Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_0991 · Folder 193

1186%+2X10"Wi̇ndowai

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial first-pass visual review of public/archive/drawings/complete-upright/IMG_0991.webp after catalogue and OCR. Coordinates are normalized access-image coordinates before any rotation. Actual access image requires 0 degrees rotation to read. Selected evidence only; no geometry/modeling inference. Cropped companion sheets visible behind foreground drawing are excluded. Partial timed visual review: undefined Partial timed visual review: Bounded hardware, profile and support note review; no building placement or accepted geometry. Partial timed visual review: Source-local depicted assembly or specification only. No installed quantities, accepted floor geometry or model placement inferred. Partial timed visual review: Source-local fabrication detail and bill only; installed occurrence and revision authority remain unresolved. Partial timed visual review: Depicted type/component, shop order or source-local assembly only. Components and grille order quantities do not create installed fixtures or establish electrical outlet-to-type assignments.

Unresolved extraction work
  • Complete small-dimension and callout transcription
  • Review handwritten revisions and faint annotations
  • Identify all instances and companion detail relationships
  • Register detail geometry against building locations
  • Installed instances, quantities and source-to-building registration remain unestablished.
  • Complete dimensions, machining profiles, companion sheets and governing revision authority remain open.
  • Remaining section and profile dimensions and witness endpoints
  • Companion revision authority, installed instance registration and quantities
  • Remaining fine dimensions and handwritten revisions require targeted higher-resolution evidence
  • Companion registration and physical instance mapping remain unresolved
  • Remaining profile chains and full machining details
  • Companion/revision authority and physical registration
  • Remaining fine fractions, outline profiles, machining endpoints and marginal handwriting require targeted master review.
  • Full companion and revision authority audit remains open.
  • Installed instance quantities, room/floor placement, hosts and source-to-building registration are unestablished.
  • Existing sectionreadings reused text-only; crop didnot re-inspect sections. Fine profiles remain open.
  • Selected enlargedcrop resolves⅜CSK andditto parent. Right continuation andmaterial/WT columns clipped.6⅛lengthclosedIDreused.
  • Known31shoporder retained separately frominstalledcount. Layout outsidecrop reused text-only, no whole-sourcereview claim.
  • Fullbill continuation andsame-sheet revisions remainopen.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

51 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img0991-fasteningverified · printed

grille_order_quantity

31 grilles required

31 count

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 31 grilles required

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

top_section_quantity

31 top section with pickets

31 count

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 31 top section with pickets

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

bottom_section_quantity

31 bottom section

31 count

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 31 bottom section

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

intermediate_section_quantity

124 intermediate sections

124 count

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 124 intermediate sections

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

rosette_order_quantity

3720 rosettes

3720 count

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 3720 rosettes

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

shipment_date

Shipped Aug. 12th 1932

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: Shipped Aug. 12th 1932

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

bolt_diameter

⅝ bolt

0.625 in

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: ⅝ bolt

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

bolt_end_specification

Peen ends of bolts after grilles are assembled on job

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: Peen ends of bolts after grilles are assembled on job

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

bar_connection

Weld bars together

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: Weld bars together

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

machine_screw_diameter

5/16 × 1¼ machine screws

0.3125 in

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 5/16 × 1¼ machine screws

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

machine_screw_length

5/16 × 1¼ machine screws

1.25 in

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 5/16 × 1¼ machine screws

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

machine_screw_drilling

Do not drill thru

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: Do not drill thru

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

groove_omission

Omit groove on back side of side bars in way of all six masonry fastenings

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: Omit groove on back side of side bars in way of all six masonry fastenings

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

fastenings_per_side

3 fastenings to masonry on each side of opening

3 count

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 3 fastenings to masonry on each side of opening

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

section_BB_scale

6" = 1 ft

6 in/ft

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: 6" = 1 ft

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

parallel-img0991-fasteningverified · printed

section_AA_scale

Full size

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

IMG_0991 · Locate on drawing ↗

Drawing notation: Full size

Selected visible printed or handwritten source evidence; partial review. Detail/type-level property only; do not infer an installed room geometry or count from photograph repetition.

