Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
door-img1126-later-head-jambverified · printed
marble_applicability_exception
MARBLE OCCURS ELEV. #1 AT BASMT.Leader beside later head/jamb: an explicit material applicability statement, not a blanket marble assignment to all elevator enclosures.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: MARBLE OCCURS ELEV. #1 AT BASMT.
Leader beside later head/jamb: an explicit material applicability statement, not a blanket marble assignment to all elevator enclosures.
door-img1126-later-head-jambverified · printed
head_plate_and_buck_material
NICK. STEEL PLATE & BUCKPreserves printed abbreviation NICK.; no alloy, finish process, gauge or installed floor range inferred.
door-img1126-later-head-jambunresolved · printed
head_plate_thickness
[fraction before NICK. STEEL PLATE & BUCK unresolved]Numeric value unresolved
Fine fraction remains unreadable in existing master crop. Preserve null rather than accepting a nominal plate gauge.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: [fraction before NICK. STEEL PLATE & BUCK unresolved]
Fine fraction remains unreadable in existing master crop. Preserve null rather than accepting a nominal plate gauge.
door-img1126-later-head-jambverified · printed
later_head_nickel_steel_plate_thickness_resolution
3/16″ STEEL NICKEL PLATE & BUCK0.1875 in
Fraction belongs to later head plate-and-buck leader; original photographic layer only. Does not establish alloy, nickel process, installed thickness or applicability beyond the separate printed caption.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: 3/16″ STEEL NICKEL PLATE & BUCK
Fraction belongs to later head plate-and-buck leader; original photographic layer only. Does not establish alloy, nickel process, installed thickness or applicability beyond the separate printed caption.
Calculated from: door-20261012p-1126-m007
w229-machine-room-section-eeverified · printed
source_section_designation
SECTION E-EPrinted section identifier only; no geometric registration.
w229-machine-room-section-eeverified · printed
acoustical_treatment_scope
ACOUSTICAL TREATMENT ON WALLS AND CEILINGTreatment applies to machine-room walls and ceiling as printed. Product, thickness, finish and installation extents unspecified.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: ACOUSTICAL TREATMENT ON WALLS AND CEILING
Treatment applies to machine-room walls and ceiling as printed. Product, thickness, finish and installation extents unspecified.
w229-machine-room-section-eeverified · printed
roof_insulation_label
INSULATIONLeader identifies insulation at the top of the sectioned machine-room roof assembly. No material, thickness or full envelope extent established.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: INSULATION
Leader identifies insulation at the top of the sectioned machine-room roof assembly. No material, thickness or full envelope extent established.
w229-machine-room-section-eeverified · printed
machine_room_floor_elevation_glyph
EL. 195.00195 unlabeled
Numeric EL glyph at machine-room floor in section E-E. No unit marks certified; not feet, global elevation, benchmark or adopted storey datum.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: EL. 195.00
Numeric EL glyph at machine-room floor in section E-E. No unit marks certified; not feet, global elevation, benchmark or adopted storey datum.
w229-sheave-service-landing-eeverified · printed
sheave_service_landing_elevation_glyph
EL. 190.08190.08 unlabeled
Numeric EL glyph at lower sheave-service landing in same section. Unit convention unestablished; no elevation difference calculated.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: EL. 190.08
Numeric EL glyph at lower sheave-service landing in same section. Unit convention unestablished; no elevation difference calculated.
w229-machine-room-elevator-contractor-beamsverified · printed
beam_furnishing_responsibility
NOTE: THESE BEAMS TO BE FURNISHED BY THE ELEVATOR CONTRACTORSection E-E note assigns furnishing of indicated beams to elevator contractor. Does not specify alloy, section sizes, installed count or fabrication/connection method.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: NOTE: THESE BEAMS TO BE FURNISHED BY THE ELEVATOR CONTRACTOR
Section E-E note assigns furnishing of indicated beams to elevator contractor. Does not specify alloy, section sizes, installed count or fabrication/connection method.
w229-machine-room-iron-ladder-planverified · printed
ladder_material_designation
IRON LADDERPrinted plan leader identifies ladder as iron; dimensions, rungs, fastening and installed extent remain unestablished.
w229-machine-room-fire-door-planverified · printed
door_type_designation
FIRE DOORPrinted plan designation of machine-room access door. No certified fire rating, nominal size, operating clear opening or material inferred.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: FIRE DOOR
Printed plan designation of machine-room access door. No certified fire rating, nominal size, operating clear opening or material inferred.
w229-machine-room-clear-hatch-below-planverified · printed
hatch_vertical_relation
CLEAR HATCH BELOWMachine-room plan identifies clear hatch below. Drawn crossed enclosure and label supply source-local vertical relation only; no accepted shaft transform.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: CLEAR HATCH BELOW
Machine-room plan identifies clear hatch below. Drawn crossed enclosure and label supply source-local vertical relation only; no accepted shaft transform.
w229-machine-room-ci-threshold-planverified · printed
threshold_type_literal
C.I. THRESHOLDLiteral abbreviated threshold designation beside machine-room plan fire door. Adjacent SEE DETAIL SHEET reference number is not certified; abbreviation is preserved without alloy expansion.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: C.I. THRESHOLD
Literal abbreviated threshold designation beside machine-room plan fire door. Adjacent SEE DETAIL SHEET reference number is not certified; abbreviation is preserved without alloy expansion.
door-img1126-steel-trap-detailverified · printed
elevator_2_companion_sheet_reference
FOR DETAIL OF ELEVATOR NO.2 — SEE SH.230Printed companion reference selects Elevator2 detail sheet230; separate elevator identity from Elevator1 layout.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: FOR DETAIL OF ELEVATOR NO.2 — SEE SH.230
Printed companion reference selects Elevator2 detail sheet230; separate elevator identity from Elevator1 layout.
door-img1126-steel-trap-detailverified · printed
elevator_3_companion_sheet_reference
FOR DETAIL OF ELEVATOR NO.3 — SEE SH.231Printed companion reference selects Elevator3 detail sheet231; no dimension borrowed from1/2.
door-img1126-first-floor-headverified · printed
first_floor_head_horizontal_projecting_witness
1′-0″12 in
Independent horizontal witness above projecting head section. Source witness ends are visible, but exact equipment/finished-opening face classes remain unresolved. Not door clear width.
IMG_1126 · W-229 · Locate on drawing ↗Drawing notation: 1′-0″
Independent horizontal witness above projecting head section. Source witness ends are visible, but exact equipment/finished-opening face classes remain unresolved. Not door clear width.