source-side relationship only, without a fitted transform.

b-stair-cunreviewed · observed

signed_ascent_path

UP 22R [arrow path requires endpoint review]

Do not infer signed three-dimensional path from strip axes; individual arrowheads and landing junctions need independently reviewed enlarged source. Prior verified count is reused, not duplicated.

IMG_1200 · Locate on drawing ↗

Drawing notation: UP 22R [arrow path requires endpoint review]

Do not infer signed three-dimensional path from strip axes; individual arrowheads and landing junctions need independently reviewed enlarged source. Prior verified count is reused, not duplicated.

b-elevator-2verified · printed

horizontal_local_plan_witness

7'-5½"

89.5 in

Printed local horizontal shaft-region witness only; finish/rough/inside/outside endpoints not classified, so not an accepted clear shaft width.

IMG_1200 · Locate on drawing ↗

Drawing notation: 7'-5½"

Printed local horizontal shaft-region witness only; finish/rough/inside/outside endpoints not classified, so not an accepted clear shaft width.

b-stair-cunreviewed · observed

physical_clear_width

Unresolved

Numeric value unresolved

No securely classified printed clear-width witness established by this crop.

IMG_1200 · Locate on drawing ↗

No securely classified printed clear-width witness established by this crop.

View all source photographs →