Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · observed
finished screen, pier and head top local Y by segment
UnresolvedNumeric value unresolved
unresolved: screen meets overhead plaster/beam zone, with no accepted finished top height for every segment. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-door-main-foyer-public-centerunreviewed · observed
paired-door finished head local Y
UnresolvedNumeric value unresolved
unresolved; ornamental band is visible but its lower/upper finished elevations are not securely read. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-door-main-foyer-public-centerunreviewed · observed
upper fixed-glazing/transom bottom local Y
UnresolvedNumeric value unresolved
unresolved. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-door-main-foyer-public-centerunreviewed · observed
upper fixed-glazing/transom top local Y
UnresolvedNumeric value unresolved
unresolved. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-main-foyer-public-lobby-screen-assemblyunreviewed · observed
solid pier/return finished depth at Bay U
UnresolvedNumeric value unresolved
unresolved: drawn depth layers cannot be equated to one continuous two-face wall depth. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
f1-door-main-foyer-public-westunreviewed · observed
Bay T finished sill local Y
BAYS T & V SIMILARNumeric value unresolved
unresolved: no checked Bay T datum. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-westunreviewed · observed
Bay T finished door-head local Y
BAYS T & V SIMILARNumeric value unresolved
unresolved: no checked Bay T dimension endpoints. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-westunreviewed · observed
Bay T upper fixed-glazing bottom local Y
BAYS T & V SIMILARNumeric value unresolved
unresolved: no checked Bay T dimension endpoints. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-westunreviewed · observed
Bay T upper fixed-glazing top local Y
BAYS T & V SIMILARNumeric value unresolved
unresolved: no checked Bay T dimension endpoints. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-westunreviewed · observed
Bay T finished foyer-to-lobby jamb depth
BAYS T & V SIMILARNumeric value unresolved
unresolved: no finished face pair or W3 registration. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-eastunreviewed · observed
Bay V finished sill local Y
BAYS T & V SIMILARNumeric value unresolved
unresolved: no checked Bay V datum. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-eastunreviewed · observed
Bay V finished door-head local Y
BAYS T & V SIMILARNumeric value unresolved
unresolved: no checked Bay V dimension endpoints. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-eastunreviewed · observed
Bay V upper fixed-glazing bottom local Y
BAYS T & V SIMILARNumeric value unresolved
unresolved: no checked Bay V dimension endpoints. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-eastunreviewed · observed
Bay V upper fixed-glazing top local Y
BAYS T & V SIMILARNumeric value unresolved
unresolved: no checked Bay V dimension endpoints. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
f1-door-main-foyer-public-eastunreviewed · observed
Bay V finished foyer-to-lobby jamb depth
BAYS T & V SIMILARNumeric value unresolved
unresolved: no finished face pair or W3 registration. Typological similarity and component identity do not authorize physical extrusion or W3 placement.
Calculated from: gate-w217-w218-foyer-lobby-screen-vertical-depth-gate-utv-similar-elevation-type
w3-public-lobby-bay-uunreviewed · observed
finished transverse thickness by solid, jamb and glazed segment
UnresolvedNumeric value unresolved
Bay identity/printed rhythm only; no accepted wall face, opening, thickness or vertical bound.
IMG_1095 · sheet-W217 · View drawing ↗Drawing notation: Unresolved physical bound
unresolved; no matching finished face pair or W3 registration; prior direct-inspection text package; source not reopened
Calculated from: north-u-lobby-finished-face-z, north-u-foyer-finished-face-z
f1-door-main-foyer-public-centerunreviewed · inferred
finished paired-door opening width
UnresolvedNumeric value unresolved
Bay identity/printed rhythm only; no accepted wall face, opening, thickness or vertical bound.
Calculated from: north-u-finished-jamb-x
f1-door-main-foyer-public-centerunreviewed · inferred
finished door-head local Y
UnresolvedNumeric value unresolved
Bay identity/printed rhythm only; no accepted wall face, opening, thickness or vertical bound.
parallel-img1095-directoryverified · printed
door-and-lock-callout
LOCKING DEVICE / KEY THIS SIDE OF THE GLASSSource-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established.
IMG_1095 · W-217 · Locate on drawing ↗Drawing notation: LOCKING DEVICE / KEY THIS SIDE OF THE GLASS
Source-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established.
parallel-img1095-sectionunreviewed · printed
unresolved-depth-chain
[Section E-E fine depth and profile dimensions unresolved]Numeric value unresolved
Source-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established.
IMG_1095 · W-217 · Locate on drawing ↗Drawing notation: [Section E-E fine depth and profile dimensions unresolved]
Source-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established.
closure1011u-img1095-elevator-eeverified · observed
section_e_e_view_association
E / SECTION E-EE markers on the elevator elevation identify the upper-right Section E-E as an elevator-door construction companion. Earlier generic Bay P Section E-E target does not justify assigning this section to the directory cabinet. This closes source-view association only; depth remains null.
IMG_1095 · W-217 · Locate on drawing ↗Drawing notation: E / SECTION E-E
E markers on the elevator elevation identify the upper-right Section E-E as an elevator-door construction companion. Earlier generic Bay P Section E-E target does not justify assigning this section to the directory cabinet. This closes source-view association only; depth remains null.
closure1011u-img1095-elevator-eeverified · printed
face_plate_gauge_number
#14 GAUGE FACE PLATES14 gauge
Lower Section E-E printed callout. Gauge number only; gauge standard, thickness and alloy are not established.
closure1011u-img1095-elevator-eeunreviewed · observed
section_e_e_depth_chain
[small head and sill depth-chain tokens/endpoints unresolved]Numeric value unresolved
Master section and tighter head crops do not securely establish numerical depth with front/back witness endpoints. No value transferred from plan chain or elevation face width.
IMG_1095 · W-217 · Locate on drawing ↗Drawing notation: [small head and sill depth-chain tokens/endpoints unresolved]
Master section and tighter head crops do not securely establish numerical depth with front/back witness endpoints. No value transferred from plan chain or elevation face width.
closure1011u-img1095-elevator-plan-supportverified · printed
support_continuity_and_anchor_relationship
[size unresolved] L CONTINUOUS FROM 1ST TO 2ND FLOOR. SECURELY TO BE ANCHORED TO STRUCTURAL FRAME.Plan note immediately below elevator entrance describes vertical continuity and connection to structural frame. Initial member size remains unresolved; no anchor or installed member geometry inferred.
IMG_1095 · W-217 · Locate on drawing ↗Drawing notation: [size unresolved] L CONTINUOUS FROM 1ST TO 2ND FLOOR. SECURELY TO BE ANCHORED TO STRUCTURAL FRAME.
Plan note immediately below elevator entrance describes vertical continuity and connection to structural frame. Initial member size remains unresolved; no anchor or installed member geometry inferred.
closure1011u-img1095-elevator-eeverified · printed
section_astragal_construction
CAST ASTRAGALReadable middle/lower Section E-E callout identifies cast astragal only. Exact depth-chain question remains null; this noun is not a depth closure. Installed instance mapping, world placement, companion/revision authority and whole-building acceptance remain unresolved.
IMG_1095 · W-217 · Locate on drawing ↗Drawing notation: CAST ASTRAGAL
Readable middle/lower Section E-E callout identifies cast astragal only. Exact depth-chain question remains null; this noun is not a depth closure. Installed instance mapping, world placement, companion/revision authority and whole-building acceptance remain unresolved.