closure1011aa-img0991-masonry-anchorverified · printed

anchor_bar_masonry_projection

4"

4 in

Source-local detail only. Dimension extends from masonry-face line to dashed anchor end; no embedment derived from photo scale.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 4"

Source-local detail only. Dimension extends from masonry-face line to dashed anchor end; no embedment derived from photo scale.

closure1011aa-img0991-aa-memberverified · printed

section_depth

1⅜"

1.375 in

Source-local detail only. Witness lines bound front/back member faces above A-A; profile layer widths remain open.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 1⅜"

Source-local detail only. Witness lines bound front/back member faces above A-A; profile layer widths remain open.

closure1011aa-img0991-bb-anchorverified · printed

bracket_to_bolt_center_offset

1½"

1.5 in

Source-local detail only.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 1½"

Source-local detail only.

closure1011aa-img0991-masonry-anchorverified · printed

bill_masonry_anchor_thickness

186 ½ × 2" × 6⅜ [length candidate] MASONRY ANCHORS

0.5 in

Source-local detail only. Thickness token ½ is legible in bill; length fraction remains provisional.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 186 ½ × 2" × 6⅜ [length candidate] MASONRY ANCHORS

Source-local detail only. Thickness token ½ is legible in bill; length fraction remains provisional.

closure1011aa-img0991-masonry-anchorunreviewed · printed

bill_masonry_anchor_length_candidate

6⅜ [fraction candidate]

6.375 in

Source-local detail only. Bill length fraction needs cleaner source evidence; not accepted. Review correction review-correction-20261013j-closure1011aa-img991-bill-anchor-length: The crop of the same IMG_0991 bill row reads 6 1/8 in, confirming the existing verified reread and disproving the earlier 6 3/8 candidate. Retain the previous candidate as a review trail.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 6⅜ [fraction candidate]

Source-local detail only. Bill length fraction needs cleaner source evidence; not accepted.

closure1011aa-img0991-window-anchorverified · printed

bill_window_anchor_thickness

186 ⅞ × 2" × 10" WINDOW ANCHORS

0.875 in

Source-local detail only.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 186 ⅞ × 2" × 10" WINDOW ANCHORS

Source-local detail only.

closure1011aa-img0991-window-anchorverified · printed

bill_window_anchor_length

10"

10 in

Source-local detail only.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 10"

Source-local detail only.

closure1011aa-img0991-countersunk-screwunreviewed · printed

countersunk_screw_diameter_detail_candidate

⅜" × 2" CSK. SCREWS

0.375 in

Source-local detail only. Detail appears ⅜ whereas bill clearly prints ⅞; preserve separate readings pending fabrication authority.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: ⅜" × 2" CSK. SCREWS

Source-local detail only. Detail appears ⅜ whereas bill clearly prints ⅞; preserve separate readings pending fabrication authority.

closure1011aa-img0991-countersunk-screwunreviewed · printed

countersunk_screw_diameter_bill

620 ⅞ × 2" CSK. SCREWS

0.875 in

Source-local detail only. Bill reading retained separately from A-A candidate; no choice of installed fastener. Review correction review-correction-20261013j-closure1011aa-img991-bill-screw-diameter: The enlarged crop of the same IMG_0991 bill row reads 3/8 in, not 7/8 in. Numerator 3 is distinct; the unchanged 620-piece CSK row and 2 in length establish the same scope.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 620 ⅞ × 2" CSK. SCREWS

Source-local detail only. Bill reading retained separately from A-A candidate; no choice of installed fastener.

parallel-img0991-fasteningverified · printed

slotted-hole-width

11/16 × 15/16 SLOTTED HOLES

0.6875 in

Source-local depicted assembly or specification only. No installed quantities, accepted floor geometry or model placement inferred.

