Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
door-img1126-later-head-jambverified · printed
later_sill_lockwasher_relationship
NUT & LOCK WASHERS ON BOTH SIDESReadable washer relationship within sill bolt note; no numerical quantity or bolt size inferred.
door-img1126-later-head-jambverified · printed
later_sill_metal_fascia_gauge
14 GAUGE METAL FACIA14 gauge
Gauge note leader at sill underside; metal type unspecified, no thickness conversion.
door-img1126-later-head-jambverified · printed
later_sill_metal_fascia_material
14 GAUGE METAL FACIAPrinted generic metal fascia; do not assign steel solely from nearby head fascia.
door-img1126-later-head-jambunreviewed · printed
elevator3_sill_exception_material
[NOTE: SILL AT ELEV.3 AT DOOR ...] ANTI-SLIP ALUMINUMReadable aluminum material in jamb note; intervening floor/door applicability phrase remains unresolved, so no floor assignment.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: [NOTE: SILL AT ELEV.3 AT DOOR ...] ANTI-SLIP ALUMINUM
Readable aluminum material in jamb note; intervening floor/door applicability phrase remains unresolved, so no floor assignment.
door-img1126-later-head-jambverified · printed
elevator3_first_floor_sill_material_exception
NOTE: SILL AT ELEV. 3 AT 1ST FL. TO BE ANTI-SLIP ALUMINUMSame original printed jamb/sill note as elevator1013p-1129-017. The phrase is1ST FL., not a door-number or unassigned floor. Resolves this note's material and first-floor applicability only; no installation, alloy, surface pattern, dimensions or revision choice.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: NOTE: SILL AT ELEV. 3 AT 1ST FL. TO BE ANTI-SLIP ALUMINUM
Same original printed jamb/sill note as elevator1013p-1129-017. The phrase is1ST FL., not a door-number or unassigned floor. Resolves this note's material and first-floor applicability only; no installation, alloy, surface pattern, dimensions or revision choice.
door-img1126-later-head-jambverified · printed
shared_enclosure_applicability_elevators_1_2
TYPICAL DETAIL OF ELEVATOR ENCLOSURE FOR ELEVATORS #1 & #2 FOR BASEMENT,2ND TO5TH FLOORS(INCLUSIVE),AND FOR7TH FLOORShared later enclosure applies to these explicitly printed levels for elevators1/2. First-floor and sixth-floor details remain separate variants.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: TYPICAL DETAIL OF ELEVATOR ENCLOSURE FOR ELEVATORS #1 & #2 FOR BASEMENT,2ND TO5TH FLOORS(INCLUSIVE),AND FOR7TH FLOOR
Shared later enclosure applies to these explicitly printed levels for elevators1/2. First-floor and sixth-floor details remain separate variants.
door-img1126-later-head-jambverified · printed
shared_enclosure_applicability_elevator_3
ALSO FOR ELEVATOR #3 FOR BASEMENT TO7TH FLOORS INCLUSIVEPrinted type applicability includes Elevator3 basement through7; no evidence that1/2 first- or sixth-floor variant also applies to3.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: ALSO FOR ELEVATOR #3 FOR BASEMENT TO7TH FLOORS INCLUSIVE
Printed type applicability includes Elevator3 basement through7; no evidence that1/2 first- or sixth-floor variant also applies to3.
door-img1126-later-head-jambverified · printed
sill_anchor_field_drilling_note
DRILL ANCHORS IN FIELDField drilling note in common sill section; hole/anchor sizes, spacing and installed stations unresolved.
door-img1126-later-head-jambverified · printed
sill_anchor_to_steel_beam_relationship
BENT ANGLE ANCHORS TO STEEL I BEAM IN AN APPROVED MANNER [size prefix unresolved]Anchor is related to structural steel I-beam in common sill section. Approved manner is not an extracted fastening specification; size prefix withheld.
IMG_1129 · W-229 · Locate on drawing ↗Drawing notation: BENT ANGLE ANCHORS TO STEEL I BEAM IN AN APPROVED MANNER [size prefix unresolved]
Anchor is related to structural steel I-beam in common sill section. Approved manner is not an extracted fastening specification; size prefix withheld.