IMG_0991 · Locate on drawing ↗

Drawing notation: 11/16 × 15/16 SLOTTED HOLES

Source-local depicted assembly or specification only. No installed quantities, accepted floor geometry or model placement inferred.

parallel-img0991-fasteningverified · printed

slotted-hole-length

11/16 × 15/16 SLOTTED HOLES

0.9375 in

Source-local depicted assembly or specification only. No installed quantities, accepted floor geometry or model placement inferred.

IMG_0991 · Locate on drawing ↗

Drawing notation: 11/16 × 15/16 SLOTTED HOLES

Source-local depicted assembly or specification only. No installed quantities, accepted floor geometry or model placement inferred.

closure1011aa-img0991-countersunk-screwverified · printed

countersunk_screw_diameter_detail_reread

⅜" × 2" CSK. SCREWS

0.375 in

Readable master hardware crop confirms numerator 3 and denominator 8 in A-A callout. Confirms previous candidate without choosing installed fastener.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: ⅜" × 2" CSK. SCREWS

Readable master hardware crop confirms numerator 3 and denominator 8 in A-A callout. Confirms previous candidate without choosing installed fastener.

closure1011aa-img0991-countersunk-screwverified · printed

countersunk_screw_length_detail

⅜" × 2" CSK. SCREWS

2 in

Second size token in A-A screw callout; no thread or installed occurrence inferred.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: ⅜" × 2" CSK. SCREWS

Second size token in A-A screw callout; no thread or installed occurrence inferred.

closure1011aa-img0991-countersunk-screwunreviewed · printed

countersunk_screw_diameter_bill_reread_candidate

620 ⅜ [numerator reread candidate] × 2" CSK. SCREWS

0.375 in

Master bill crop suggests numerator 3 rather than earlier 7. Lower numerator stroke is curved; this is a competing reread, not a silent replacement. Keep prior 0.875 reading and unresolved conflict until independent review confirms glyph.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 620 ⅜ [numerator reread candidate] × 2" CSK. SCREWS

Master bill crop suggests numerator 3 rather than earlier 7. Lower numerator stroke is curved; this is a competing reread, not a silent replacement. Keep prior 0.875 reading and unresolved conflict until independent review confirms glyph.

closure1011aa-img0991-masonry-anchorverified · printed

bill_masonry_anchor_length_reread

186 ½ × 2" × 6⅛ MASONRY [right continuation clipped]

6.125 in

Master bill crop clearly shows single vertical numerator 1 over denominator 8 following 6. Supersedes prior unreviewed 6⅜ candidate as a source reading; historic record retained. No geometry acceptance implied.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 186 ½ × 2" × 6⅛ MASONRY [right continuation clipped]

Master bill crop clearly shows single vertical numerator 1 over denominator 8 following 6. Supersedes prior unreviewed 6⅜ candidate as a source reading; historic record retained. No geometry acceptance implied.

closure1011aa-img0991-countersunk-screwverified · printed

bill_screw_diameter_verified_reread

620 ⅜" × 2" CSK. SCREWS

0.375 in

Depicted type/component or shop-order row only; no installed quantity or accepted physical geometry. Enlarged crop clearly separates numerator 3 and denominator 8; same bill row as earlier⅞ transcription.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: 620 ⅜" × 2" CSK. SCREWS

Depicted type/component or shop-order row only; no installed quantity or accepted physical geometry. Enlarged crop clearly separates numerator 3 and denominator 8; same bill row as earlier⅞ transcription.

Conflicting readings: closure1011aa-img991-bill-screw-diameter hardware1012s-991-bill-screw-diameter-reread

closure1011aa-img0991-countersunk-screwverified · printed

bill_screw_type

CSK. SCREWS

Depicted type/component or shop-order row only; no installed quantity or accepted physical geometry. Governing text for following ditto row.

IMG_0991 · 640 · Locate on drawing ↗

Drawing notation: CSK. SCREWS

Depicted type/component or shop-order row only; no installed quantity or accepted physical geometry. Governing text for following ditto row.

View all source photographs →